PubMed Health⌕ Search

Biomedical subjects

M Cortina

Publications and source records attributed to M Cortina.

7 recordsLinked to original sources

A sequential injection electronic tongue employing the transient response from potentiometric sensors for anion multidetermination.

Intelligent and automatic systems based on arrays of non-specific-response chemical sensors were recently developed in our laboratory. For multidetermination applications, the normal choice is an array of potentiometric sensors to generate the signal, and an artificial neural network (ANN) correctly trained to obtain the calibration model. As a great amount of information is required for the proper modelling, we proposed its automated generation by using the sequential injection analysis (SIA) technique. First signals used were steady-state: the equilibrium signal after a step-change in concentration. We have now adapted our procedures to record the transient response corresponding to a sample step. The novelty in this approach is therefore the use of the dynamic components of the signal in order to better discriminate or differentiate a sample. In the developed electronic tongue systems, detection is carried out by using a sensor array formed by five potentiometric sensors based on PVC membranes. For the developed application we employed two different chloride-selective sensors, two nitrate-selective sensors and one generic response sensor. As the amount of raw data (fivefold recordings corresponding to the five sensors) is excessive for an ANN, some feature extraction step prior to the modelling was needed. In order to attain substantial data reduction and noise filtering, the data obtained were fitted with orthonormal Legendre polynomials. In this case, a third-degree Legendre polynomial was shown to be sufficient to fit the data. The coefficients of these polynomials were the input information fed into the ANN used to model the concentrations of the determined species (Cl-, NO3- and HCO3-). Best results were obtained by using a backpropagation neural network trained with the Bayesian regularisation algorithm; the net had a single hidden layer containing three neurons with the tansig transfer function. The results obtained from the time-dependent response were compared with those obtained from steady-state conditions, showing the former superior performance. Finally, the method was applied for determining anions in synthetic samples and real water samples, where a satisfactory comparison was also achieved.

Algorithms↗

Time and space patterns of volatile organic compounds in a sewage treatment plant.

47 regulated and non-regulated volatile organic compounds (VOCs) were characterised by closed-loop stripping analysis (CLSA) and high resolution gas chromatography coupled to mass spectrometry (HRGC/MS) in 28 aqueous samples from 4 sampling points along a sewage treatment plant in Manresa, Catalonia, Spain. A 4 x 2(2) factorial design (16 samples) was first prepared for the sampling, and reinforced with 12 additional samples at the plant influent. The total analyte weighted mean concentration was 232 microg x l(-1) at the plant influent, with a mass flow of 2231 kg x yr(-1). Petroleum solvents and terpenic compounds accounted for 79% of the influent analyte concentration. VOC concentration in influent was clearly higher for most VOCs from 12 to 22 h (high organic load hours), and lower from 24 to 10 h (lower organic load). Differences between time bands were confirmed through t tests. Differences between weekdays and the weekend were not so clear, and could not be confirmed through t tests. VOC concentrations along the plant are discussed. Overall analyte removal in the plant was 89%.

Environmental Monitoring↗

Effects of variations in the proportions of saturated, monounsaturated and polyunsaturated fatty acids in the rat diet on spleen lymphocyte functions.

To obtain further information about the immunomodulatory effects of specific dietary fatty acids, weanling male rats were fed for 6 weeks on high-fat (178 g/kg) diets which differed according to the principal fatty acids present. The nine diets used differed in their contents of palmitic, oleic, linoleic and alpha-linolenic acids; as a result the total polyunsaturated fatty acid (PUFA) content and the PUFA:saturated fatty acid ratio varied (from 17.8 to 58.5 g/100 g fatty acids and from 0.28 to 5.56 respectively). The n-6 PUFA:n-3 PUFA ratio was kept constant in all diets at approximately 7.0. The fatty acid composition of the serum and of spleen lymphocytes were significantly influenced by that of the diet fed. The ex vivo proliferation of spleen lymphocytes decreased as the level of oleic acid in the diet increased. Spleen natural killer cell activity decreased as the oleic acid content of the diet increased and increased as the palmitic acid content of the diet increased. The extent of the effects of these fatty acids on lymphocyte functions was modified by the nature of the background fatty acid composition of the diet.

Animals↗

The value of quantitative detection of HBV-DNA amplified by PCR in the study of hepatitis B infection.

BACKGROUND/AIMS: This study aimed to evaluate the usefulness of quantifying HBV-DNA amplified by polymerase chain reaction in chronic hepatitis B infection. METHODS: Serum samples were obtained from 32 asymptomatic HBV carriers and 99 chronic hepatitis B patients (62 positive for anti-HBe and 37 positive for HBeAg). In addition, serial serum samples were analyzed from 15 HBeAg positive patients undergoing antiviral therapy and 17 anti-HBe positive patients with precore mutation. HBV-DNA quantification was carried out using an enzyme immunoassay with an HBV-DNA plasma standard. RESULTS: The digoxigenin-incorporated polymerase chain reaction method detected HBV-DNA in 34.3% of the asymptomatic HBV carriers with a median HBV-DNA concentration of about 0.18 x 10(5) mol/ml (range 0.08-0.4), in 87% of the anti-HBe positive chronic hepatitis cases with a range of 0.2 to > 2 x 10(5) mol/ml and in 100% of the HBeAg positive patients, with a value in all cases over 2 x 10(5) mol/ml. We observed that after treatment, HBV-DNA tested negative in only two of the eight HBeAg positive chronic hepatitis patients who seroconverted to anti-HBe, and was positive in the seven remaining, with a median HBV-DNA value of about 0.2 x 10(5) mol/ml (0.09-0.4). In the precore mutants HBV-DNA values ranged from 0.2 to > 2 x 10(5) mol/ml. CONCLUSIONS: Polymerase chain reaction HBV-DNA quantification is a sensitive method for managing chronic hepatitis B patients, especially those with low viremia, and may be a valuable tool for evaluating the efficacy of antiviral therapy.

Adult↗

[Long term follow-up of non-symptomatic HBsAg carriers].

232 asymptomatic HBsAg carriers were controlled between May/1986 and May/1990. The were detected in our blood bank between 1974 and 1976 or during pregnancy or delivery period after 1981. 23 of 232 (10%) became negative during the follow-up, this happening more frequently in carriers after 5 years of follow-up. Only 2 of 209 carriers with HBsAg were HBeAg positive and 1 of these was also DNA-VHB positive. None of the HBeAg negative carriers showed DNA-VHB; only 5 had increased transaminases. 7 were anti-VHC positive, these individuals experiencing more frequent increases in transaminases. The results of this study suggests that the determination of transaminases, viral activity markers, anti-HD, anti-VHC in HBsAg carriers are enough to identify those with hepatic disease.

Adolescent↗