M C Kolios

Publications and source records attributed to M C Kolios.

14 recordsLinked to original sources

Monitoring structural changes in cells with high-frequency ultrasound signal statistics.

We investigate the use of signal envelope statistics to monitor and quantify structural changes during cell death using an in vitro cell model. Using a f/2.35 transducer (center frequency 20 MHz), ultrasound backscatter data were obtained from pellets of acute myeloid leukemia cells treated with a DNA-intercolating chemotherapy drug, as well as from pellets formed with mixtures of treated and untreated cells. Simulations of signals from pellets of mixtures of cells were generated as a summation of point scatterers. The signal envelope statistics were examined by fitting the Rayleigh and generalized gamma distributions. The fit parameters of the generalized gamma distribution showed sensitivity to structural changes in the cells. The scale parameter showed a 200% increase (p<0.05) between untreated and cells treated for 24 h. The shape parameter showed a 50% increase (p<0.05) over 24 h. Experimental results showed reasonable agreement with simulations. The results indicate that high-frequency ultrasound signal statistics can be used to monitor structural changes within a very low percentage of treated cells in a population, raising the possibility of using this technique in vivo.

Antineoplastic Agents↗

High-frequency ultrasound scattering from microspheres and single cells.

Assessing the proportion of biological cells in a volume of interest undergoing structural changes, such as cell death, using high-frequency ultrasound (20-100 MHz), requires the development of a theoretical model of scattering by any arbitrary cell ensemble. A prerequisite to building such a model is to know the scattering by a single cell in different states. In this paper, a simple model for the high-frequency acoustic scattering by one cell is proposed. A method for deducing the backscatter transfer function from a single, subresolution scatterer is also devised. Using this method, experimental measurements of backscatter from homogeneous, subresolution polystyrene microspheres and single, viable eukaryotic cells, acquired across a broad, continuous range of frequencies were compared with elastic scattering theory and the proposed cell scattering model, respectively. The resonant features observed in the backscatter transfer function of microspheres were found to correspond accurately to theoretical predictions. Using the spacing of the major spectral peaks in the transfer functions obtained experimentally, it is possible to predict microsphere diameters with less than 4% error. Such good agreement was not seen between the cell model and the measured backscatter from cells. Possible reasons for this discrepancy are discussed.

Apoptosis↗

Ultrasonic spectral parameter characterization of apoptosis.

Ultrasound (US) spectral analysis methods are used to analyze the radiofrequency (RF) data collected from cell pellets exposed to chemotherapeutics that induce apoptosis and other chemicals that induce nuclear transformations. Calibrated backscatter spectra from regions-of-interest (ROI) were analyzed using linear regression techniques to calculate the spectral slope and midband fit. Two f/2 transducers, with operating frequencies of 30 and 34 MHz (relative bandwidths of 93% and 78%, respectively) were used with a custom-made imaging system that enabled the collection of the raw RF data. For apoptotic cells, the spectral slope increased from 0.37 dB/MHz before drug exposure to 0.57 dB/MHz 24 h after, corresponding to a change in effective scatterer radius from 8.7 to 3.2 microm. The midband fit increased in a time-dependent fashion, peaking at 13dB 24 h after exposure. The statistical deviation of the spectral parameters was in close agreement with theoretical predictions. The results provide a framework for using spectral parameter methods to monitor apoptosis in in vitro and in in vivo systems and are being used to guide the design of system and signal analysis parameters.

Apoptosis↗

Comparison of thermal damage calculated using magnetic resonance thermometry, with magnetic resonance imaging post-treatment and histology, after interstitial microwave thermal therapy of rabbit brain.

