PubMed Health⌕ Search

Biomedical subjects

M Cosson

Publications and source records attributed to M Cosson.

At least 19 recordsLinked to original sources

[Tissue resistance: what about tension-free?].

OBJECTIVES: The purpose is to quantify objective tissue resistances before healing of prostheses used in pelvic floor surgery. PATIENTS AND METHODS: We measured tissue resistances offered to five types of meshes by four classical surgical routes. We also tested the incidence of the modification of the width of meshes on tissue resistance. This study was realized on frozen cadavers, by pull on prostheses just after implantation. Tests are realized with a dynamometer and results obtained in Newton. RESULTS: In the Retzius space, TVT offers a better resistance than IVS or LIFT meshes. We did not bring to the fore a significant difference between four routes for 1 cm wide prosthesis. The increase of width of Prolene meshes improves their resistance in tissues and thus quality of their fixation. We underscore a better resistance of the trans sacrospinous route with regard to the trans muscular one. DISCUSSION AND CONCLUSION: The increase of resistance is bound to the increase of the contact area between the prosthesis and the tissues. This increase of resistance should be taken into account in prolapse surgery: constraints are stronger than for stress incontinence. The posterior arms of meshes have to measure more than 1 cm wide and be set up through the sacrospinous ligament rather than through the elevator muscles. The type of knitting of prostheses is important and influences the resistance in tissues in the immediate postoperative time. Manufacturers should be interested in conceiving specific meshes for the tension-free fixation, with special and adapted mechanical properties.

Cadaver↗

Transvaginal repair of genital prolapse: preliminary results of a new tension-free vaginal mesh (Prolift technique)--a case series multicentric study.

Our goal was to report the preliminary results of a transvaginal mesh repair of genital prolapse using the Prolift system. This retrospective multicentric study includes 110 patients. All patients had a stage 3 (at the hymen) or stage 4 (beyond the hymen) prolapse. Total mesh was used in 59 patients (53.6%), an isolated anterior mesh in 22 patients (20%) and an isolated posterior mesh in 29 patients (26.4%). We report one bladder injury sutured at surgery and two haematomas requiring secondary surgical management. At 3 months, 106 patients were available for follow-up. Mesh exposure occurred in five patients (4.7%), two of them requiring a surgical management. Granuloma without exposure occurred in three patients (2.8%). Failure rate (recurrent prolapse even asymptomatic or low grade symptomatic prolapse) was 4.7%. According to the perioperative and immediate post-operative results, Prolift repair seems to be a safe technique to correct pelvic organ prolapse. Anatomical and functional results must be assessed with a long-term follow-up to confirm the effectiveness and safety of the procedure.

Adult↗

[MRI evaluation of surgical pelvic floor repair].

OBJECTIVE: To bring to the fore the differences in terms of anatomical restoration between the abdominal and vaginal approach of pelvic floor repair. We compared the short-term anatomical results of the sacropexy and the sacrospinous fixation and paravaginal repair. PATIENTS AND METHODS: Magnetic Resonance Imagery (MRI) allowed us to obtain a reproducible and objective comparison of location of the various pelvic organs. Forty-three patients benefited from a MRI a pre- and postoperative evaluation according to the position of organs with regard to the pubo-coccygeal line. We noted cystocele, hysterocele or enterocele when the bladder, the uterine cervix, or the Douglas' cul-de-sac came under this line during efforts of push. We measured length modifications and lateral and anteroposterior vaginal axis. RESULTS: After the surgery, we noted that all pelvic organs were found above the reference line. On the other hand, bladders are significantly situated less high after vaginal pelvic floor repair. There is no postoperative difference as regards of the vaginal wall location. The lengths and vaginal axis are comparable in pre- and postoperative evaluation. DISCUSSION AND CONCLUSION: In our study, the anatomical results of pelvic floor repair performed by vaginal or abdominal route are short-term comparable and the vaginal approach is not responsible for decrease of length or vaginal reorientation. Standardized and longer term evaluated, the MRI can represent an objective and reproducible help to the staging of pelvic floor dysfunction.

Female↗

[Management of endometriosis of the urinary tract].

