PubMed Health⌕ Search

Biomedical subjects

M C Graham

Publications and source records attributed to M C Graham.

58 records · Page 4Linked to original sources

Doubly tuned solenoidal resonators for small animal imaging and spectroscopy at 1.5 Tesla.

The design and construction of solenoidal resonators for use with small animals in a 1.5-Tesla clinical imaging system are described. The coils have been designed to exploit the B1 distributions of two resonant modes of a four-turn solenoid whose windings are in parallel. Both singly and doubly tuned versions have been constructed. 1H images of normal and pathologic anatomy in mice and rats as well as a 31P spectrum of a Walker 256 rat sarcoma are presented. A primary advantage of this design is that the coils are easy to build and implement while providing the necessary sensitivity to allow high quality images to be obtained with no changes to the hardware or software of the clinical unit.

Animals↗

Postnatal development of brainstem auditory-evoked potentials, electroretinograms, and visual-evoked potentials in the calf.

Brainstem auditory-evoked potentials (BAEP), electroretinograms (ERG), and visual-evoked potentials (VEP) were recorded for eight calves from birth to 56 days and the values compared with previously determined adult responses. The BAEPs, ERGs, and VEPs recorded within the first 24 hours after birth contained all of the peaks seen in adult recordings. Varying degrees of maturation of the responses were documented as changes in latency and amplitude with age. The BAEPs were adult-like at birth, with latencies falling within the mean, plus or minus one standard deviation, for adult cows. A small but significant decrease in latency with age was seen for the first, second, and fourth peaks of the response. The ERG amplitudes were also within the adult range for the entire period of the study. Latencies to the a- and b-waves declined during the first 14 days and then stabilized at adult values. The VEP latencies decreased with age, with late peaks changing more than early peaks. Latencies of all but the first peak decreased to values less than the adult range. Two VEP amplitudes increased significantly with age. Developmental appears in the calf and other precocious species are compared to those in altricious (nonprecocious) species.

Animals↗

Brainstem auditory-evoked potentials in Holstein cows.

Brainstem auditory-evoked potentials (BAEP) were recorded from 29 Holstein cows in a typical clinical setting. The latencies of five positive peaks in the BAEP were measured, and latency-intensity functions were determined. The BAEP was similar to that reported in humans, dogs, horses, and other species. The responses were reproducible for each cow, with low variability between cows. Four peaks (I, II, III, V) were present in all recordings, and a fifth (IV) was present infrequently. All peak latencies decreased as click-stimulus intensity increased. The threshold for detection of the BAEP was higher than expected for the cow compared with the horse.

Animals↗

Quantitative imaging of I-124 using positron emission tomography with applications to radioimmunodiagnosis and radioimmunotherapy.

Positron emission tomography (PET) is potentially useful for the quantitative imaging of radiolabeled antibodies, leading in turn to improved dosimetry in radioimmunotherapy. Iodine-124 is a positron-emitting nuclide with appropriate chemical properties and half-life (4.2 days) for such studies since the radiolabeling of antibodies with iodine is well understood and the half-life permits measurements over several days. Unfortunately, I-124 has a complex decay scheme with many high-energy gamma rays and a positron abundance of only 25%. It has therefore been largely ignored as a PET-imaging nuclide. However, measurements made with phantoms and animals under realistic conditions using a BGO-based PET scanner have shown that satisfactory imaging and quantitation can be achieved. Investigations of spatial resolution, the linearity of regional observed count rate versus activity in the presence of other activity, and the visualization and quantitation of activity in spheres with different surrounding background activities were carried out with phantoms up to 22 cm in diameter. Compared with F-18, spatial resolution was only slightly degraded (13.5 mm FWHM vs 12 mm FWHM) while linearity was the same over a 10:1 activity range (0.015 to 0.15 MBq/ml for I-124). The visualization and quantitation of spheres was also slightly degraded when using similar imaging times. Increasing the imaging time for I-124 reduced the difference. To verify that the technique would work in vivo, measurements were made of human neuroblastoma tumors in rats which had been injected with I-124 labeled 3F8 antibody. Although the number of samples was small, good agreement was achieved between image-based measurements and direct measurements of excised 4-g tumors. Thus quantitative imaging of I-124 labeled antibodies appears to be possible under realistic conditions.

Animals↗