Clinical application of high-temperature thermal therapy as a treatment for solid tumours requires an accurate and close to real-time method for assessing tissue damage. Imaging methods that detect structural changes during heating may underestimate the extent of thermal damage. This is due to the occurrence of delayed damage manifested at tissue locations exposed to temperatures lower than those required to cause immediate structural changes. An alternative approach is to measure temperature and then calculate the expected damage based on the temperature history at each tissue location. Magnetic resonance (MR) imaging methods now allow temperature maps of the target and surrounding tissues to be generated in almost real-time. The aim of this work was to evaluate whether thermal damage zones calculated on the basis of MR thermometry maps measured during heating correspond to actual tissue damage as measured after treatment by histological methods and MR imaging. Four male rabbits were treated with high-temperature thermal therapy delivered in the brain by a single microwave antenna operating at 915 MHz. MR scanning was performed before, during and after treatment in a 1.5 T whole-body scanner. Temperature maps were produced using the proton resonance frequency (PRF) shift method of MR thermometry. In addition, conventional T1-weighted and T2-weighted spin-echo images were acquired after treatment. Thermal damage zones corresponding to cell death, microvascular blood flow stasis and protein coagulation were calculated using an Arrhenius analysis of the MR temperature/time course data. The calculated zones were compared with the lesions seen on histopathological examination of the brains which were removed within 6-8 h of treatment. The results showed that calculated damage zones based on MR thermometry agreed well with areas of damage as assessed using histology after heating was completed. The data suggest that real-time calculations of final expected thermal damage based on an Arrhenius analysis of MR temperature data may provide a useful method of real-time monitoring of thermal therapy when combined with conventional T2-weighted images taken after treatment.

Animals↗

The effects of dynamic optical properties during interstitial laser photocoagulation.

A nonlinear mathematical model was developed and experimentally validated to investigate the effects of changes in optical properties during interstitial laser photocoagulation (ILP). The effects of dynamic optical properties were calculated using the Arrhenius damage model, resulting in a nonlinear optothermal response. This response was experimentally validated by measuring the temperature rise in albumen and polyacrylamide phantoms. A theoretical study of ILP in liver was conducted constraining the peak temperatures below the vaporization threshold. The temperature predictions varied considerably between the static and dynamic scenarios, and were confirmed experimentally in phantoms. This suggests that the Arrhenius model can be used to predict dynamic changes in optical and thermal fields. An increase in temperature rise due to a decrease in light penetration within the coagulated region during ILP of the liver was also demonstrated. The kinetics of ILP are complex and nonlinear due to coagulation, which changes the tissue properties during treatment. These complex effects can be adequately modelled using an Arrhenius damage formulation.

Acrylic Resins↗

Ultrasound imaging of apoptosis: high-resolution non-invasive monitoring of programmed cell death in vitro, in situ and in vivo.

A new non-invasive method for monitoring apoptosis has been developed using high frequency (40 MHz) ultrasound imaging. Conventional ultrasound backscatter imaging techniques were used to observe apoptosis occurring in response to anticancer agents in cells in vitro, in tissues ex vivo and in live animals. The mechanism behind this ultrasonic detection was identified experimentally to be the subcellular nuclear changes, condensation followed by fragmentation, that cells undergo during apoptosis. These changes dramatically increase the high frequency ultrasound scattering efficiency of apoptotic cells over normal cells (25- to 50-fold change in intensity). The result is that areas of tissue undergoing apoptosis become much brighter in comparison to surrounding viable tissues. The results provide a framework for the possibility of using high frequency ultrasound imaging in the future to non-invasively monitor the effects of chemotherapeutic agents and other anticancer treatments in experimental animal systems and in patients.

Animals↗

An investigation of the flow dependence of temperature gradients near large vessels during steady state and transient tissue heating.

Temperature distributions measured during thermal therapy are a major prognostic factor of the efficacy and success of the procedure. Thermal models are used to predict the temperature elevation of tissues during heating. Theoretical work has shown that blood flow through large blood vessels plays an important role in determining temperature profiles of heated tissues. In this paper, an experimental investigation of the effects of large vessels on the temperature distribution of heated tissue is performed. The blood flow dependence of steady state and transient temperature profiles created by a cylindrical conductive heat source and an ultrasound transducer were examined using a fixed porcine kidney as a flow model. In the transient experiments, a 20 s pulse of hot water, 30 degrees C above ambient, heated the tissues. Temperatures were measured at selected locations in steps of 0.1 mm. It was observed that vessels could either heat or cool tissues depending on the orientation of the vascular geometry with respect to the heat source and that these effects are a function of flow rate through the vessels. Temperature gradients of 6 degrees C mm(-1) close to large vessels were routinely measured. Furthermore, it was observed that the temperature gradients caused by large vessels depended on whether the heating source was highly localized (i.e. a hot needle) or more distributed (i.e. external ultrasound). The gradients measured near large vessels during localized heating were between two and three times greater than the gradients measured during ultrasound heating at the same location, for comparable flows. Moreover, these gradients were more sensitive to flow variations for the localized needle heating. X-ray computed tomography data of the kidney vasculature were in good spatial agreement with the locations of all of the temperature variations measured. The three dimensional vessel path observed could account for the complex features of the temperature profiles. The flow dependences of the transient temperature profiles near large vessels during the pulsed experiments were consistent with the temperature distributions measured in the steady state experiments and provided unique insights into the process of convective heat transfer in tissues. Finally, it was shown that even for very short treatment times (3-20 s), large vessels had significant effects on the tissue temperature distributions.

