PubMed Health⌕ Search

Biomedical subjects

M Catalá Icardo

Publications and source records attributed to M Catalá Icardo.

9 recordsLinked to original sources

Fluorescence determination of the pesticide asulam by flow injection analysis.

This paper presents the analytical determination of the pesticide Asulam based on its native fluorescence. The method was optimized in either a flow injection analysis (FIA) assembly or in batch. The maximum fluorescence intensity was observed for basic pH solutions and at a lamda(ex) of 258 nm and a lamda(em) of 342 nm. The influence of different empirical parameters, such as the pH, the presence of surfactants, solvent polarity or solved oxygen amount, was studied. The calibration range was fitted with a linear equation from 0.01-3 mg l(-1) Asulam and 0.005-15 mg l(-1) Asulam for batch and continuous-flow, respectively. The RSD for both procedures was 1.0%. After testing the influence of a large series of potential interferents, the method was applied to water samples from different locations.

Carbamates↗

Chemiluminescent determination of the pesticide bromoxynil by on-line photodegradation in a flow-injection system.

A new, robust and simple method is proposed for the chemiluminescent determination of the pesticide Bromoxynil. The empirical procedure is performed with the aid of a flow-injection manifold provided with an on-line photo-reactor to obtain chemiluminescent photofragments. After a period of 12 s of irradiation with an 8 W low-pressure mercury lamp, a chemiluminescent oxidation was performed with the system potassium permanganate in a polyphosphoric acid medium. The photolysis required a basic medium (KOH 0.014 mol l(-1)) with ethanol (1%) as a sensitizer. The method allowed the determination of 134 samples (h-1) of Bromoxynil in a wide interval of concentrations, over the range 5 x 10(-3) - 1 mg l(-1); the detection limit was 5 x 10(-3) mg l(-1). The RSD (n=24) at 0.25 mg l(-1) of the pesticide level was 2.3%. The method was applied to a water sample and to a formulation.

Flow Injection Analysis↗

In situ generation of Co(II) by use of a solid-phase reactor in an FIA assembly for the spectrophotometric determination of penicillamine.

A flow injection analysis (FIA) manifold for the determination of penicillamine in pharmaceutical preparations is proposed. The manifold includes a solid-phase reactor for the in situ production of the derivatizing reagent, Co(II) ion, which forms a coloured complex with penicillamine in an alkaline medium. The reactor is prepared by natural immobilization of cobalt carbonate on a polymer matrix, which endows it with a high mechanical and microbiological stability. The cobalt released by passage of a 5 x 10(-4) mol l(-1) sulphuric acid stream at a flow-rate of 2.3 ml min(-1) is merged with a volume of 314 microl of sample containing penicillamine in ammonium-ammonia buffer at pH 9.5 to measure the absorbance at 360 nm. Beer's law is obeyed over the penicillamine concentration range 5-60 mg l(-1). The limit of detection (LOD) of the method is 1 mg l(-1) and its throughput 70 samples h(-1).

Cobalt↗

FI-chemiluminometric study of thiazides by on-line photochemical reaction.

The present manuscript deals with a simple and sensitive flow-injection method for the chemiluminescent determination of thiazides. The method is based on the on-line photodegradation and chemiluminescent determination of the resulting photo-fragments. The on-line photodegradation is performed in basic medium by using a photoreactor consisting of a 550cm long x 0.8mm ID piece of PTFE tubing helically coiled around an 8W low-pressure mercury lamp. The determination of the photo-irradiated thiazides is performed by a chemiluminescent oxidative reaction with Ce(IV) in sulphuric acid medium. A heterogeneous group of thiazides (indapamide, metolazone, hydroflumethiazide, chlorthalidone and bendroflumethiazide) has been studied. Hydrochlorothiazide was selected as a test substance. The "on-line" photochemical reaction approach allows the sensitive chemiluminescent determination of thiazides which do not present native chemiluminescence in the absence of sensitizers such as Rhodamine 6G. Linear calibration graphs were typically over the range 0.5-12 microgml(-1) (indapamide, metolazone, hydroflumethiazide and chlorthalidone); and over the range 0.5-5 microgml(-1) (hydrochlorothiazide). Limits of detection ranged between 0.005 microgml(-1) (hydrochlorothiazide) and 0.06 microgml(-1) (bendroflumethiazide). The relative standard deviation for the test substance was 2.0% for 2 microgl(-1) of the drug (n = 11) and the throughput was 65 h(-1) in all cases. The assessment of the photodegradation step on the molecular structure of thiazides was established by recording UV and fluorimetric spectra. The viability of the on-line photoinduced fluorescent determination of hydroflumethiazide and bendroflumethiazide was confirmed. The method was also applied to the determination of hydrochlorothiazide in commercially available formulation.

Flow Injection Analysis↗

Automated simultaneous triple dissolution profiles of two drugs, sulphamethoxazole-trimethoprim and hydrochlorothiazide-captopril in solid oral dosage forms by a multicommutation flow-assembly and derivative spectrophotometry.

