PubMed Health⌕ Search

Biomedical subjects

M Chiappalone

Publications and source records attributed to M Chiappalone.

2 recordsLinked to original sources

Networks of neurons coupled to microelectrode arrays: a neuronal sensory system for pharmacological applications.

Two main features make microelectrode arrays (MEAs) a valuable tool for electrophysiological measurements under the perspective of pharmacological applications, namely: (i) they are non-invasive and permit, under appropriate conditions, to monitor the electrophysiological activity of neurons for a long period of time (i.e. from several hours up to months); (ii) they allow a multi-site recording (up to tens of channels). Thus, they should allow a high-throughput screening while reducing the need for animal experiments. In this paper, by taking advantages of these features, we analyze the changes in activity pattern induced by the treatment with specific substances, applied on dissociated neurons coming from the chick-embryo spinal cord. Following pioneering works by Gross and co-workers (see e.g. Gross and Kowalski, 1991. Neural Networks, Concepts, Application and Implementation, vol. 4. Prentice Hall, NJ, pp. 47-110; Gross et al., 1992. Sensors Actuators, 6, 1-8.), in this paper analysis of the drugs' effects (e.g. NBQX, CTZ, MK801) to the collective electrophysiological behavior of the neuronal network in terms of burst activity, will be presented. Data are simultaneously recorded from eight electrodes and besides variations induced by the drugs also the correlation between different channels (i.e. different area in the neural network) with respect to the chemical stimuli will be introduced (Bove et al., 1997. IEEE Trans. Biomed. Eng., 44, 964-977.). Cultured spinal neurons from the chick embryo were chosen as a neurobiological system for their relative simplicity and for their reproducible spontaneous electrophysiological behavior. It is well known that neuronal networks in the developing spinal cord are spontaneously active and that the presence of a significant and reproducible bursting activity is essential for the proper formation of muscles and joints (Chub and O'Donovan, 1998. J. Neurosci., 1, 294-306.). This fact, beside a natural variability among different biological preparations, allows a comparison also among different experimental session giving reliable results and envisaging a definition of a bioelectronic 'neuronal sensory system'.

Algorithms↗

Computationally inexpensive methods for intra-cardiac atrial bipolar electrogram compression.

AIM: This paper reports studies of mathematical algorithms for intra-cardiac atrial bipolar electrogram compression suitable with implementation on implantable devices. PATIENTS AND METHODS: Bipolar intra-cardiac electrograms (IEGMs) of high right atrium were obtained from 20 patients who underwent electrophysiological studies for arrhythmias. Four thousand seven hundred and eighty-two seconds of IEGM were collected and divided into three rhythm groups: sinus rhythm (SR), atrial fibrillation (AF) and atrial flutter (AFL). Since mathematical algorithms suitable for use with implantable devices demand low computational cost, we employed piecemeal linear approximation methods (ZOP--Zero Order Prediction and SAPA--Scan Along Polygonal Approximation), and beat detection method (Peak) both or which need small numbers of operations to perform electrogram compression. Compression ratio (CR) and percent root mean square difference (PRD) were used to compare the three methods, with statistical analyses performed using paired t-test. RESULTS AND CONCLUSION: The best performance was obtained using the Peak method which reaches an average CR of 10.6 in the case of SR group, 2.8 for AF, and 3.6 for AFL groups, respectively, while PRD lies below 2% for SR and AFL groups and 6% for the AF group. Results show that, for bipolar electrograms, the Peak method reaches statistically significant better performance (P<0.001) in all cases except for Peak vs SAPA applied to AF (P=0.2). The number of operations necessary to compress the data indicate that time consumption can be reduced to be suitable for real time compression in implantable devices. The Peak method, which was assumed to receive the instant of occurrence of each recognized beat, from the hardware of the device, requires fewer operations than ZOP and SAPA. Increasing the length of electrograms recorded in pacemakers will enhance the amount of information provided by the implantable device, allowing more detailed characterization of the intra-cardiac activity and leading to new perspectives in arrhythmia diagnosis and therapy.

Adult↗