Endometriosis of the urinary tract (bladder and/or ureter) is rare and concerns 1-2% of cases of endometriosis. Surgical management is usually mandatory. Rate of peri operative morbidity is low. There is a risk of functional (dysuria, chronic hypogastric pains, imperiosity) and anatomical recurrences (0-15 and 0-10% respectively). Surgical treatment of bladder and/or ureteral endometriosis requires informed consent of patients and multidisciplinary management.

Cystectomy↗

[Subtotal hysterectomy: evolving concepts with implications for practice].

INTRODUCTION: The advantages and drawbacks of total and sub-total hysterectomy remain a topic of debate. Our study reviews the literature concerning recent comparative and prospective studies regarding the options of total and subtotal hysterectomy. RESULTS: Subtotal hysterectomy may be useful in preventing severe complications when total hysterectomy is technically difficult. Furthermore, conservation of the uterine cervix may decrease vaginal erosion in genital prolapse repair when synthetic meshes are used. The type of technique does not appear to determine the persistence or development of problems related to sexual activity (frequency of intercourse, sexual desire, and achievement of orgasm). There are no apparent advantages to subtotal hysterectomy compared with total hysterectomy with respect to bowel or bladder function. Some women (5-20%) who had the subtotal procedure continued to have genital bleeding, although this can be avoided with endocervical electro-coagulation or resection. Cervical stump prolapse is uncommon (1.5-2%), 12 months after subtotal hysterectomy. The risk of carcinoma of the cervical stump is low, and treatment results are similar in both patients with carcinoma of the cervical stump and in patients with carcinoma of the intact uterus. CONCLUSION: When subtotal hysterectomy is necessary, it can be performed with a low rate of long term complications. Furthermore, for women undergoing hysterectomy for benign disease, it should be reasonable to discuss advantages and drawbacks of both procedures and offer a choice. Nevertheless, sub-total hysterectomy should be avoided in populations with restricted access to screening programs for cancer of the uterine cervix.

Female↗

[Synthetic meshes for transvaginal surgical cure of genital prolapse: evaluation in 2005].

Since 1996, prosthetic meshes have become increasingly popular for transvaginal surgical cure of genital prolapse. In light of the growing number of proposed techniques and materials we reviewed the experience of the pioneers in order to provide surgeons with the most objective information available. We reviewed the literature indexed in Meline/PubMed and Current Contents retaining all work concerning resorbable and non-resorbable meshes. For the larger class of non-resorbable meshes we also reviewed articles by category of material, each type of mesh being carefully defined: different compositions of polypropylene, polyester, composite meshes and also insertion kits. Resorbable meshes were evaluated in two randomized studies which did not demonstrate better results than with simple folding known to have a high rate of recurrence. For polypropylene meshes, Marlex was studied in six trials which demonstrated a high rate of cure at one year but also a high rate of erosion which reached 25%. Use of Atrium was mentioned in three studies with a 6 to 12% recurrence rate and an erosion rate nearly reaching 20%. The majority of studies used Prolene and Gynemesh. Seventeen authors reported their experience, generally reviewing retrospective series, with recurrence rates of less than 10% for follow-up periods rarely greater than two years. A large variety of forms and sizes have been used, hindering comparisons. The rate of erosion was also quite variable, as high as 45%, demonstrating the need for a precise definition of erosion. Only recently have authors shown interest in the impact of prosthetic meshes on quality of life and sexual activity. An improvement is generally noted for defecation but the rate of dyspareunia has reached as high as 60%. Here again grades of prosthetic retraction should be better defined. Proposed to improve these phenomena, soft Prolene recently used by several authors does not appear to fulfil expectations. Since 2005, several precut polypropylene meshes have been proposed with an insertion kit. The Prolift kit has been followed prospectively in 100 patients undergoing regular surveillance. Surgipro has been used sporadically in small series but follow-up is still too short for proper assessment. Polyester meshes (Mersilene and Paritex) have been presented by three authors who have found them useful but reports have been vague concerning results and complications. Polytetrafluoroethylene has not been evaluated for transvaginal surgery, probably because of the poor tolerance of suburetral bands. For composite meshes, Vypro has been used by four authors who noted about 10% erosion but with a short follow-up insufficient to draw conclusions about the functional and anatomic outcome. Surfaced meshes, advocated for transvaginal treatments, have been studied in only two reports. Plevitex is a polypropylene mesh coated with collagen; another polyester composite with polyglactin 910. The rate of dyspareunia varied from 14 to 24%. Other composites with antiadherents or antiseptics are also proposed for transvaginal insertion but have not been studied. This work demonstrated the lack of sufficient evidence from prospective randomized trials and the lack of standardized techniques to draw any definite conclusions. While evidence is being accumulated on the lower rate of recurrence for anterior compartment prolapse, the lack of data on the rate of complications and patient quality of life is unacceptable for this functional surgery. We still have reservations about widespread use of synthetic meshes. A special chapter is detailed in appendix on post-operative complications. These new specific complications call to a new semiology, with a classification in 4 types and under-types, proposed by authors. Type 1: defects of healing. Type 2: the infection of the graft. Type 3: the shrinkage of the mesh. Type 4: erosions. Authors detail the symptoms of these 4 types as well as the prevention and the treatment of these complications.

