PubMed Health⌕ Search

Biomedical subjects

M Cova

Publications and source records attributed to M Cova.

At least 19 recordsLinked to original sources

Magnetic resonance diffusion-weighted imaging: extraneurological applications.

Diffusion-weighted (Dw) imaging has for a number of years been a diagnostic tool in the field of neuroradiology, yet only since the end of the 1990s, with the introduction of echoplanar imaging (EPI) and the use of sequences capable of performing diffusion studies during a single breath hold, has it found diagnostic applications at the level of the abdomen. The inherent sensitivity to motion and the magnetic susceptibility of Dw sequences nonetheless still create problems in the study of the abdomen due to artefacts caused by the heartbeat and intestinal peristalsis, as well as the presence of various parenchymal-gas interfaces. With regard to focal liver lesions, a review of the literature reveals that Dw imaging is able to differentiate lesions with high water content (cysts and angiomas) from solid lesions. With regard to the latter, although there are differences between benign forms [focal nodular hyperplasia (FNH), adenoma] and malignant forms [metastasis, hepatocellular carcinoma (HCC)] in their apparent diffusion coefficient (ADC) in the average values for histological type, there is a significant overlap in values when lesions are assessed individually, with the consequent problem of their correct identification. One promising aspect is the possibility of quantifying the degree of fibrosis in patients with chronic liver disease and cirrhosis given that the deposit of collagen fibres "restricts" the motion of water molecules and therefore reduces ADC values. However, even in this field, studies can only be considered preliminary and far from real clinical applications. The retroperitoneum is less affected by motion artefacts and similarly deserves the attention of Dw imaging. Here it is possible to differentiate mucin-producing tumours of the pancreas from pseudocystic forms on the basis of ADC values even though the limited spatial resolution of Dw imaging does not enable the identification of small lesions. Dw imaging may be applied to the study of the kidney to differentiate hydronephrosis from pyonephrosis and with regard to tumours, solid from pseudocystic forms. In addition, given that renal parenchyma has significantly variable ADC values on the basis of the anatomic section and physiological conditions, the possibility of assessing functional alterations is currently being studied. Indeed, a good correlation has been found between ADC values and glomerular filtration rate. With regard to musculoskeletal applications, the absence of motion artefacts in the regions studied has enabled the development of sequences less sensitive to magnetic susceptibility and with greater spatial resolution than EPI. Attempts have therefore been made to use Dw imaging in the characterization of soft-tissue tumours although the findings so far have been disputed. Greater agreement has been found regarding sensitivity of the technique in assessing response of these tumours to chemotherapy: tumour necrosis is thought to increase ADC whereas the persistence of vital neoplastic tissue tends to lower it. One of the most promising applications of Dw imaging is without doubt the assessment of vertebral collapse where a high ADC has been shown to be associated with an osteoporotic cause and a low ADC with a neoplastic cause. Nonetheless, even here, a moderate overlap between ADC values of the two types has been encountered. Dw imaging has also been used in the assessment of bone marrow cellularity: areas of tightly packed cells show a higher ADC value than hypocellular areas. In particular, no significant difference in ADC is noted between normal hypercellular bone marrow and hypercellular bone marrow secondary to lymphomatous infiltration whereas this difference is significant between hypocellular, normocellular and haematopoietic hypercellular bone marrow. With regard to the study of joints, the limited structure dimensions, particularly cartilage, creates technical difficulties related to spatial resolution and an adequate signal-to-noise ratio, problems that can only be solved by further technological developments. Lastly, a significant difference in ADC values between degenerative and inflammatory effusion has been found, a fact that may be explained as the result of the activity of hyaluronidase present in inflammatory forms, which causes a reduction in the concentration of hyaluronic acid with a consequent decrease in viscosity.

Abdomen↗

Analysis of different contrast enhancement patterns after microbubble-based contrast agent injection in liver hemangiomas with atypical appearance on baseline scan.

