PubMed Health⌕ Search

Biomedical subjects

M C Miller

Publications and source records attributed to M C Miller.

At least 19 recordsLinked to original sources

Evidence for high-efficiency laser-heated hohlraum performance at 527 nm.

A series of experiments conducted on the HELEN laser system [M. J. Norman, Appl. Opt.4120023497], into thermal x-ray generation from hohlraum targets using 527 nm (2omega) wavelength laser light, has shown that it is possible to exceed radiation temperatures previously thought limited by high levels of superthermal or hot electron production or stimulated backscatter. This Letter questions whether the assumptions traditionally applied to hohlraum design with respect to hot plasma filling and the use of 2omega light are too conservative.

Journal Article↗

Efficient multi-keV X-ray sources from Ti-doped aerogel targets.

We have measured the production of hnu approximately 4.7 keV x rays from low-density Ti-doped aerogel (rho approximately 3 mg/cc) targets at the OMEGA laser facility (University of Rochester), with the goal of maximizing x-ray output. Forty OMEGA beams (lambda(L)=0.351 microm) illuminated the two cylindrical faces of the target with a total power that ranged from 7 to 14 TW. The laser fully ionizes the target (n(e)/n(crit)</=0.1), and a laser-bleaching wave excites, supersonically, the high-Z emitter ions in the sample. Ti K-shell x-ray emission was spectrally resolved with a two-channel crystal spectrometer and also with a set of filtered aluminum x-ray diodes; both instruments provide absolute measurement of the multi-keV x-ray emission. We find between 40 and 260 J of output with 4.67</=hnu</=5.0 keV.

Journal Article↗

Stromal-epithelial measurements of prostate cancer in native Japanese and Japanese-American men.

We measured the histologic stromal and epithelial tissue components of the benign (normal) and malignant tissue compartments of Japanese-Americans (J-A) and native Japanese (NJ) men living in Japan. The patient cohort included 25 NJ men undergoing radical prostatectomy (RP) in Nagoya, Japan and 25 J-A (second or third generation US born). We conducted tissue image quantitation (in-house image software) of the stromal and epithelial compartments in malignant and adjacent normal tissue areas from a tissue microarray (TMA) selected from radical prostatectomy (RP) blocks. Stromal-epithelial (S-E) areas were determined using immunohistochemical stains for CAM-5.2 epithelial cytokeratin marker and the Masson trichrome stain to measure the stroma component. We observed differences in the volumes of normal and cancer epithelium and stroma within both the J-A and NJ study populations (P<0.01). Only the individual average cancer epithelium (CE) volume (JA=24.1 vs NJ=29.9) differed significantly between the NJ and J-A study populations (P=0.03). Consequently, the S-E ratio in NJ group was significantly different from that of J-A population (P=0.05). The decrease in S-E ratio noted in the malignant tissues of NJ prostate tissue may provide a biological marker for differentiation of the two groups and suggests a need for further investigations into the molecular basis for these histologic differences.

Aged↗

Stresses in polyethylene liners in a semiconstrained ankle prosthesis.

A finite element model of a semiconstrained ankle implant with the tibia and fibula was constructed so that the stresses in the polyethylene liner could be computed. Two different widths of talar components were studied and proximal boundary conditions were computed from an inverse process providing a load of five times body weight appropriately distributed across the osseous structures. von Mises stresses indicated small regions of localized yielding and contact stresses that were similar to those in acetabular cup liners. A wider talar component with 36% more surface area reduced contact stress and von Mises stresses at the center of the polyethylene component by 17%.

Aged↗

Magnetic fields produced by hand held hair dryers, stereo headsets, home sewing machines, and electric clocks.

A recent epidemiologic study reported associations between leukemia risk in children and their personal use of television (TV) sets, hair dryers, and stereo headsets, and the prenatal use by their mothers of sewing machines. To provide exposure data to aid in the interpretation of these findings, extremely and very low frequency (ELF and VLF) magnetic fields produced by a sample of each type of appliance were characterized in a field study of volunteers conducted in Washington DC and its Maryland suburbs. Questionnaire data regarding children's or mothers' patterns of usage of each type of appliance were also collected. ELF magnetic fields measured 10 cm from the nozzles of hair dryers were elevated over the ambient by a mean factor of 17 when these devices were in use. Fields near headsets being used to listen to music were not distinguishable from ambient levels except at frequencies below and well above 60 Hz and, even then, field levels were < 0.01 microT. Home sewing machines produced ELF magnetic fields that were elevated by a factor of 2.8 over ambient levels at the front surfaces of the lower abdomens of mothers. Estimated mean daily times of usage of hair dryers, stereo headsets, and sewing machines were 2.6, 19, and 17 minutes, respectively. These data and previously published data on TV sets, do not provide a consistent picture of increased (or decreased) leukemia risk in relation to increasing peak or time weighted average (TWA) ELF magnetic field exposure. The data could, however, conceivably be compatible with some more complex biophysical model with unknown properties. Overall, the results of this study provide little evidence supporting the hypothesis that peak or TWA ELF magnetic fields produced by appliances are causally related to the risk of childhood leukemia in children.

