PubMed Health⌕ Search

Biomedical subjects

M C Marconi

Publications and source records attributed to M C Marconi.

13 recordsLinked to original sources

Continuous high-repetition-rate operation of collisional soft-x-ray lasers with solid targets.

We have generated a laser average output power of 2 microW at a wavelength of 13.9 nm by operating a tabletop laser-pumped Ni-like Ag laser at a 5 Hz repetition rate, using a solid helicoidal target that is continuously rotated and advanced to renew the target surface between shots. More than 2 x 10(4) soft-x-ray laser shots were obtained by using a single target. Similar results were obtained at 13.2 nm in Ni-like Cd with a Cd-coated target. This scheme will allow uninterrupted operation of laser-pumped tabletop collisional soft-x-ray lasers at a repetition rate of 10 Hz for a period of hours, enabling the generation of continuous high average soft-x-ray powers for applications.

Journal Article↗

Sub-38 nm resolution tabletop microscopy with 13 nm wavelength laser light.

We have acquired images with a spatial resolution better than 38 nm by using a tabletop microscope that combines 13 nm wavelength light from a high-brightness tabletop laser and Fresnel zone plate optics. These results open a gateway to the development of compact and widely available extreme-ultraviolet imaging tools capable of inspecting samples in a variety of environments with a 15-20 nm spatial resolution and a picosecond time resolution.

Journal Article↗

Plasma conditions for improved energy coupling into the gain region of the Ni-like Pd transient collisional x-ray laser.

We have directly probed the conditions in which the Ni-like Pd transient collisional x-ray laser is generated and propagates by measuring the near-field image and by utilizing picosecond resolution soft x-ray laser interferometry of the preformed Pd plasma gain medium. The electron density and gain region of the plasma have been determined experimentally and are found to be in good agreement with simulations. We observe a strong dependence of the laser pump-gain medium coupling on the laser pump parameters. The most efficient coupling occurs with the formation of lower density gradients in the preformed plasma and when the duration of the main heating pulse is comparable to the gain lifetime (approximately 10 ps for mid- Z Ni-like schemes). This increases the output intensity by more than an order of magnitude relative to the commonly utilized case where the same pumping energy is delivered within a shorter heating pulse duration (<3 ps) . In contrast, the higher intensity heating pulses are observed to be absorbed at higher electron densities and in regions where steep density gradients limit the effective length of the gain medium.

Journal Article↗

Nanoimaging with a compact extreme-ultraviolet laser.

Images with a spatial resolution of 120-150 nm were obtained with 46.9 nm light from a compact capillary-discharge laser by use of the combination of a Sc-Si multilayer-coated Schwarzschild condenser and a free-standing imaging zone plate. The results are relevant to the development of compact extreme-ultraviolet laser-based imaging tools for nanoscience and nanotechnology.

Equipment Design↗

Observation of a multiply ionized plasma with index of refraction greater than one.

We present clear experimental evidence showing that the contribution of bound electrons can dominate the index of refraction of laser-created plasmas at soft x-ray wavelengths. We report anomalous fringe shifts in soft x-ray laser interferograms of Al laser-created plasmas. The comparison of measured and simulated interferograms shows that this results from the dominant contribution of low charge ions to the index of refraction. This usually neglected bound electron contribution can affect the propagation of soft x-ray radiation in plasmas and the interferometric diagnostics of plasmas for many elements.

Journal Article↗

Saturated high-repetition-rate 18.9-nm tabletop laser in nickellike molybdenum.

We report saturated operation of an 18.9-nm laser at 5-Hz repetition rate. An amplification with a gain-length product GL of 15.5 is obtained in the 4d 1S0-4p 1P1 laser line of Ni-like Mo in plasmas heated at grazing incidence with approximately 1-J pulses of 8.1-ps duration from a tabletop laser system. Lasing is obtained over a broad range of time delays and pumping conditions. We also measure a GL of 13.5 in the 22.6-nm transition of the same ion. The results are of interest for numerous applications requiring high-repetition-rate lasers at wavelengths below 20 nm.

Journal Article↗

Guiding of intense laser beams in highly ionized plasma columns generated by a fast capillary discharge.

