M C Herregods

Publications and source records attributed to M C Herregods.

At least 19 recordsLinked to original sources

PET "reversed mismatch pattern" early after acute myocardial infarction: follow-up of flow, metabolism and function.

The aim of this study was to evaluate changes of flow, metabolism and left ventricular function in patients revealing a "reversed mismatch" pattern (reduced glucose uptake relative to perfusion) on positron emission tomography (PET) early after myocardial infarction. In 19 out of 68 patients (28%), prospectively included in the GUSTO-I or STAR studies, a PET reversed mismatch pattern in the infarct-related region was found. All patients received thrombolytic therapy within 3 h after onset of pain and coronary angiography 90 min later. 2-[18F]fluoro-2-deoxy-D-glucose (18F-FDG)/nitrogen-13-labelled ammonia (13NH3) PET was performed after 5 days and 3 months. In 12 of the 19 patients, functional recovery was investigated with two-dimensional echocardiography at the same time points. In the infarct-related region, normalized 13NH3 uptake was 76% +/- 11% at 5 days and 85% +/- 10% at 3 months (P < 0.00001). Absolute blood flow in this region was 75 +/- 25 ml/min per 100 g at 5 days and 80 +/- 19 ml/min per 100 g at 3 months. At 5 days, normalized 18F-FDG uptake in the infarct-related region was decreased (51% +/- 12%). At 3 months, 18F-FDG uptake in this region had significantly recovered (75% +/- 11%, P < 0.00001). In the infarct-related region, absolute FDG metabolism was 17 +/- 6 mumol/min per 100 g at 5 days and 26 +/- 9 mumol/min per 100 g at 3 months (P < 0.0001). At 5 days, normalized 18F-FDG uptake was more severely decreased as compared to the normalized 13NH3 uptake (P < 0.00001) in the infarct-related region, resulting in a reversed mismatch pattern (25% +/- 13% of the left ventricle). At 3 months, 18F-FDG metabolism had partially recovered, giving rise to a change into a PET match pattern. Reversed mismatch regions were present in only 7% +/- 7% of the left ventricle at that time. The ratio of 18F-FDG uptake to 13NH3 uptake in the infarct-related region increased from 0.67 +/- 0.8 at 5 days to 0.88 +/- 0.09 at 3 months (P < 0.00001). No functional recovery was observed in the infarct-related region (the 5-day and 3-month wall motion scores were both 2.5 +/- 0.5). In patients with a myocardial infarction showing a PET reversed mismatch pattern 5 days after thrombolytic therapy, recovery of 18F-FDG uptake was found but no functional recovery was observed at 3-month follow-up.

Acute Disease↗

Silzone coating and paravalvular leak: an independent, randomized study.

BACKGROUND AND AIM OF THE STUDY: The study aim was to address independently, in a randomized patient cohort, the impact of Silzone coating on the prevalence and impact of paravalvular leak in patients undergoing mechanical valve replacement. METHODS: Randomized implantation of the uncoated St. Jude Medical Masters, and the Silzone-coated prosthesis was performed in 95 patients, excluding those with suspected or diagnosed infective endocarditis. The company did not support the study; this cohort is not contained in the AVERT trial. Following recall of the Silzone-coated valves, all patients in this cohort were invited to undergo control transthoracic echocardiography and plasma LDH determination. RESULTS: Silzone-coated valves were implanted in 46 patients (57 valves; 34 aortic, 20 mitral, three tricuspid), and uncoated valves in 49 patients (55 valves; 38 aortic, 16 mitral, one tricuspid). One patient with an uncoated mitral valve died from left ventricular dissection. In total, 73 patients returned for specifically planned echocardiography (mean interval 478+/-78 days). Sixteen patients underwent echocardiography on another occasion (mean interval 113+/-202 days). Six hospital survivors did not undergo any postoperative echocardiography. In total, 51 Silzone-coated valves (31 aortic, 18 mitral, two tricuspid), and 53 uncoated valves (37 aortic, 15 mitral, one tricuspid) were evaluated. No patients were reoperated for intrinsic or extrinsic valve dysfunction. No major paravalvular leaks were seen. Five of 51 Silzone-coated valves showed minimal (grade <1+; four aortic, one mitral) paravalvular leak when specifically sought; two showed minimal (grade <1+; one aortic, one mitral), and one slight (grade 1+; one mitral) paravalvular leak in the uncoated group (p = 0.55). The LDH level was 654+/-163 U/I in the Silzone group, and 598+/-124 U/l in the control group (p = 0.10). CONCLUSION: No differences were detected in the incidence of paravalvular leak between Silzone-coated and uncoated mechanical St. Jude Medical valves. The incidence of major paravalvular leaks appears to be lower in the present cohort than was reported in the AVERT trial.