This article deals with the simultaneous determination of three dissolution profiles with the aid of the new and emerging continuous-flow methodology known as multicommutation. This methodology is based on a flow network of a set of solenoid valves controlled by the computer and acting as independent multicommutators to allow the easy and automated control of flowing solutions. The obtained three dissolution profiles from one dosage form are the whole formulation profile or "global profile" recommended by pharmacopoeias, and, at same time, are recorded two "individual" profiles from two drugs present in the formulation. This is the second attempt to obtain simultaneously three dissolution profiles with a single spectrophotometric detector and the first with the multicommutation methodology. The selected pharmaceutical formulations contained a couple of active principles with overlapped spectra, namely sulphamethoxazole and trimethoprim or hydrochlorothiazide and captopril. The obtained empirical plots profiles fitted with the Higuchi equation also known as the three-parameter equation.

Administration, Oral↗

Three simultaneous dissolution profiles on a solid pharmaceutical formulation by a FIA manifold provided with a single spectrophotometric detector.

This article deals with the simultaneous determination of three dissolution profiles in the same pharmaceutical formulation. The officially proposed procedure from the pharmacopoeias is adapted to the FIA methodology to obtain the officially recommended profile or "global profile", and two "individual" profiles, corresponding to dissolution rate of two different active principles present in the formulation; both drugs have overlapped UV-vis spectra. The simultaneous determination of several profiles is based on the derivative spectra and the zero crossing mathematical procedure for the "individual" profiles of an active principle; the "global" profile of the formulation is obtained from the order zero derivative. The empirical profiles were adjusted by regression analysis using the three-parameter (Higuchi equation) plot method which was selected as the most suitable. The analytical errors when the concentration of one drug is very small or very high are also checked.

Amoxicillin↗

Determination of nitrite by inhibition of the chemiluminescence of acriflavine in a flow-injection assembly.

The indirect determination of nitrite was performed with a flow-injection assembly on the basis of the inhibition of the analytical output obtained in a luminometer by oxidation of acriflavine. The acriflavine solution merged with the nitrite and the resulting mixture was injected into a pure water stream. This solution merged with the oxidant solution (potassium permanganate in sulfuric acid medium) and the resulting chemiluminiscence was affected (inhibited) by the presence of nitrite after reaction with the aminoacridine. The method was applicable over the range 10-800 microg l(-1) of nitrite with a correlation coefficient of 0.9960. The relative standard deviation was 1.4% and the throughput was 76 samples h(-1). The influence of foreign substances was also tested. A solid-phase reactor, filled with Amberlite IRA-900, was inserted in the assembly for the on-line preconcentration of nitrite; the analytical output resulted in an increase of up to 11.5-fold. The method was applied to the determination of nitrites in residual waters, industrial formulations and soil samples.

Acriflavine↗

o-Dianisidine: a new reagent for selective spectrophotometric, flow injection determination of chlorine.

A flow injection analysis (FIA) procedure for the determination of free chlorine in industrial formulations and water samples is proposed. The manifold is provided with a gas-diffusion unit which permits the removal of interfering species and also the preconcentration of chlorine. The determination of chlorine is performed on the basis of the oxidation by o-dianisidine as a chromogenic reagent to a coloured product which can be monitored at 445 nm. The method (for a preconcentration step of 60 s) is linear over the range 0.04-1.00 mg l(-1) of chlorine, the limit of detection is 0.04 mg l(-1), the reproducibility of the procedure (as RSD of the slope) is 3.7% for a series of four independent calibrations, the precision (as RSD of a series of 30 continuous FIA peaks of 0.56 mg l(-1) of chlorine) is 1.4% and the sample throughput is 40 h(-1). A detailed comparative study of the analytical characteristics of a single mono-channel reverse FIA assembly and the same system but provided with a Fluoropore membrane filter of 0.5 microm pore size was performed to check the advantages of the new approach in terms of sensitivity, selectivity and limit of detection.

Chlorine↗

Solid-phase reactors as high stability reagent sources in flow analysis: selective flow injection spectrophotometric determination of cysteine in pharmaceutical formulations.

The flow injection spectrophotometric determination of cysteine was carried out by reaction with cobalt(II) ions entrapped in a polymeric material and filling a packed-bed reactor; the released cobalt(II) complexed with the amino acid was monitored at 360 nm. The method worked with a high repeatability, even with independent reactors, days and solutions. Selectivity of the procedure was tested with twenty different foreign compounds found in pharmaceutical formulations containing cysteine, parent amino acids included; no serious interferences were observed. The calibration graph for cysteine was linear over the range 1-90 micrograms ml-1 with a relative standard deviation of 0.8% at 60 micrograms ml-1 (n = 158). The calculated sample throughput was 90 h-1. The method was applied to determine the content of cysteine in pharmaceutical formulations.

Cobalt↗