PubMed Health⌕ Search

Biomedical subjects

M Caswell

Publications and source records attributed to M Caswell.

9 recordsLinked to original sources

The kinetics of the tanning response to tanning bed exposures.

No clinical studies have been published documenting the development of pigmentation following the use of the Food and Drug Administration (FDA) recommended exposures from a tanning bed. Panelists were exposed three times weekly for eight weeks (24 exposures) using the FDA recommended exposure schedule. The initial tan was noted after only six exposures and quantitatively increased through the remainder of the study.

Adolescent↗

Pressure ulcers.

Explore the source record for details and available documents.

Callosities↗

Effect of patient age on tests of the acute-phase response.

Tests of the acute-phase response are used to screen for occult disease in the elderly, but there is little consensus as to their diagnostic value because of uncertainty as to the effect of age on reference ranges. We have therefore measured, as a function of age, the blood concentration of acute-phase proteins (C-reactive protein, alpha 1-acid glycoprotein, fibrinogen, albumin, and globulin) in parallel with three screening tests of the acute-phase response (erythrocyte sedimentation rate, plasma viscosity, and zeta sedimentation ratio). The study included 164 healthy individuals (age range, 25 to 84 years) plus 91 elderly ill but ambulant patients (age range, 65 to 84 years) from a family practitioner screening clinic. Reference ranges for the erythrocyte sedimentation rate, plasma viscosity, and zeta sedimentation ratio rose with age, with the erythrocyte sedimentation rate showing a particularly wide reference range. Healthy individuals aged 75 to 84 years, compared with those aged 65 to 74 years, showed a trend to a lower reference range for all three screening tests that may have reflected survival of the fittest individuals to the higher decade. Precise reference ranges are therefore required in the elderly; when these were used, the three screening tests showed a significant difference between elderly well and ill individuals.

Acute-Phase Proteins↗

Assessment of Diesse Ves-matic automated system for measuring erythrocyte sedimentation rate.

Measurement of the erythrocyte sedimentation rate (ESR) using a closed tube system reduces the biohazard risk to laboratory staff. The Diesse Ves-matic system offers manual or vacuum collection of blood into plastic tubes, automated mixing of the sample, and automated reading of the end point after 20 minutes of sedimentation. This system was compared with the 1977 Westergren ESR method of the International Council for Standardization in Haematology (ICSH) and with the 1988 ICSH undiluted ESR method. Manually collected Ves-matic samples showed good agreement with ICSH values, although there was a tendency to false low results at low ESR values which may represent dilution of plasma protein with excess citrate. Vacuum collected Ves-matic samples also showed good agreement with ICSH values, although there was a tendency to false high results which may reflect a change in the blood: citrate ratio caused by loss of anticoagulant diluent or vacuum from plastic tubes during storage. The Diesse Ves-matic system incorporates several improvements over previous technology and offers a safer, quicker, and more standardised ESR.

Acute-Phase Reaction↗

Evaluation of a 200 mm long vacuum aspiration tube for measurement of erythrocyte sedimentation rate.

The ESrT-system 200 comprises a 215 mm long vacuum aspiration venepuncture tube which contains anticoagulant diluent for the measurement of the erythrocyte sedimentation rate (ESR) without direct handling of the blood sample. This combines the advantage of a tube of "Westergren" length with a reduction in biohazard risk. Blood from 160 patients (ESR range 2-135 mm/first hour) was tested in parallel with the selected Westergren ESR method of the International Committee for Standardization in Haematology (ICSH) and a close correlation (r = 0.967) between the two methods was obtained. A second Westergren ESR, using anticoagulated but undiluted blood, was measured on 58 specimens to give an ICSH "expected" ESR. The ESrT-system 200 result was within 12 mm/first hour of the "expected" result for 91% of the specimens. This new ESR system is simple to use, does not require mathematical correction of the ESR reading for tube length, and gives results that are comparable with those obtained with the ICSH Westergren method.

Blood Sedimentation↗