Aged↗

High frame rate myocardial integrated backscatter. Does this change our understanding of this acoustic parameter?

AIMS: Integrated backscatter (IB) and its cyclic variation (CV) derived from radio-frequency (RF) data have been used as parameters to attempt myocardial tissue characterization. Prior imaging systems used to measure IB and its CV typically acquired data at frame rates of 20-30 Hz and at a resolution of 6-8 bits. If changes in IB levels are in part related to specific short-lived events, occurring within the cardiac cycle, this frame rate and resolution could have been too low to resolve adequately what might be a more complex data set. METHODS AND RESULTS: To investigate this possibility, we acquired real time two-dimensional (2D) myocardial IQ data (the 'in-phase quadrature' sampled RF data) at high frame rate (> 100 Hz), high dynamic resolution (theoretical 19-bit) and a sector angle of 20 degrees. Several consecutive heart cycles of myocardial data were acquired from individual cardiac walls in five closed chest dogs and 10 healthy, young volunteers at normal heart rates. On the reconstructed RF data regions of interest were indicated, and IB and its CV were calculated. The extracted high frame rate curves showed that the CV of IB is not a smooth sinusoidal-like curve, but is made up of multiple reproducible peaks and troughs with local minima and maxima which are temporally related to active or passive mechanical events, i.e. systolic contraction, early ventricular relaxation and ventricular filling due to atrial contraction. CONCLUSIONS: This study shows that increasing the rate of real-time RF data acquisition results in a more complex, reproducible IB curve. The resolved maxima and minima in IB levels are related to specific phases of the myocardial contraction. Furthermore, spectral analysis showed that IB curves acquired at normal heart rates contain information up to 40 Hz. Hence, cardiac imaging data sets used to analyse regional myocardial function obtained at frequencies lower than 80 frames per second can contain aliased information.

Adult↗

Are changes in myocardial integrated backscatter restricted to the ischemic zone in acute induced ischemia? An in vivo animal study.

Integrated backscatter (IB) from a myocardial region, calculated from radiofrequency echocardiographic data, has been proposed as a useful parameter for investigating changes in myocardial tissue induced by ischemia. In 10 closed-chest dogs, 5 minutes of myocardial ischemia was induced by either a proximal occlusion of the circumflex coronary artery (CX) (5 dogs), resulting in extensive ischemia in the posterior wall, or by occluding the distal CX vessel (5 dogs) to produce a small localized ischemic zone in the posterior wall. High-resolution digital radiofrequency data from the whole left ventricular myocardium, in the imaging plane during one complete heart cycle, were acquired with a whole-image real-time acquisition approach. Regions in the septum and posterior wall (both ischemic tissue and, in the case of distal occlusions, tissue surrounding the ischemic zone) were chosen for analysis, and IB and cyclic variation (CV) of IB were calculated. Post occlusion, an increase in mean IB values was found in the ischemic segment. However, an increase in CV was also observed in the peri-ischemic zone for the distal CX occlusion and in the septum after proximal CX occlusion. These findings show that changes in CV are not restricted to the ischemic zone but may also occur in distal myocardium. This may be explained by changes in the regional contractile state and loading conditions of the "normal" myocardium, which are altered in response to the distal ischemia.

Animals↗

Enhanced left ventricular endocardial border delineation with an intravenous injection of SonoVue, a new echocardiographic contrast agent: A European multicenter study.