BACKGROUND: We describe different possible enhancement patterns in liver hemangiomas with atypical appearance on baseline ultrasound after microbubble-based contrast agent injection. METHODS: From a series of 253 consecutive lesions that were indeterminate on baseline ultrasound and then scanned after injection of air-filled microbubble contrast agent, 65 focal liver lesions were retrospectively selected on the basis of a diagnosis of liver hemangioma on multiphase contrast-enhanced computed tomography (n = 23), magnetic resonance imaging (n = 27), or histology (n = 15). Each lesion was scanned during arterial phase (30 s after microbubble injection) and late phase (5 min after injection). On-site sonologists performed retrospective assessment of contrast-enhancement patterns by consensus. RESULTS: Centripetal fill-in preceded (n = 50) or not preceded (n = 3) by peripheral nodular/rim-like enhancement was the prevalently observed contrast-enhancement pattern, equivalent to the typical enhancement pattern of liver hemangiomas on contrast-enhanced computed tomography or magnetic resonance imaging. In the remaining lesions, additional enhancement patterns (diffuse contrast enhancement with rapid fill-in and a late hyper-isoechoic appearance, n = 6; peripheral nodular enhancement with a late hypoechoic appearance, n = 3; or persistent heterogeneous and hyperechoic appearance, n = 3) were observed. CONCLUSION: Different contrast-enhancement patterns are possible in atypical liver hemangiomas after microbubble injection. Typical centripetal fill-in is the prevalent pattern and its evidence allows diagnosis.

Adult↗

Radiological evaluation of vaginal width and depth in male-to-female transsexuals by the use of magnetic resonance imaging.

Nowadays, the surgical treatment of male-to-female transsexuals is not rare, but few studies have reported on postoperative results. The aim of this study was to determine the role of magnetic resonance imaging (MRI) in the evaluation of the results of sex reassignment surgery (SRS) in male-to-female transsexual patients. Ten such patients (median age 28 years, range 21-47), who had undergone SRS using an inversion of combined penile and scrotal skin flaps for vaginoplasty, were examined with MRI after the operation. Turbo spin-echo T2-weighted and spin-echo T1-weighted images were obtained on sagittal, coronal, and axial planes with a 1.5 T superconducting magnet. The images were acquired on the sagittal, coronal and axial planes, by using TSE T2 weighted and SG T1 weighted images. MRI was performed within 2 weeks after the operation in six patients and after 1 year in the other four. In all cases, the images were obtained with and without an inflatable silicon vaginal tutor. The average neovaginal depth was 7.9 cm (range 6-10 cm). In four patients, MRI showed the presence of cavernosal rests, and in two there were remnants of the corpus spongiosus. In another patient, an abnormal anterior inclination of the neovagina was present. The average distance of the recto-vaginal septum was 4 mm (range 3-6 mm). No major complications were noted. Our study allowed not only a detailed assessment of the pelvic anatomy after genital reconfiguration, but also provided valuable information on possible complications.

Adult↗

Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results.

The purpose of this study was to evaluate the capability and the reliability of diffusion-weighted MRI in the evaluation of normal kidney and different renal lesions. 39 patients (10 normal volunteers and 29 patients with known renal lesions) underwent MRI of the kidneys by using a 1.5 T superconducting magnet. Axial fat suppressed turbo spin echo (TSE) T(2) and coronal fast field echo (FFE) T(1) or TSE T(1) weighted images were acquired for each patient. Diffusion-weighted (DW) images were obtained in the axial plane during breath-hold (17 s) with a spin-echo echo planar imaging (SE EPI) single shot sequence (repetition time (TR)=2883 ms, echo time (TE)=61 ms, flip angle=90 degrees ), with b value of 500 s mm(-2). 16 slices were produced with slice thickness of 7 mm and interslice gap of 1 mm. An apparent diffusion coefficient (ADC) map was obtained at each slice position. The ADC was measured in an approximately 1 cm region of interest (ROI) within the normal renal parenchyma, the detected renal lesions and the collecting system if dilated. ADC values in normal renal parenchyma ranged from 1.72 x 10(-3) mm(2) s(-1) to 2.65 x 10(-3) mm(2) s(-1), while ADC values in simple cysts (n=13) were higher (2.87 x 10(-3) mm(2) s(-1) to 4.00 x 10(-3) mm(2) s(-1)). In hydronephrotic kidneys (n=6) the ADC values of renal pelvis ranged from 3.39 x 10(-3) mm(2) s(-1) to 4.00 x 10(-3) mm(2) s(-1). In cases of pyonephrosis (n=3) ADC values of the renal pelvis were found to be lower than those of renal pelvis of hydronephrotic kidneys (0.77 x 10(-3) mm(2) s(-1) to 1.07 x 10(-3) mm(2) s(-1)). Solid benign and malignant renal tumours (n=7) showed ADC values ranging between 1.28 x 10(-3) mm(2) s(-1) and 1.83 x 10(-3) mm(2) s(-1). In conclusion diffusion-weighted MR imaging of the kidney seems to be a reliable way to differentiate normal renal parenchyma and different renal diseases. Clinical experience with this method is still preliminary and further studies are required.