Adolescent↗

Efficient multi-keV underdense laser-produced plasma radiators.

Novel, efficient x-ray sources have been created by supersonically heating a large volume of Xe gas. A laser-induced bleaching wave quickly ionizes the high- Z gas, and the resulting plasma emits x rays. This method significantly improves the production of hard x rays because less energy is lost to kinetic energy and sub-keV x rays. The conversion efficiency of laser energy into L-shell radiation between 4-7 keV is measured at approximately 10%, an order of magnitude higher than efficiencies measured from solid disk targets. This higher flux enables material testing and backlighting in new regimes and scales well to future high-powered lasers.

Journal Article↗

Structural mechanisms of QacR induction and multidrug recognition.

The Staphylococcus aureus multidrug binding protein QacR represses transcription of the qacA multidrug transporter gene and is induced by structurally diverse cationic lipophilic drugs. Here, we report the crystal structures of six QacR-drug complexes. Compared to the DNA bound structure, drug binding elicits a coil-to-helix transition that causes induction and creates an expansive multidrug-binding pocket, containing four glutamates and multiple aromatic and polar residues. These structures indicate the presence of separate but linked drug-binding sites within a single protein. This multisite drug-binding mechanism is consonant with studies on multidrug resistance transporters.

Bacterial Proteins↗

Prediction of prostate carcinoma stage by quantitative biopsy pathology.

BACKGROUND: Considerable evidence has shown that the use of computational algorithms to combine pretreatment clinical and pathology results can enhance predictions of patient outcome. The aim of this study was to prove that the application of such methods to predict patient-specific likelihoods of organ-confined (OC) prostate carcinoma (PCA) may be helpful to patients and physicians when they are choosing an optimal treatment for carcinoma of the prostate. METHODS: The authors used clinical and quantitative pathology results from the biopsy specimens of 817 PCA patients who had been evaluated at a large national pathology reference laboratory. The pathology parameters that were measured included the number of positive cores, Gleason grades and score, percentage of tumor involvement, and the tumor location. The pathologic stage of these cases, as determined by results from radical prostatectomy, lymphadenectomy, or bone scan, categorized the PCA as either OC, non-OC due to capsular penetration only (NOC-CP) or advanced disease with metastasis (NOC-Mets), i.e., seminal vesicle and/or lymph-node positive or bone-scan positive. There were a total of 481 OC cases, 185 NOC-CP cases, and 151 NOC-Mets cases. Patient-specific prediction models were trained by ordinal logistic regression (OLOGIT) and genetically engineered neural networks (GENNs), and the resulting trained models were validated by biopsy information from an independent set of 116 PCA patients. RESULTS: When the authors applied a cutoff of >or= 35% for the n = 817 training set of OC, NOC-CP, and NOC-Mets predictive probabilities, the OLOGIT model predicted OC PCA with an accuracy of 91%, whereas the GENN model predicted the same with an accuracy of 95%. When the authors employed the n = 116 validation set (76 OCs, 31 NOC-CPs, and 9 NOC-Mets), the OLOGIT and GENN models correctly identified OC PCA with 91% and 97% accuracy, respectively. CONCLUSIONS: The value of combining patient pretreatment diagnostic pathology parameters to make predictions concerning the postoperative extent of pathology was illustrated clearly in this study. This finding further confirms the need to pursue such approaches for PCA disease management in the future, especially with the increasing prevalence of clinical T1c (American Joint Committee on Cancer, 1977) disease.

Biopsy↗

Genetic variability in susceptibility and response to toxicants.

Everyone has a unique combination of polymorphic traits that modify susceptibility and response to drugs, chemicals and carcinogenic exposures. The metabolism of exogenous and endogenous chemical toxins may be modified by inherited and induced variation in CYP (P450), acetyltransferase (NAT) and glutathione S-transferase (GST) genes. We observe that specific 'at risk' genotypes for GSTM1 and NAT1/2 increase risk for bladder cancer among smokers. Genotypic and phenotypic variation in DNA repair may affect risk of somatic mutation and cancer. Variants of base excision and nucleotide excision repair genes (XRCC1 and XPD) appear to modify exposure-induced damage from cigarette smoke and radiation. We are currently engaged in discovering genetic variation in environmental response genes and determining if this variation has any effect on gene function or if it is associated with disease risk. These and other results are discussed in the context of evaluating inherited or acquired susceptibility risk factors for environmentally caused disease.

Acetyltransferases↗

Personality disorders.