We have demonstrated the guiding of laser pulses with peak intensities up to 2.2 x 10(17) W/cm(2) in a 5.5 cm long plasma column containing highly charged Ar ions generated by a fast capillary discharge. A rapid discharge-driven hydrodynamic compression guides progressively lower order modes through a plasma with increasing density and degree of ionization, until the guide collapses on axis. The lowest order mode (FWHM approximately 50 microm) is guided with 75% transmission efficiency shortly before the plasma reaches the conditions for lasing in Ne-like Ar. The subsequent rapid plasma expansion forms a significantly leakier and more absorbent guide.

Journal Article↗

Two-dimensional effects in laser-created plasmas measured with soft-x-ray laser interferometry.

Soft-x-ray laser interferograms of laser-created plasmas generated at moderate irradiation intensities (1 x 10(11)-7 x 10(12) W cm(-2)) with lambda=1.06 microm light pulses of approximately 13-ns-FWHM (full width at half maximum) duration and narrow focus (approximately 30 microm) reveal the unexpected formation of an inverted density profile with a density minimum on axis and distinct plasma sidelobes. Model simulations show that this strong two-dimensional hydrodynamic behavior is essentially a universal phenomena that is the result of plasma radiation induced mass ablation and cooling in the areas surrounding the focal spot.

Journal Article↗

Picosecond x-ray laser interferometry of dense plasmas.

We present the first results from picosecond interferometry of dense laser-produced plasmas using a soft x-ray laser. The picosecond duration and short wavelength of the 14.7 nm Ni-like Pd laser mitigates effects associated with motion blurring and refraction through millimeter-scale plasmas. This enables direct measurement of the electron-density profile to within 10 microm of the target surface. A series of high-quality two-dimensional (2D) density measurements provide unambiguous characterization of the time evolution in a fast-evolving plasma suitable for validation of existing 1D and 2D hydrodynamic codes.

Journal Article↗

Soft-x-ray laser interferometry of a pinch discharge using a tabletop laser.

We have used a tabletop soft-x-ray laser and a wave-front division interferometer to probe the plasma of a pinch discharge. A very compact capillary discharge-pumped Ne-like Ar laser emitting at 46.9 nm was combined with a wave division interferometer based on Lloyd's mirror and Sc-Si multilayer-coated optics to map the electron density in the cathode region of the discharge. This demonstration of the use of tabletop soft-x-ray laser in plasma interferometry could lead to the widespread use of these lasers in the diagnostics of dense plasmas.

Journal Article↗

Micronucleus induction by low doses of X-rays in Vicia faba root tips.

Studies on the micronucleus test in Vicia faba root tips (VM test) were carried out in order to estimate the effects at low doses of X-rays (1, 2, 4, 8 and 12 R). The control value of micronucleus frequency is about 0.44/1000 cells. The dose where the micronucleus frequency is twice that of the control was estimated at 1.384 R. There was a linear kinetic dose response for the low-dose range studied here.

Cell Nucleus↗

[The serum fructosamine test in the control plan of glucose homeostasis].

A new method to measure serum glycosylated proteins as index of diabetic control is evaluated. Precision, recovery and interference tests have been evaluated. A good correlation of fructosamine values with glycosylated haemoglobin and glucose in normal and diabetic patients was found. The analytical performance and its simple application to automated instruments make this test suitable for monitoring diabetes mellitus and for assessing intermediate-term control of blood glucose.

Blood Proteins↗

[Application to an automatic system of a direct method for determining atypical variants of cholinesterase using succinyldithiocholine as substrate].

The determination of human serum cholinesterase (EC 3.1.1.8) is frequently requested to detect patients with atypical forms of the enzyme which reacts abnormally with succinylcholine (suxamethonium), employed as a neuromuscular blocking agent. Usually, for biochemical identification of succinylcholine sensitive individuals the standard reaction is run with and without the inhibitors, notably dibucaine. A new test for direct determination of succinylcholine sensitive individuals which use a substrate analogue of succinylcholine was applied to a automated instrument. The linearity, precision, recovery, interference and correlation of the method have been evaluated. We have estimated the reference intervals for a population of 364 healthy subjects subdivided for sex, three atypical homozygotes and two atypical heterozygotes. On the basis of analytical performance we can conclude that this test may offer a further parameter for preoperative screening of individuals with an abnormal response to the muscle relaxant succinylcholine, thus avoiding the determination of genotype by measurement of dibucaine number.

Bilirubin↗