Absorbable Implants↗

[Transvaginal surgery for genital prolapse in women aged over 80 years: Results in 48 procedures].

OBJECTIVES: The aim of this study was to assess the morbidity and the effectiveness of the vaginal surgical treatment for women over 80 years of age with genital prolapse. MATERIALS AND METHODS: All the women over 80 years operated in our institution between 1996 and 2003 were reviewed retrospectively. We examined the risk and the effectiveness of this surgery. RESULTS: Forty-eight women underwent surgery during this period. No colpocleisis was performed. The most frequent surgery was a combination of vaginal patch plastron, Richter's spinous fixation and posterior perineorrhaphy. No major intra- or post-operative complication occurred. One woman required blood transfusion. The most frequent postoperative complication was voiding difficulties (12%), which had disappeared 3 months later. A partial stenosis of a left ureter with ureterohydronephrosis occurred, requiring endoscopic dilatation. At 3 months, anatomic and functional outcome was good in 92% of women. The number of patients lost to follow-up at one year was to large to draw any conclusion. CONCLUSION: Complete transvaginal surgical treatment is a safe procedure for elderly women which provides good short-term effectiveness.

Aged, 80 and over↗

[Acceptability of intrauterine levonorgestrel delivery system (Mirena 52mg) after estrogen-progesterone oral contraception: results of a prospective multicentric study of 211 patients aged 25-35 years].

INTRODUCTION: Use of an intrauterine levonorgestrel (SIU-LNG) delivery system (Mirena 52mg has become popular in recent years, particularly among younger women. Mirena is currently the contraceptive method of choice used as an alternative to classical copper-containing intrauterine devices after oral contraception. The purpose of this study was to evaluate patient satisfaction among young women during the first year of use of the intrauterine hormonal system. MATERIAL AND METHODS: This multicentric phase IV trial with a non-comparative methodology was conducted among 211 young women aged 25-35 years. The SIU-LNG was prescribed for women who wanted to change their contraception after oral estrogen progesterone taken for at least three months prior to inclusion in the study. A total of 211 patients were included and review was planned at one year: 197 patients (93.36%) were reviewed. RESULTS: Mean patient age was 31.48+/-3.25 years. The SIU-LNG was inserted successfully at the first attempt in 99.05% of women. The continuation rate ws 85.65% at one year. Evaluation of cycle characteristics showed less voluminous blood loss and fewer dysmenorrheal phenomena as well as, in 40%, the development of amenorrhea. At the last visit, 85% of women were satisfied or very satisfied with this method of contraception. CONCLUSION: As has been demonstrated in earlier studies, Mirena offers a contraception with a reliability equivalent to that of oral estrogen progesterone (IP: 0 - 0.2), with very few hormonal side effects due to the low plasma passage of levonorgestrel. Mirena is particularly well adapted for young women who desire a reliable long-term easty-to-use contraception after taking oral contraception.