Some general recommendations can be made, collected from these subjective descriptions of personality types. Because determining an accurate psychiatric diagnosis is not the internist's aim, it is better for him or her to have a stance that generalizes to all patients, which can be refined as personality characteristics emerge. Tolerate the patient's affect (such as anger or anxiety), being firm and kind, rather than punitive or overinvested. Accept dependency and vulnerability. Accept and respect the underlying coping style. Understand that the patient's personality style is the best (and usually only) way he or she knows to have a relationship, including a relationship with the physician. Understand that personality traits additionally may have a function (e.g., to guard against anxiety or depression). Recognize that personality traits do not come in pure form. One personality trait is likely to blend into or overlap with other traits. Identify and treat any underlying symptom disorder, such as anxiety, depression, irritability, or thought disorder. Educate the patient clearly (and without patronizing) about medical illness. Document what was explained to the patient and how the patient responded, including dispassionate observations about behavior and emotional expression. Appreciate the patient's possible attachment to medical symptoms. Avoid arguments with patients who make unreasonable demands. Make timely judgments about whether or not to accede to a demand. When in doubt about a patient's honesty, give the patient the benefit of the doubt. Do not worry about being used because all patients use their physicians to some extent. Go to the limits of your tolerance for a patient's personality, but know your limits and refer to a colleague when you cannot work with the patient. Terminate an interaction and get help if there is a risk (or fear) of violence. Given the time it takes to manage the relationship and the psychiatric elements of treatment, a referral to a psychiatrist or other mental health professional often is wise if the patient will accept it. Include the mental health professional as part of the medical team. Although these various recommendations have been emphasized in connection with certain personality types, one can be flexible about their application in a variety of patients. It is important also to reiterate the limits of subjective descriptions. It is rare to find any of the aforementioned subjective descriptions in unmodified form; characteristics of more than one personality type usually appear in the same person. The descriptions are composites that provide a starting point for the physician. The physician should edit the composites based on experience with real patients. This article has described human characteristics and rough guidelines for helpful human responses and possible pharmacologic interventions. So equipped, the primary care physician may find it less troubling and more interesting to face the wide variation in human character.

Adaptation, Psychological↗

Standardization, analytical validation, and quality control of intermediate endpoint biomarkers.

Standardized processes should be used in the identification and development of intermediate endpoint biomarkers (IEB) for the prediction of patient-specific disease outcomes. Using our own experiences, we outline some of our standardized processes. Using computer-assisted image analysis, we developed a new biomarker of genetic instability, termed quantitative nuclear grade (QNG). The QNG biomarker is derived using nuclear images analyzed from the tumor areas of Feulgen-stained 5-microm biopsy or radical prostatectomy tissue sections. From the variances of 41 to 60 different nuclear size, shape, and chromatin organization features, a QNG solution is computed using either logistic regression or artificial neural networks. QNG can then be used as an input for models that solve for a patient-specific probability to accurately predict disease outcomes. Preoperatively, QNG predicted both the pathologic stage and progression of prostate cancer using biopsies (P <0.0001). Postoperatively, QNG proved extremely valuable in the prediction of biochemical progression using radical prostatectomy specimens with more than 10 years of follow-up (P <0.0001). We also demonstrate the identification of novel, differentially expressed, prostate cancer genes using RNA fingerprinting methods and the clinical utility of testing for these genes in both blood and tissue samples. Also illustrated is the improvement of serum biomarker performance by combining molecular forms of PSA with new biomarkers. In conclusion, the development of new IEBs requires planning based upon an understanding of the molecular pathogenesis of disease. IEB selection and clinical evaluation should employ standardized methods of testing and validation, followed by publication. QNG is 1 example of a new, highly predictive, IEB for prostate cancer that has been developed using these processes.

Analysis of Variance↗

Contemporary use of complexed PSA and calculated percent free PSA for early detection of prostate cancer: impact of changing disease demographics.

