PubMed Health⌕ Search

Biomedical subjects

M Conceição

Publications and source records attributed to M Conceição.

7 recordsLinked to original sources

Sequential injection chromatographic determination of paracetamol, caffeine, and acetylsalicylic acid in pharmaceutical tablets.

In this contribution, a new separation method for simultaneous determination of paracetamol, caffeine, acetylsalicylic acid, and internal standard benzoic acid was developed based on a novel reversed-phase sequential injection chromatography (SIC) technique with UV detection. A Chromolith Flash RP-18e, 25-4.6mm column (Merck, Germany) and a FIAlab 3000 system (USA) with an 8-port selection valve and a 5 mL syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-(0.01 M) phosphate buffer (10:90, v/v) pH 4.05, flow rate 0.6 mL min(-1). UV detection was at 210 and 230 nm. The validation parameters showed good results: linearity (r >0.999) for all compounds, detection limits in the range 0.3-0.8 microg mL(-1), repeatability (RSD) of peak heights between runs in the range 1.10-4.30% at three concentration levels and intra-day repeatability of the retention times in the range 0.28-0.43%. The analysis time was <6 min. The method was found to be applicable for the routine analysis of the active compounds paracetamol, caffeine, and acetylsalicylic acid in pharmaceutical tablets.

Acetaminophen↗

Chiral gas chromatographic separation of 2-oxabicyclo[3.3.0]octane derivatives and their synthetic precursors.

Chiral GC separation of (+/-)-2-allyl-2-carboethoxycyclopentanone (9) and the alcohols (+/-)-3-(hydroxymethyl)-5-carboethoxy-2-oxabicyclo[3.3.0]octane (7), (+/-)-2-allyl-2-carboethoxycyclopentanol (8), and their acetylated and trifluoroacetylated derivatives were investigated on three derivatized beta-cyclodextrins (CDs) diluted in SE-54 or 1701-OH: 2,3,6-tri-O-methyl-beta-CD (PMCD); 2,3-di-O-methyl-6-O-(tert-butyldimethylsilyl)-beta-CD (DIMETBCD); 2,3-di-O-acetyl-6-O-(tert-butyldimethylsilyl)-beta-CD (DIACTBCD). The understanding of these chiral separations is extremely relevant, since cyclopentanic and bicyclic cyclopentanic rings are common structural features of many important natural products and new pharmaceutical drugs. In general DIMETBCD diluted in SE-54 showed the best chiral resolution to alcohols 7 and 8 and only DIACTBCD showed enantioselectivity to 9. Hydrogen bonds prediction and dipole moments data were obtained by molecular modeling calculations for 7ab and 8ab and Ac and TFA derivatives. Comparison of these data with the chromatographic parameters for the related compounds were used to explain the differences of their elution orders and diastereo- and enantiomeric separations on the above chiral stationary phases (CSPs). The results suggest that the CSPs enantioselectivities are not affected by the carboethoxy-functionalized cyclopentanic and bicyclic cyclopentanic rings themselves but mainly by the functional group on the other stereogenic center.

Bridged Bicyclo Compounds, Heterocyclic↗

Tetracycline, oxytetracycline and chlortetracycline determination by flow injection potentiometry.

This paper describes tetracycline (TCH), oxytetracycline (OTCH) and chlortetracycline (CTCH) determination by flow injection potentiometry. In the flow system proposed TC samples are inserted in a carrier solution and converged with a Cu(II) solution of known concentration; the Cu(II) decrease due to its complexation with tetracyclines (TC) was monitored. The detector used was a homogeneous crystalline CuS/Ag2S double membrane tubular electrode with increased sensitivity. The present system allows tetracyclines determinations within a 48.1-4.8 x 10(3) ppm for TCH, 49.1-4.9 x 10(3) ppm for OTCH and 51.5-5.1 x 10(3) ppm for CTCH and a precision better than 0.4% for the three TC species. This procedure accomplishes 150-200 samples h(-1) with a Cu(II) consumption of about 13 microg determination(-1).

Chlortetracycline↗

Vitamins B1 and B6 tubular electrodes as FIA detectors; their use in the analysis of pharmaceutical products.

Ion-selective electrodes without an inner reference solution and tubular potentiometric detectors for the determination of vitamins B1 and B6 in pharmaceutical preparations by flow injection analysis (FIA) are reported. The membranes were prepared with the vitamin tetra(2-chlorophenyl)borate (TCPB) dissolved in o-nitrophenyloctyl ether (o-NPOE) and immobilized on PVC. Intrinsic behaviour of the tubular detectors was assessed using a low-dispersion single-channel FIA manifold and was compared with conventionally-shaped electrodes using the same membrane. Data obtained in the determination of vitamins B1 and B6 in pharmaceutical preparations with a double channel flow injection manifold incorporating the tubular detectors are presented and compared with those obtained by the U.S. Pharmacopeia method and by direct potentiometry with conventionally-shaped electrodes.

Electrodes↗

[Benzoate determination in medicinal syrups with a PVC membrane ion selective electrode without inner reference solution].

Two electrodes sensitives to benzoate ion, without inner reference solution, in which tetraoctylammonium benzoate in dibutylphtalate (type A) or 2-nitrophenyloctylether (type B) immobilized in PVC are used in membranes, applied on a conductive support, were prepared. The response characteristics and behaviour of this low-cost electrodes are presented. The analytical application possibilities are discussed and shown as practical examples on analyses of the ion in medicals syrups.

Benzoates↗

Solid-state PVC flow-through benzoate electrode.

A general construction procedure for conventional shape ion-selective electrodes based on a conductive support prepared with a mixture of a non-conductive epoxy and graphite was used in the preparation of a flow-through benzoate electrode to be used as potentiometric detector in flow injection analysis manifolds. The membranes were prepared from tetraoctylammonium benzoate in o-nitrophenyloctylether immobilized on PVC. The results of the assessment of the tubular electrodes behaviour in low dispersion manifolds against that of conventional electrodes with the same membrane are reported. Data obtained with a double-channel flow injection manifold incorporating these tubular detectors for benzoate determinations in several commercially available pharmaceutical preparations are also presented.

Benzoates↗

Atmospheric impact assessment and monitoring of dioxin emissions of municipal solid waste incinerators in Portugal.

In Portugal two municipal solid waste (MSW) incinerators are under construction in the metropolitan areas of Lisbon and Porto. During the development of the Environmental Impact Assessment (EIA) studies of these units the authors found several limitations and uncertainties associated to the assessment of the environmental impact. Uncertainties were particularly felt on the assessment of the environmental impacts associated with the atmospheric emissions of PCDD and PCDF. At present an External Monitoring Plan is under design.

Air Pollution↗