Assessment of local changes of cerebral perfusion and blood concentration by ultrasound harmonic B-mode contrast measurement in piglet.

This study tested the hypothesis that changes in the blood concentration, and possibly in the perfusion, of different areas in the brain can be assessed by the use of ultrasound contrast agent (CA) and (linear) echo densitometry. The experiments were performed with piglets (n=3) under general anesthesia and artificial ventilation. Ultrasound CA was administered through a femoral vein as a short bolus. First passage wash-in curve was measured from image gray level during continuous low level (mechanical index<0.2) ultrasound imaging. This curve was obtained from 1-cm2 areas of the cortex (surface), the brain stem (inner) and the left carotid artery (vessel). Cerebral hemoglobin concentration changes were measured with near-infrared spectroscopy (NIRS). This approach enabled a cross-validation of these techniques. The measurements were repeated under conditions of normocapnia, mild hypercapnia and deep hypercapnia. Several physiologic signals, as well as the carotid blood flow, were measured simultaneously and related to gray level by linear regression analysis. The most significant results found were a high R2-statistic of the regression of the percentage change of the peak of the surface and inner wash-in curves with the arterial carbon dioxide pressure (R2=0.63 and R2=0.70, respectively), the blood pH (R2=0.79 and R2=0.81), the carotid flow (R2=0.75 and R2=0.72) and the partial arterial oxygen pressure (R2=0.47 and R2=0.55). Finally, a high correlation of peak gray level with total hemoglobin concentration change, independently measured by NIRS, was found (R2=0.69). In conclusion, these experiments show a reasonable intersubject variability of various relative measures derived from gray level ultrasound wash-in curves. High sensitivity to physiologic changes related to hypercapnia was observed for the peak contrast of wash-in curves. For up-slope and area-under-the-curve (first passage) this was lower but still highly significant. The gray-level ultrasound measures are highly correlated to changes in regional hemoglobin concentration in brain tissue assessed by NIRS.

Animals↗

Performance testing of medical ultrasound equipment: fundamental vs. harmonic mode.

Assessment of the performance of medical ultrasound equipment is generally based on the image quality in fundamental mode. Recent development of the so-called tissue harmonic imaging (THI) mode induces the need for assessment of differences in the quality of imaging in THI vs. fundamental imaging mode. Quality features to be tested are sensitivity (penetration depth), spatial resolution, contrast resolution, lesion signal-to-noise ratio, and tissue-to-clutter ratio (TCR). These features are explained and examples are shown. The main conclusion from a comparison of the results for the two imaging modes might be that when using THI improvement of TCR, in particular in the near field, is obtained at the expense of a loss in axial resolution. Furthermore, lesion detection is not significantly improved.

Journal Article↗

Performance testing of medical echo/Doppler equipment.

This paper describes the methods applied in a software package developed by the authors for use in a performance testing protocol for medical ultrasound equipment. The history of performance testing of medical ultrasound equipment is briefly reviewed. This paper is confined to the testing of performance of usage aspects, i.e. imaging performance and Doppler velocity estimation performance. Simple test objects are used which have a long life expectancy. The tests performed both in fundamental and in (tissue) harmonic modes when applicable are spatial resolution, contrast sensitivity, and clutter. The concept of a computational observer is used to define the lesion signal-to-noise ratio and the tissue-to-clutter ratio. Further imaging performance features are penetration depth, slice thickness and geometric conformity of display. Pulsed Doppler velocity measurement features tested are: sensitivity, depth and 3D size of the sample volume, velocity measurement, channel separation. The whole performance measurement protocol as well as the quantitative measurements in the digitized images are implemented in software, together with the graphs and data obtained from the measurements.

Blood Flow Velocity↗