PubMed Health⌕ Search

Biomedical subjects

M C Van Putten

Publications and source records attributed to M C Van Putten.

3 recordsLinked to original sources

Backscatter radiation at bone-titanium interface from high-energy X and gamma rays.

Occasionally head and neck cancer patients treated with high-energy X rays and gamma rays have titanium metal dental implants in their maxillae or mandibles. The resulting effect of the bone-metal interface on the radiation dose is of interest. Ionization measurements for 60Co gamma rays and 6 MV and 25 MV X rays were made. A thin-window parallel-plate chamber was used to determine the magnitude of the dose enhancement that was due to the backscattered electrons from titanium. The results showed that for 60Co there is a 15% increase in dose to solid bone at the entrance side of the titanium. For higher energy X rays, the increase in dose was about the same or slightly lower than for 60Co. Monte Carlo calculations substantiated the measurements. This increase in dose fell off rapidly and became negligible at 1-2 mm from the interface. This backscattered dose should be taken into account when planning radiation therapy treatment for patients with dental implants.

Bone and Bones↗

Titanates and zircoaluminates as coupling agents for dental cements.

This study attempted to bond glass-ionomer and zinc phosphate cements to a dental ceramic with the aid of a coupling agent and appropriate surface preparation. Four luting agents were shear tested after thermocycling: a glass-ionomer cement with three titanate coupling agents, three zircoaluminate coupling agents, and a silane coupling agent; a light-activated glass-ionomer cement with a silane coupling agent; a zinc phosphate with a titanate coupling agent; and the manufacturer's resin/silane as control. The light-activated glass-ionomer cement/silane coupling agent had the highest mean strength (3.8 MPa) followed by the control (3.7 MPa) and glass-ionomer/carboxy zircoaluminate (2.4 MPa). These measures were significantly (P < .05) higher than those of glass-ionomer/silane, zinc phosphate, and other lower ranking groups. Light-activated glass-ionomer cement was successfully bonded to dental ceramics. Carboxy zircoaluminate showed good results for bonding conventional glass-ionomer cement.

Aluminum↗

4-META polymethyl methacrylate shear bond strength to titanium.

Machined titanium substructures for fixed, complete arch prostheses have been used with various surface pretreatments to enhance acrylic bonding. Since traditional mechanical methods for denture base material retention cannot be used, silane and surface abrasives have been used to enhance retention. The purpose of this study was to determine if a metal bonding denture base material provided a favorable bond strength to machined titanium. Fifteen rod-shaped samples of commercially pure Grade 2 titanium were divided into two groups, five samples representing the control group and 10 samples for the experimental group. The rod samples for the control received no pretreatment, while the experimental samples were pretreated with 110 microns alumina abrasive. Meta-Dent heat-cured polymethyl methacrylate was processed around each sample in a secondary cylindrical shape approximately 0.9 x 1.0 centimeters with the titanium rods extending from each end. A Shell-Nielsen shear test was then performed at a crosshead speed of 0.5 millimeters/minute to determine the bond strength. The experimental group demonstrated a mean bond strength 3.7 times greater than the control group (significant, P = 0.0001, ANOVA). Pretreatment with 110 microns alumina air abrasive significantly enhanced the bond strength of heat-cured metal bonding polymethyl methacrylate to titanium.

Acrylic Resins↗