The safety and efficacy of SonoVue (also referred to as BR1), a new contrast agent for delineating endocardial border of the left ventricle after intravenous administration, was assessed. Two hundred and eighteen patients with suspected coronary artery disease undergoing fundamental echocardiography for the assessment of left ventricle were enrolled in a prospective multicenter, single blind, cross-over study with random sequence allocation of four different doses of SonoVue. Endocardial border definition in the apical and parasternal views was scored as 0 = not visible, 1 = barely visible, and 2 = well visualized before and after contrast enhancement. Analysis was performed by two pairs of off-site observers. Safety of SonoVue was also assessed. Results of our study indicated that the mean improvements in the endocardial border visualization score were as follows: 3.1 +/- 7.8 (95% CI, 2.5 and 3.7) for 0.5 ml, 3.4 +/- 8.0 (95% CI, 2.8 and 4.0) for 1 ml, 3.4 +/- 7.9 (95% CI, 2.8 and 4.0) for 2 ml, and 3.7 +/- 8.0 (95% CI, 3.1 and 4.3) for 4 ml (P < 0.05 for all doses from baseline). Changes from baseline in endocardial visualization scores were also seen in the apical views (P < 0.05) and they were dose-dependent (P < 0.001). Similar enhancements of endocardial visualization scores were observed in the apical views in patients with suboptimal baseline echocardiographic images. Diagnostic confidence for assigning a score and image quality also were significantly better following contrast enhancement. No significant changes in the laboratory parameters and vital signs were noted following contrast enhancement, and the side effects were minimal. It was concluded that SonoVue is safe and effective in delineating endocardial border, including in patients with suboptimal baseline images.

Aged↗

Acute posterior cerebral circulation syndrome accompanied by serious cardiac rhythm disturbances: a rare but reversible complication following bypass graft angiography.

Cerebral events are recognized, although infrequent, complications of cardiac catheterization. We report on an exceptional case of a posterior cerebral circulation syndrome comprising a confusional state, amnestic disturbances, aphasia, and cortical blindness, accompanied by life-threatening cardiac arrhythmia after left and right internal mammary artery graft angiography, with complete recovery over 5 days. The diagnostic potential of computed tomography, magnetic resonance, and SPECT imaging of the brain in diagnosing this rare but important complication is illustrated. The need for early continuous monitoring of patients with clinically important cerebrovascular events postangiography is emphasized. Cathet. Cardiovasc. Intervent. 48:397-401, 1999.

Acute Disease↗

Robustness of integrated backscatter for myocardial tissue characterization.

Integrated backscatter (IB) has been used for ultrasonic tissue characterization. To assess the potential variables in IB measurements, we performed both theoretical simulations and in vitro phantom measurements. First, we simulated data in which the scatterer position randomly was varied. IB values for the resulting images were calculated. Second, RF data from a tissue-mimicking phantom were acquired. Third, an adapted imaging approach, based on phase insensitivity, was evaluated. For both the simulations and phantom measurements, IB showed a standard deviation of +/-20%. These large deviations can be explained by variations in interference of signals and are not related to the state of the tissue. Small deviations in position of the scatterers resulted in important variations in IB. They must be taken into account and may limit the use of IB in cardiological applications. An improvement potentially can be obtained using phase insensitivity in new ultrasound processing schemes.

Computer Simulation↗

Importance of flow/metabolism studies in predicting late recovery of function following reperfusion in patients with acute myocardial infarction.

AIMS: Positron emission tomographic imaging is known to be a reliable indicator of viable myocardium in chronic heart disease. Its value in acute myocardial infarction has not been studied extensively. METHODS AND RESULTS: Sixty-two patients receiving thrombolytic therapy were studied. Myocardial tissue flow and metabolism were measured at 5 days and 3 months. Recovery of left ventricular function was investigated with echocardiography or radionuclide ventriculography. In eight patients, normal flow was found in the infarct area at 5 days with no significant changes in flow, metabolism or function over the next 3 months. In 54 patients, impaired regional myocardial blood flow in the infarct zone was observed at 5 days. In 39 patients, there was a matching positron emission tomographic pattern, while in 15 the pattern was mismatched. None of the patients with a TIMI flow grade < 3 revealed recovery of left ventricular function. In seven out of 11 patients with TIMI 3 flow and a mismatching pattern, additional angioplasty was performed with functional improvement in six. CONCLUSIONS: Recovery of ventricular function is exclusively found in patients with a TIMI flow grade 3. Patients with a positron emission tomographic mismatching pattern reveal functional recovery only after subsequent angioplasty.

Aged↗

Postoperative hemodynamics of two bileaflet heart valves in the aortic position.