Adult↗

Comparison between the efficacy of dimeric and monomeric non-ionic contrast media (iodixanol vs iopromide) in urography in patients with macroscopic haematuria.

Non-ionic dimers induce less diuresis than non-ionic monomers, resulting in increased opacification of the urinary tract in intravenous urography. This trial compared the diagnostic efficacy of iodixanol and iopromide in patients with macroscopic haematuria. One hundred consecutive patients with normal renal function and macroscopic haematuria entered a double blind, comparative, randomised, parallel trial. Contrast media were given with bolus injection in doses of 300 mgI/kg b.w. Radiographs were blindly evaluated by three radiologists who analysed different parameters (calyceal density and filling, papillary blush detection, delineation of collecting ducts, renal pelvis opacification, visualisation of ureters, bladder density, bladder distention) and estimated the diagnostic confidence (whether abnormal findings were definitely absent, probably absent, doubtful, probably present or certainly present). Radiological diagnoses were compared with final diagnoses. Results were summarised as the ratio of the odds of having a worse performance of iopromide vs iodixanol. Iodixanol showed a significantly better calyceal density and filling [odds ratio (OR): 1.96; 95% confidence interval (CI): 1.60-2.41], a significantly better pelvis opacification (OR 2.91; CI 2.02-4.18) and a significantly more frequent papillary blush detection (OR 1.95; CI 1.29-2.95). Iopromide showed a significantly better ureteral visualisation (OR 0.67; CI 0.48-0.92) and a significantly higher bladder distention (OR 0.59; CI 0.36-0.99). Iodixanol allowed a significantly higher diagnostic confidence as to calyceal evaluation (OR 1.35; CI 1.01-1.79). No significant differences were found with regard to other parameters. The results confirmed theoretical expectations. The higher opacification provided by iodixanol allowed better results and a higher diagnostic confidence in the upper excretory pathway.

Contrast Media↗

[Magnetic resonance (MR) in endometrial carcinoma preoperative evaluation].

BACKGROUND: Myometrial invasion of endometrial carcinoma is an important prognostic factor because the degree of myometrial invasion is correlated with the rate of lymphnode metastases and of recurrences. The aim of the study was a preoperative evaluation of endometrial carcinoma by Magnetic Resonance (MR). METHODS: The authors present a prospective study performed on 54 cases of endometrial carcinoma collected at the Department of Gynecology and Obstetrics of the University of Trieste (Italy). All the patients were considered as Stage I after hysteroscopy and endocervical curettage. Prior to surgery all the patients underwent MR at the Department of Radiology of the University of Trieste (Italy) in order to evaluate the depth of myometrial invasion. The surgical procedure included total abdominal hysterectomy, bilateral salpingo-oophorectomy and pelvic and lomboaortic lymphadenectomy in high risk cases. Statistical evaluation was performed by Fischer's exact test. RESULTS: Statistically significant positive correlation was found (p<0.001) between MR staging and surgical staging. The sensitivity reported in our series for distinguishing between superficial disease (Stage IA and IB) and deep myometrial invasion (Stage IC) was 92%. CONCLUSIONS: Preoperative MR is helpful in selecting patients at high risk of nodal involvement and it is suggested that, although MR is considered an expensive examination, its use should be always considered before surgical treatment of patients with high surgical risk.

Aged↗

Short-TE projection reconstruction MR microscopy in the evaluation of articular cartilage thickness.