Angiography↗

Experimental evaluation of two simple thermal models using transient temperature analysis.

Thermal models are used to predict temperature distributions of heated tissues during thermal therapies. Recent interest in short duration high temperature therapeutic procedures necessitates the accurate modelling of transient temperature profiles in heated tissues. Blood flow plays an important role in tissue heat transfer and the resultant temperature distribution. This work examines the transient predictions of two simple mathematical models of heat transfer by blood flow (the bioheat transfer equation model and the effective thermal conductivity equation model) and compares their predictions to measured transient temperature data. Large differences between the two models are predicted in the tissue temperature distribution as a function of blood flow for a short heat pulse. In the experiments a hot water needle, approximately 30 degrees C above ambient, delivered a 20 s heating pulse to an excised fixed porcine kidney that was used as a flow model. Temperature profiles of a thermocouple that primarily traversed the kidney cortex were examined. Kidney locations with large vessels were avoided in the temperature profile analysis by examination of the vessel geometry using high resolution computed tomography angiography and the detection of the characteristic large vessel localized cooling or heating patterns in steady-state temperature profiles. It was found that for regions without large vessels, predictions of the Pennes bioheat transfer equation were in much better agreement with the experimental data when compared to predictions of the scalar effective thermal conductivity equation model. For example, at a location r approximately 2 mm away from the source, the measured delay time was 10.6 +/- 0.5 s compared to predictions of 9.4 s and 5.4 s of the BHTE and ETCE models, respectively. However, for the majority of measured locations, localized cooling and heating effects were detected close to large vessels when the kidney was perfused. Finally, it is shown that increasing flow in regions without large vessels minimally perturbs temperature profiles for short exposure times; regions with large vessels still have a significant effect.

Angiography↗

A theoretical comparison of energy sources--microwave, ultrasound and laser--for interstitial thermal therapy.

A number of heating sources are available for minimally invasive thermal therapy of tumours. The purpose of this work was to compare, theoretically, the heating characteristics of interstitial microwave, laser and ultrasound sources in three tissue sites: breast, brain and liver. Using a numerical method, the heating patterns, temperature profiles and expected volumes of thermal damage were calculated during standard treatment times with the condition that tissue temperatures were not permitted to rise above 100 degrees C (to ensure tissue vaporization did not occur). Ideal spherical and cylindrical applicators (200 microm and 800 microm radii respectively) were modelled for each energy source to demonstrate the relative importance of geometry and energy attenuation in determining heating and thermal damage profiles. The theoretical model included the effects of the collapse of perfusion due to heating. Heating patterns were less dependent on the energy source when small spherical applicators were modelled than for larger cylindrical applicators due to the very rapid geometrical decrease in energy with distance for the spherical applicators. For larger cylindrical applicators, the energy source was of greater importance. In this case, the energy source with the lowest attenuation coefficient was predicted to produce the largest volume of thermally coagulated tissue, in each tissue site.

Brain↗

Ultrasonic biomicroscopy of viable, dead and apoptotic cells.

Ultrasonic imaging is frequently used in medical diagnosis to differentiate normal and tumour tissues. Here we investigate if distinct types of cell death can be discriminated through the use of ultrasound biomicroscopy. By using a well-controlled system in vitro, we demonstrate that this imaging modality can be used to differentiate living cells, dead cells and cells that have died by programmed cell death or apoptosis. The results indicate a greater than twofold ultrasound backscatter signal from apoptotic cells in comparison to viable cells, whereas heat-killed cells exhibit an intermediate level of ultrasound backscatter. The results have potential implications in the study of disease-related biological processes involving apoptosis.

Antineoplastic Agents↗

Magnetic resonance imaging of temperature changes during interstitial microwave heating: a phantom study.