BACKGROUND AND AIMS OF THE STUDY: In vivo hemodynamic assessment of bileaflet aortic valve prostheses using standardized echocardiography is still uncommon; hence, adequate comparison of valve types can rarely be made. We compared the postoperative hemodynamics of St. Jude Standard valves (SJS) with those of Sorin Bicarbon valves (BC) implanted in the aortic position, using pulsed, continuous and color Doppler echocardiography. METHODS: The examination was performed four months after aortic valve prosthesis implantation in 76 patients (39 SJS valves, 37 BC valves). Valve sizes varied from 19 mm to 25 mm. Maximal and mean instantaneous pressure gradients were measured by Doppler echocardiography. Effective valve orifice area (EOA) was calculated and prosthetic valve regurgitation was assessed by color Doppler flow imaging. RESULTS: At valve sizes of 21 mm, 23 mm and 25 mm, SJS valves had a significantly lower EOAs than BC valves (p < 0.05). However, for a given nominal size, BC valves are larger, i.e. they have a larger anatomic (AOA) and geometric orifice area (GOA) than SJS valves. Consequently, BC valves were implanted in patients with a larger left ventricular outflow tract (p < 0.05). When EOA is related to the corresponding AOA, BC valves still show a larger EOA than SJS valves (p < 0.05). Prosthetic valve regurgitation is low in both valve types. CONCLUSIONS: (a) Nominal valve size is not always a good basis for comparison of hemodynamic profiles between valve types. (b) Using the relationship between EOA and AOA, the hemodynamic profile of BC valves in the aortic position is shown to be superior to that of SJS valves.

Aged↗

Can dobutamine echocardiography distinguish necrotic from ischemic myocardium, early after myocardial infarction?

UNLABELLED: The aim of this study was to evaluate the usefulness of dobutamine echocardiography (DE) in distinguishing necrotic from ischemic myocardium in infarct zones. We performed DE in 39 patients, 3 to 5 days after admission for a first, acute myocardial infarction, treated with thrombolysis. DE was considered positive if wall motion in the infarct zone worsened progressively during increasing dose of dobutamine or if wall motion in the infarct zone initially improved at low dose of dobutamine and deteriorated at higher dose. The results of DE were correlated to the evolution of wall motion in the infarct zone after 3 months and to the need for supplementary balloon dilatation. In 15 of the 39 patients, there was evidence of residual ischemia in the infarct zone. Twenty of the 39 patients had a positive dobutamine echocardiogram. Eleven of these 20 patients had evidence of residual ischemia in the infarct zone. They showed generalized changes of wall motion in the total infarct territory during DE. The other 9 patients demonstrated only localized changes of wall motion in isolated segments of the infarct zone during DE. None of these patients had evidence of residual ischemia. IN CONCLUSION: DE seems worthwhile in the detection of residual ischemia in the region of infarction. To reduce the number of false positive DE early after myocardial infarction, only extensive changes of wall motion in the total infarct territory should be accepted as indicative of residual ischemia in the infarct zone.

Dobutamine↗

Left ventricular quantification with breath-hold MR imaging: comparison with echocardiography.

To evaluate the reproducibility of measurements of left ventricular (LV) dimensions, function, and myocardial mass, segmented k-space gradient-recalled-echo (GRE) magnetic resonance (MR) imaging was performed on two occasions on 12 healthy volunteers. To compare the MR data, all volunteers underwent a two-dimensional echocardiography with determination of LV dimensions and function. The left ventricle was imaged during breath-hold by consecutive, contiguous short-axis views at end-diastole and end-systole. An average of eight short-axis views was needed to encompass the whole left ventricle. This fast MR sequence limited the total acquisition time to 12 min. LV volumes and masses were calculated after manual delineation of epicardial and endocardial surfaces by two observers in a blinded fashion. Interstudy variability varied between 4.1% and 10.3% for LV end-diastolic volume and end-systolic volume, respectively. Differences in interobserver variability were smaller and varied between 3.6% and 7.3% for LV ejection fraction and end-diastolic volume, respectively. Intraobserver variabilities ranged between 2.0% and 7.0% for LV ejection fraction and end-systolic volume, respectively. These variability percentages agree very well with other studies in literature using other MR sequences. No significant differences in LV dimensions or function were found between MR imaging and echocardiography. In conclusion, this MR sequence allows fast and reproducible LV quantification.

Adult↗

Intravascular ultrasound versus angiography for measurement of luminal diameters in normal and diseased coronary arteries.