The aim of this study was to assess the potential of projection-reconstruction (PR) MR microscopy in the accurate measurement of cartilage thickness. Short-TE PR microimages were acquired at 7.05 T on bone-cartilage cylindrical plugs excised from four regions of two disarticulated femoral heads (i. e. superior, inferior, posterior and anterior), using an NMR instrument equipped with a microimaging accessory. The PR microimages were then correlated with conventional spin-echo (SE) microimages and with histology. On PR microimages, acquired with an echo time of 3.2 ms, the cartilage signal was increased, allowing an accurate delineation of the cartilage from the tidemark/cortical bone region. As a consequence, by the PR method a more precise measurement of cartilage thickness compared with that performed by the conventional SE approach was feasible. An excellent correlation between PR microimages and histology was also obtained (r = 0.90). By the proposed method it is possible to accurately determine the cartilage thickness better than with the conventional SE sequences.

Aged↗

Dynamic magnetic resonance imaging in the assessment of chronic medical nephropathies with impaired renal function.

We examined the value of dynamic magnetic resonance imaging (MRI) in chronic renal disease with renal insufficiency. In 33 consecutive patients (21 vascular nephropathy, 12 glomerular nephropathy) MRI was performed using a 1.5-T unit and a body coil, with SE T1-weighted (TR/TE = 600/19 ms) and dynamic TFFE T1-weighted sequences (TR/TE = 12/5 ms, flip angle = 25 degrees ) after manual bolus injection (via a cubital vein) of 0.1 mmol/kg Gd-DTPA-BMA. Morphological evaluation was performed in unblinded fashion by three radiologists, evaluating renal size, cortical thickness, and corticomedullary differentiation. Functional analysis was performed by one reviewer. Time-signal intensity curves, peak intensity value (P), time to peak intensity (T), and the P/T ratio were obtained at the cortex, medulla, and pyelocaliceal system of each kidney. The relationship of these parameters to serum creatinine and with creatinine clearance was investigated. A good correlation between morphological features of the kidneys and serum creatinine values was found. Morphological findings could not distinguish between vascular and glomerular nephropathies. A statistically significant correlation (P <0.01) between cortical P, cortical P/T, medullary P, and serum creatinine and creatinine clearance was found. A significant correlation (P <0.01) was also found between cortical T, medullary P/T, T of the excretory system, and creatinine clearance. The cortical T value was significantly higher (P <0.01) in vascular nephropathy than in glomerular nephropathy. Thus in patients with chronic renal failure dynamic MRI shows both morphological and functional changes. Morphological changes are correlated with the degree of renal insufficiency and not with the type of nephropathy; the functional changes seem to differ in vascular from glomerular nephropathies.

Aged↗

Effects of a dimeric vs a monomeric nonionic contrast medium on renal function in patients with mild to moderate renal insufficiency: a double-blind, randomized clinical trial.

The efficacy and safety of nonionic dimeric contrast media in subjects with impaired renal function is largely unknown. The present study was aimed at determining the risk of tubular nephrotoxicity in patients with mild to moderate renal insufficiency who underwent intravenous urography (IVU) with the nonionic dimeric contrast agent iodixanol (Visipaque, Nycomed Imaging, Oslo, Norway). In a double-blind protocol 64 patients (55 males; mean age 68.3 years) with serum creatinine between 135 and 265 micromol/l who were to undergo IVU were randomized to receive iodixanol (a nonionic dimer) or iopromide (a nonionic monomer), 600 mg I/kg b. w. Renal function was evaluated before and 1 h, 6 h, 24 h, 48 h and 7 days after IVU with analysis of serum creatinine, urinary enzymes alanylaminopeptidase and N-acetyl-beta-glucosaminidase, and urinary microproteins alpha-1-microglobulin and albumin. Renal function remained stable in both contrast medium groups during the follow-up period. No statistically significant differences were observed between the monomer and the dimer in terms of urinary enzyme and microprotein excretion or serum creatinine. Transient radiocontrast-induced nephropathy developed in 1 patient who had received iodixanol. The administration of the nonionic dimeric contrast medium iodixanol, or of the nonionic monomer iopromide, entailed a low nephrotoxic potential in patients with mild to moderate renal insufficiency undergoing excretory urography.

