PubMed Health⌕ Search

Biomedical subjects

M C Tracey

Publications and source records attributed to M C Tracey.

5 recordsLinked to original sources

Class II HLA allele polymorphism: DRB1, DQB1 and DPB1 alleles and haplotypes in the New Zealand Maori population.

Class II alleles of interest to transplantation comprise the DRB1, DQB1 and DPB1 loci. Sequence-based typing was used to determine the class II allelic variability present in New Zealand Maori, a population with close genetic ties to Polynesia and known anthropological and linguistic connections to mainland Asia. The most common DRB1 alleles identified were DRB1*1201, DRB1*110101, DRB1*0403 and DRB1*080302, with frequencies of 21.5%, 14%, 11.25% and 9.25%, respectively. Standard linkages between the DRB1 locus and the DRB3, 4 and 5 loci were maintained, with no novel patterns identified. The most common DQB1 alleles identified were DQB1*030101, DQB1*060101, DQB1*020101, DQB1*0602 and DQB1*050201, with frequencies of 29.5%, 8%, 7.8%, 6.4% and 6.2%, respectively. The most common DPB1 alleles identified were DPB1*0501, DPB1*040101 and DPB1*020102, with frequencies of 40.2%, 28.89% and 15.83%, respectively. A total of 80 estimated DRB1-DQB1 two-locus haplotypes were detected. DRB1*1201-DQB1*030101 was the most frequent (15.40%) haplotype, followed by DRB1*110101-DQB1*030101 (9.97%), DRB1*0403-DQB1*030201 (7.37%) and DRB1*080302-DQB1*060101 (5.96%). The allelic variation determined is being used in further analysis of the requirement for bone marrow transplantation in the New Zealand Maori population and has implications for optimal ethnic donor distribution on the New Zealand Bone Marrow Donor Registry, anthropological studies and disease association.

Alleles↗

Microfluidic solid phase suspension transport with an elastomer-based, single piezo-actuator, micro throttle pump.

We report a Micro Throttle Pump (MTP) which has been shown to pump 5 microm diameter polystyrene beads at a concentration of 4.5 x 10(7) beads ml(-1). This new MTP design is constructed in a straightforward manner and actuated by a single piezoelectric (PZT) element. Maximum flow rates at 800 Hz drive frequency of 132 microl min(-1) with water and 108 microl min(-1) with a bead suspension were obtained. Maximum back-pressures of 6 kPa were observed in both cases. The reported MTP employs specific location of distinct internal microfluid structures cast in a single compliant elastomeric substrate to exploit the opposing directions of flexure of regions of a piezoelectric-glass composite bonded to the elastomer. By this novel means, distinct flexural regions, exhibiting compressive and tensile stresses respectively, allow both the pump's integrated input and output throttles and its pump chamber to be actuated concurrently by a single PZT. To support MTP design we also report the characterisation of an individual throttle's resistance as a function of actuator deflection and discuss the underlying mechanism of the throttling effect.

Elastomers↗

Elastomer-glass micropump employing active throttles.

We report a reciprocating microfluidic pump, the Micro Throttle Pump (MTP), constructed in a relatively uncomplicated manner from glass and microstructured poly(dimethylsiloxane)(PDMS). Unconventionally, the MTP employs throttling of fluid flow as distinct from fully-closing valve structures. Accordingly, this technique offers the prospect of solid-phase suspension tolerance. The reported MTP employs piezoelectrically (PZT) actuated deformation of flow constrictions (throttles) fabricated from PDMS at the two ports of a central, PZT actuated pump chamber. By appropriate time-sequencing of the individual PZTs' actuation, pumping can be induced in either direction. PDMS' elasticity further facilitates throttle operation by virtue of allowing significant PZT flexure that is substantially independent of the underlying PDMS microstructure. In contrast, in a rigid substrate such as silicon, deformation is constrained to where underlying microstructured cavities exist and this restricts design options. We describe the construction and performance of a prototype MTP capable of pumping 300 microl min(-1) or alternatively generating a back-pressure of 5.5 kPa. Preliminary modelling of MTP operation is also presented.

Journal Article↗

A novel instrument for studying the flow behaviour of erythrocytes through microchannels simulating human blood capillaries.

A novel instrument has been developed to study the microrheology of erythrocytes as they flow through channels of dimensions similar to human blood capillaries. The channels are produced in silicon substrates using microengineering technology. Accurately defined, physiological driving pressures and temperatures are employed whilst precise, real-time image processing allows individual cells to be monitored continuously during their transit. The instrument characterises each cell in a sample of ca. 1000 in terms of its volume and flow velocity profile during its transit through a channel. The unique representation of the data in volume/velocity space provides new insight into the microrheological behaviour of blood. The image processing and subsequent data analysis enable the system to reject anomalous events such as multiple cell transits, thereby ensuring integrity of the resulting data. By employing an array of microfluidic flow channels we can integrate a number of different but precise and highly reproducible channel sizes and geometries within one array, thereby allowing multiple, concurrent isobaric measurements on one sample. As an illustration of the performance of the system, volume/velocity data sets recorded in a microfluidic device incorporating multiple channels of 100 microns length and individual widths ranging between 3.0 and 4.0 microns are presented.

Adult↗

A silicon micromachined device for use in blood cell deformability studies.

An application of silicon micromachining to the analysis of blood cell rheology is described. The system, based upon a micromachined flow cell, provides a specific measurement of each cell in a statistically significant population in terms of both flow velocity profile and an index of cell volume while the cells flow through an array of microchannels. The rationale, design, and fabrication of the silicon micromachined flow cell is discussed. Interrelated considerations determining the design of the associated fluidic, mechanical, imaging, and real-time image analysis subsystems are examined. Sample data comparing normal and iron deficiency anaemic blood are presented to illustrate the potential of this technique.

Blood Cells↗