Adult↗

Efficacy and complications in the surgical treatment of stress urinary incontinence by insertion of a silicone-coated polyester tape (Lift).

OBJECTIVES: To evaluate the efficacy and safety of a surgical treatment for stress urinary incontinence by implantation of a silicone-coated polyester tape (Lift). MATERIALS AND METHODS: This retrospective study included 72 female patients having had a suburethral silicone-coated polyester tape inserted as treatment for stress urinary incontinence, combined or not with pelvic surgery. We recorded the patient's characteristics, the surgical procedure, the short and long-term results and complications. RESULTS: Seventy-two patients were operated, 60 of whom were fully evaluated. The average follow-up was 17 months. On 48 patients (80%) the treatment was successful, 3 (5%) were improved, and 9 (15%) were regarded as a failure. Dysuria occurred in six (10%) patients, five were de novo, and one was persistent. Ten patients (16.6%) presented de novo urge incontinence. The main complication was a higher rate of severe infections, accompanied by defective healing (4, i.e. 6.7%). CONCLUSION: The procedure using a silicone-coated polyester tape seems to be efficient, but insufficiently secure. This higher rejection rate leads us to prefer other synthetic materials proved to be better tolerated.

Coated Materials, Biocompatible↗

Perineal cellulitis following trans-obturator sub-urethral tape Uratape.

OBJECTIVE: We report two cases of perineal cellulitis due to the surgical treatment of female stress urinary incontinence with a trans-obturator sub-urethral tape of Uratape (Porgés). METHODS: Treatment and follow up of their complication were performed at the CHRU of Lille. RESULTS: In both cases, this complication is related to prolonged vaginal exposition of the tape. Vaginal erosion always occurs next to the silicon coated section of the tape. CONCLUSION: Such a complication has never been described yet. It shows a lack of data concerning human tissue tolerance of sub-urethral tapes constituents. Such examples should call for caution against new materials, all the more so as they have not yet been validated by large scale studies.

Adult↗

[Strategy for management of ovarian immature teratoma. About three cases and review].

Ovarian immature teratoma is a malignant germ cell tumor and represents less than 1% of ovarian malignant tumors. Tissues are derived from the three germ layers (endo-, meso- and ectoderm). Tumor grading is based on the amount of immature neuroepithelium present. The prognosis is directly correlated to histologic grade. Rapid growth leads to large tumors with an early diagnosis. Therapeutic management is balanced between adjuvant chemotherapy and surgery alone. Nevertheless, as immature teratoma mostly occurs in young women, the main objective is to preserve fertility.

Adult↗

[Risk factors for prosthesis exposure in treatment of genital prolapse via the vaginal approach].

OBJECTIVES: Prosthetic reinforcement in the surgical repair of pelvic prolapse by the vaginal approach is currently on the increase. However, this technique is not without tolerance-related problems. The most frequently described complication is prosthesis exposure, including erosion and delayed healing. It is independent of a granuloma and a major infection as pelvic cellulitis. Its mechanism is associated with defective vaginal healing. The purpose of our study is to define the risk factors for exposure of the prosthetic material. PATIENTS AND METHODS: Two hundred and seventy-seven medical records relating to patients undergoing surgery due to pelvic prolapse were included in our study. The treatment of genital prolapse was managed via the vaginal approach with polypropylene mesh. This is a continuous, retrospective study conducted over a period of 24 months. RESULTS: Thirty-four cases of prosthesis exposure were observed in the 2 months following surgery, which represents an incidence of 12.27%. The risk factors are concomitant hysterectomy [odds ratio 5.17 (P = 0.001)] and inverted T colpotomy [odds ratio 6.06 (P = 0.01)]. The protective factors are preservation of the uterus and the performance of a minor colpotomy in patients who had already undergone a hysterectomy or in those whose uterus had been preserved [odds ratio 5.16 (P = 0.0001)]. DISCUSSION AND CONCLUSION: In our study, we have only found risk factors of operative protocol. In fact, other information as age, menopause status or medical history of the patient is not significant. The uterus must be preserved and the number and extent of colpotomies needed to insert the prosthesis must be limited.

Adult↗