Changes in magnetic resonance (MR) signals during interstitial microwave heating are reported, and correlated with simultaneously acquired temperature readings from three fiber-optic probes implanted in a polyacrylamide gel phantom. The heating by a MR-compatible microwave antenna did not interfere with simultaneous MR image data acquisition. MR phase-difference images were obtained using a fast two-dimensional-gradient echo sequence. From these images the temperature-sensitive resonant frequency of the 1H nuclei was found to decrease approximately by 0.008 ppm/ degree C. The method and results presented here demonstrate that noninvasive MR-temperature imaging can be performed simultaneously with interstitial microwave thermal treatment.

Biophysical Phenomena↗

Blood flow cooling and ultrasonic lesion formation.

This article examines lesion formation using focused ultrasound and demonstrates how blood flow may affect lesion dimensions using a theoretical model. The effects of blood flow on temperature distributions during ultrasonic lesioning are examined for both regional cooling by the microvasculature and localized cooling due to thermally significant vessels. Regional cooling was critically assessed using two models: the Pennes bioheat transfer equation and the scalar effective thermal conductivity equation. Localized cooling was modeled by adding an advective term in the heat diffusion equation in regions enclosed by thermally significant vessels. A finite difference approach was used to solve the basic equations of heat transfer in perfused tissues in cylindrical coordinates. The extent of the lesioned tissue was determined by the accumulated thermal dose at each location. The size of the lesion was then calculated from the boundaries of the thermal isodose curves generated by the simulations. The results were compared to published in vivo lesion data in rat liver. It was shown that even for short ultrasound exposure times (approximately 8 s), blood flow may play an important role in the thermal dose distribution.

Algorithms↗

Large blood vessel cooling in heated tissues: a numerical study.

Large blood vessels can produce steep temperature gradients in heated tissues leading to inadequate tissue temperatures during hyperthermia. This paper utilizes a finite difference scheme to solve the basic equations of heat transfer and fluid flow to model blood vessel cooling. Unlike previous formulations, heat transfer coefficients were not used to calculate heat transfer to large blood vessels. Instead, the conservation form of the finite difference equations implicitly modelled this process. Temperature profiles of heated tissues near thermally significant vessels were calculated. Microvascular heat transfer was modelled either as an effective conductivity or a heat sink. An increase in perfusion in both microvascular models results in a reduction of the cooling effects of large vessels. For equivalent perfusion values, the effective conductivity model predicted more effective heating of the blood and adjacent tissue. Furthermore, it was found that optimal vessel heating strategies depend on the microvascular heat transfer model adopted; localized deposition of heat near vessels could produce higher temperature profiles when microvascular heat transfer was modelled according to the bioheat transfer equation (BHTE) but not the effective thermal conductivity equation (ETCE). Reduction of the blood flow through thermally significant vessels was found to be the most effective way of reducing localized cooling.

Animals↗

Influence of transition rates and scan rate on kinetic simulations of differential scanning calorimetry profiles of reversible and irreversible protein denaturation.

The thermodynamic parameters characterizing protein folding can be obtained directly using differential scanning calorimetry (DSC). They are meaningful only for reversible unfolding at equilibrium, which holds for small globular proteins; however, the unfolding or denaturation of most large, multidomain or multisubunit proteins is either partially or totally irreversible. The simplest kinetic model describing partially irreversible denaturation requires three states: Formula [see text] We obtain numerical solutions for N, U, and D as a function of temperature for this model and derive profiles of excess specific heat (Cp) in terms of the reduced variables v/ki and k1/k3, where v is the scan rate. The three-state model reduces to the two-state reversible or irreversible models for very large or very small values of k1/k3, respectively. The apparent transition temperature (Tapp) is always reduced by the irreversible step (U-->D). For all values of k3, Tapp is independent of v/k1 at sufficiently slow scan rates, even when denaturation is highly irreversible, but increases identically for all models at fast scan rates in which case the excess specific heat profile is determined by the rate of unfolding. Accurate values of delta H and delta S can be obtained for the reversible step only when k1 is more than 2000-50,000 times greater than k3. In principle, approximate values for the ratio k1/k3 can be obtained from plots of fraction unfolded vs fraction irreversibly denatured as a function of temperature; however, the fraction irreversibly denatured is difficult to measure accurately by DSC alone.(ABSTRACT TRUNCATED AT 250 WORDS)

Calorimetry, Differential Scanning↗