PubMed Health⌕ Search

Biomedical subjects

M Ciobanu

Publications and source records attributed to M Ciobanu.

At least 19 recordsLinked to original sources

Radical graft polymerization of styrene sulfonate on poly(ethylene terephthalate) films for ACL applications: "grafting from" and chemical characterization.

The purpose of this study is to develop a reliable method of functionalizing poly(ethylene terephthalate) with bioactive polymers to produce a "biointegrable" artificial anterior cruciate ligament. Radical graft polymerization of the sodium salt of styrene sulfonate (NaSS) onto poly(ethylene terephthalate) (PET) films was performed using the "grafting from" technique. Prior to the grafting, the surfaces of poly(ethylene terephthalate) films were activated by ozonation to generate peroxide and hydroperoxide reactive species on the PET film surfaces. The radical polymerization of NaSS was initiated by thermal decomposition of the hydroperoxides. The grafted PET surfaces were characterized by a toluidin blue colorimetric method, X-ray photoelectron spectroscopy, contact angle measurements, and atomic force microscopy. The influence of ozonation time, monomer concentration, and temperature on NaSS grafting ratios was examined. A total of 30 min of ozonation followed by grafting from a 15% NaSS solution at 70 degrees C for 90 min or more resulted in attachment of poly(NaSS) chains to the PET film surfaces.

Biocompatible Materials↗

Pulsed Doppler echocardiography in the diagnosis and estimation of severity of aortic insufficiency.

Detection and estimation of the degree of chronic aortic insufficiency with pulsed Doppler echocardiography was attempted in 27 patients documented to have aortic insufficiency on aortography. Twenty-five patients had associated aortic stenosis or mitral valve disease, or both. A disturbed diastolic flow within the left ventricular outflow tract was recorded in all but one patient (Doppler sensitivity 96 percent). Aortic insufficiency was clinically undetected in three patients (clinical sensitivity 89 percent). In a small number of patients Doppler echocardiography also appeared to be highly specific for this disorder. The Doppler technique estimated the degree of aortic insufficiency by assessing the distribution of diastolic flow within the outflow tract and the body of the left ventricle. A significant correlation between the Doppler method and the angiographic estimation of aortic insufficiency was found (r = 0.88, p less than 0.01).

Adult↗