Quantitation of coronary luminal diameter with a 20 MHz mechanically rotating intravascular ultrasound (IVUS) catheter was compared with orthogonal-view cineangiography by use of a semiautomated edge-detection algorithm in 48 patients undergoing coronary angioplasty. Quantitative comparison of 196 matched segments was attempted, but in only 174 (88.8%) was a direct comparison of the two techniques possible. In angiographically normal coronary arteries (46 segments) the correlation between the values obtained by quantitative coronary angiography (QCA) and those achieved by IVUS was excellent (r = 0.92, p < 0.0001). For mild stenoses (80 segments) the correlation coefficient was only fair (r = 0.467, p < 0.001). After percutaneous transluminal coronary angioplasty the correlation coefficient between IVUS and QCA data (48 segments) was very weak (r = 0.282, p < 0.05). In conclusion, coronary IVUS is feasible and safe and even for a limited range of coronary arterial narrowing, significant correlations between IVUS and QCA measurements of minimal lumen diameter were found. They were excellent in normal coronary arteries, moderate in mildly diseased arteries, and weak after balloon angioplasty.

Angioplasty, Balloon, Coronary↗

Acquisition and processing of the radio-frequency signal in echocardiography: a new global approach.

Recently there has been an increasing interest in the use of the "raw" radio-frequency (RF) signal generated in echocardiography for use in tissue-characterization to distinguish between normal and pathological myocardium, for automatic delineation of the endocardial border without being limited by the weak contrast of the traditional video images, and for use in contrast echography, where it could offer the possibility to visualize perfusion using intravenous contrast injections. One of the main problems in this kind of research is the acquisition of the signal having a high frequency and large bandwidth. We have developed a new global method for the acquisition of this RF signal. To digitize the data, a video sequencer is used. In this way it becomes possible to sample all available data generated by the echographic equipment during at least 1 s. This means that all data of the complete sector scan during a complete heart-cycle can be digitized without using any data reduction technique or triggering on the electrocardiogram. The advantage of this approach is that all characteristics of the signal can be studied, without being limited by data reduction techniques used during acquisition. This method enables us to calculate parameters such as "integrated backscatter," or to investigate the signal more extensively, e.g., by using spectrum analysis. We can compare different regions of the myocardium and examine them during the heart-cycle, all within the same beat. We have also written a software package for the processing of the large amount of data resulting from the acquisition.

Animals↗

Determination of left ventricular volume by two-dimensional echocardiography: comparison with magnetic resonance imaging.

Left ventricular volume was determined in 12 healthy volunteers using a newly developed two-dimensional echocardiographic delineation method. The results were compared with those of magnetic resonance imaging, which served as the method of reference. Left ventricular end-diastolic volume was 123 +/- 12 ml, echocardiographically defined, and 121 +/- 12 ml calculated with magnetic resonance imaging. End-systolic volume was 41 +/- 7 ml on echocardiography and 37 +/- 6 ml on magnetic resonance imaging. Left ventricular ejection fraction was 67 +/- 4%, echocardiographically defined, and 70 +/- 5%, calculated with magnetic resonance imaging. There was no statistical difference for any of the measured parameters. Interstudy and inter-observer variability was minimal. In conclusion, in healthy volunteers left ventricular volume was accurately defined, using this newly developed two-dimensional echocardiographic delineation method. During endocardial delineation a dynamic display is continuously available on a second window, allowing precise visual edge-detection. Moreover, corrections can be made easily and quickly. These two advantages enhance the accuracy of the method, even in cases of poor echogenicity.

Adult↗

Platypnoea syndrome caused by atrial septal aneurysm.

A patient with platypnoea after right pneumonectomy and radiotherapy is described. On transoesophageal contrast echocardiography and cardiac catheterization, an atrial septal aneurysm with interatrial right-to-left shunting was detected. Symptoms disappeared after surgical correction. To the best of our knowledge, this is the first report of a patient with a septal aneurysm and severe platypnoea.

Aged↗

Role of intravascular ultrasound in coronary artery disease: a new gold standard? An overview.

Although selective contrast coronary arteriography has been the gold standard approach for coronary imaging since more than 30 years, new coronary imaging techniques are currently under development. Intravascular ultrasound (IVUS) is perhaps the most promising of these additional techniques. IVUS makes use of miniaturised crystals incorporated at catheter tips and provides real time, cross-sectional and longitudinal, high resolution images of the arterial wall with three-dimensional reconstruction capabilities (Pandian, 1989; Coy et al., 1991; Liebsen & Klein, 1992). Different devices have been constructed. Actually two types are being used: mechanical (hand-rotated or motor-driven) systems and phased array systems using high-frequency (20-30 MHz) transducers (Bom et al., 1989). Coronary ultrasound imaging performed during catheterization is feasible and safe as demonstrated in several studies examining normal and pathologic coronary arteries (De Scheerder et al., in press).

Coronary Disease↗