OBJECTIVES: To assess the diagnostic performance of complexed prostate-specific antigen (cPSA), total PSA (tPSA), and calculated free/total PSA (f/t PSA) ratios in the differentiation of benign disease from prostate cancer (CaP) using a contemporary patient cohort. METHODS: The cPSA, tPSA, and calculated fPSA values were determined using the Bayer Immuno-1 system. To validate our calculated f/t PSA ratio, we also retrospectively measured fPSA using the Abbott AxSYM immunoassay system in archival pretreatment sera obtained between 1990 and 1997 from 362 men with clinically and biopsy-confirmed benign prostatic hyperplasia (n = 179) or CaP (n = 183). The diagnostic utility of tPSA, cPSA, and the calculated f/t PSA ratio was assessed using a contemporary test population consisting of sera prospectively collected between June 1999 and June 2000 from 3006 men who had recently undergone a systematic biopsy by urologists in clinical practices throughout the United States. This contemporary patient sample had biopsy diagnoses of either no evidence of malignancy (n = 1857) or CaP (n = 1149). All serum samples had tPSA values between 2.0 and 20.0 ng/mL. RESULTS: The measured versus calculated f/t PSA ratios had a Pearson's correlation coefficient of 0.9130 in the retrospectively studied population of 362 men. The areas under the receiver operating characteristic curves (ROC-AUCs) for the measured and calculated f/t PSA ratios were indistinguishable (69.6% versus 69.2%, respectively). In the contemporary population (n = 3006), the ROC-AUC for tPSA, cPSA, and the calculated f/t PSA ratio was 52.2%, 53.9%, and 58.4%, respectively. We also compared the diagnostic performance using published cutoffs for tPSA (greater than 4.0 ng/mL), cPSA (greater than 3.8 ng/mL), and the f/t PSA ratio (greater than 15% and greater than 25%) in tPSA reflex ranges of 2 to 20 ng/mL and 2 to 10 ng/mL. We found that both cPSA and the f/t PSA ratio (greater than 25% cutoff) outperformed tPSA and yielded similar results in terms of biopsies spared and cancers missed. CONCLUSIONS: The calculated f/t PSA ratio and cPSA perform equally well in terms of the improvement of specificity in the discrimination of benign disease and CaP. The f/t PSA ratio and cPSA provide clinical benefits over the use of tPSA alone, such as an increased sparing of unnecessary biopsies performed with a manageable degree of risk of delayed cancer detection.

Area Under Curve↗

The effect of component placement on knee kinetics after arthroplasty with an unconstrained prosthesis.

The mechanical success of a total knee replacement demands stable patellar tracking without subluxation and, stable tracking, in turn, can depend largely on the medial-lateral forces restraining the patella. Patellar button medialization has been advocated as a means of reducing subluxation, and experimental evidence has shown femoral component rotation also affects medial-lateral forces. Surgeons have choices in femoral component rotation and patellar button medialization and must frequently make intra-operative decisions concerning component placement because of anatomical variations among patients. Thus, in seeking to minimize medial-lateral patellar force, we examined the effects of patellar button medialization and external femoral component rotation. The study used an unconstrained total knee system implanted in nine cadaveric specimens tested on a knee simulator operating through flexion angles up to 100 degrees. Tests included all combinations of external femoral component rotation of 0 degree, 2.5 degrees, and 5 degrees and patellar placement at the geometric center and at 3.75 mm medial to the geometric center. A video-based motion analysis system tracked patellar and tibial kinematics while a six-component load cell measured patellofemoral loads. Repeated measures analysis of variance revealed a statistically significant decrease in the average medial-lateral force with button medialization but no significant change with femoral component rotation. Neither femoral component rotation nor patellar button medialization had an effect on the normal component of the patellar reaction force. External femoral component rotation did cause significant increases in lateral patellar tilt, in tibial varus angle, and in external tibial rotation. Button medialization caused significant increases in lateral patellar tracking, lateral patellar tilt and external tibial rotation. The results in medial-lateral patellar forces quantify the benefit of patellar button medialization and discount any benefit of femoral rotation. The change in tibial kinematics with patellar button medialization and femoral component rotation cannot be measured in vivo with current technology, and the precise clinical implications are unknown.

Anterior Cruciate Ligament↗

Optimizing femoral component rotation in total knee arthroplasty.

Femoral component rotation is important in total knee arthroplasty to optimize patellofemoral and tibiofemoral kinematics. More recently, the epicondylar axis has been cited as the definitive landmark for femoral component rotation. However, there are few studies to support the validity of this rotational landmark and its effect on the patellofemoral and tibiofemoral articulations. In the current study, a total knee arthroplasty was done in 11 knees from cadavers. The knees were tested with various femoral component rotations from 5 degrees internal rotation to 5 degrees external rotation referenced to the epicondylar axis and to the posterior femoral condyles. Each knee acted as its own internal control. The knees were actively ranged from 0 degrees to 100 degrees by a force on the quadriceps tendon in an Oxford knee simulator. Three-dimensional kinematics of all three components were measured whereas a multiaxial transducer imbedded in the patella measured patellofemoral forces. Femoral component rotation parallel to the epicondylar axis resulted in the most normal patellar tracking and minimized patellofemoral shear forces early in flexion. This optimal rotation also minimized tibiofemoral wear motions. These beneficial effects of femoral rotation were less reproducibly related to the posterior condyles. Rotating the femoral component either internal or external to the epicondylar axis worsened knee function by increasing tibiofemoral wear motion and significantly worsening patellar tracking with increased shear forces early in flexion. Based on the current study, the femoral component should be rotationally aligned parallel to the epicondylar axis to avoid patellofemoral and tibiofemoral complications.

Analysis of Variance↗

Prozac weekly.

Explore the source record for details and available documents.

Antidepressive Agents, Second-Generation↗