Acetylglucosaminidase↗

Magnetic resonance imaging of articular cartilage: ex vivo study on normal cartilage correlated with magnetic resonance microscopy.

The aims of this study were (a) to compare the MR appearance of normal articular cartilage in ex vivo MR imaging (MRI) and MR microscopy (MRM) images of disarticulated human femoral heads, (b) to evaluate by MRM the topographic variations in articular cartilage of disarticulated human femoral heads, and subsequently, (c) to compare MRM images with histology. Ten disarticulated femoral heads were examined. Magnetic resonance images were obtained using spin-echo (SE) and gradient-echo (GE) sequences. Microimages were acquired on cartilage-bone cylindrical plugs excised from four regions (superior, inferior, anterior, posterior) of one femoral head, using a modified SE sequence. Both MRI and MRM images were obtained before and after a 90 degrees rotation of the specimen, around the axis perpendicular to the examined cartilage surface. Finally, MRM images were correlated with histology. A trilaminar appearance of articular cartilage was observed with MRI and with a greater detail with MRM. A good correlation between MRI and MRM features was demonstrated. Both MRI and MRM showed a loss of the trilaminar cartilage appearance after specimen rotation, with greater evidence on MRM images. Cartilage excised from the four regions of the femoral head showed a different thickness, being thickest in the samples excised from the superior site. The MRM technique confirms the trilaminar MRI appearance of human articular cartilage, showing good correlation with histology. The loss of the trilaminar appearance of articular cartilage induced by specimen rotation suggests that this feature is partially related to the collagen-fiber orientation within the different layers. The MRM technique also shows topographic variations in thickness of human articular cartilage.

Aged↗

Comparison between the efficacy of dimeric and monomeric non-ionic contrast media (iodixanol vs iopromide) in urography in patients with mild to moderate renal insufficiency.

Non-ionic dimers induce less diuresis than non-ionic monomers, resulting in increased opacification of the urinary tract in intravenous (i.v.) urography. This double blind, comparative, randomized, parallel trial compared the efficacy of iodixanol (non-ionic dimer) and iopromide (non-ionic monomer) in 100 patients with mild to moderate renal insufficiency (serum creatinine of 135 to 265 mumol l-1) who underwent i.v. urography. A total dose of 600 mgI kg-1 bw of iodixanol (320 mgI ml-1) or iopromide (300 mgI ml-1) was injected. Radiographs were blindly evaluated by three radiologists who analysed different parameters (renal border visualization, nephrogram density, calyceal filling and density, papillary blush detection, delineation of collecting ducts, renal pelvis opacification, visualization of ureters, bladder density, bladder distention). Densitometric evaluation on the renal pelvis and bladder was also performed. Iodixanol showed better filling and density of the calyces (p = 0.004), more frequent detection of papillary blush (p = 0.003) and better opacification of the renal pelvis (p = 0.006). No significant differences between the two contrast media were found in regard to other parameters. In conclusion, the results confirmed theoretical expectations. The non-ionic dimer iodixanol is to be preferred to a non-ionic monomer such as iopromide in i.v. urography on patients with impaired renal function.

Adult↗

Preliminary evaluation of an electromagnetic three-dimensional digitizer in facial anthropometry.

OBJECTIVE: In this investigation, the precision of a commercial three-dimensional digitizer in the detection of facial landmarks in human adults was assessed. METHODS: Fifty landmarks were identified and marked on the faces of five men, on five women, and on a stone cast of the face of one man. For each subject, the three-dimensional coordinates of the landmarks were obtained twice using an electromagnetic three-dimensional digitizer, and the duplicate digitizations were superimposed using common orientations and centers of gravity. Metric differences between homologous landmarks were assessed, and Dahlberg's error was computed. RESULTS: For both men and women, the error was 1.05% of the nasion-midtragion distance, while for the cast, it was 0.9%. When the duplicate digitizations were used to mathematically reconstruct the faces, and several distances, angles, volumes, and surfaces were computed, more than 80% of the measurements had coefficients of variation lower than 1%. CONCLUSIONS: The digitizer can assess the coordinates of facial landmarks with sufficient precision, and reliable measurements can be obtained.

Adult↗

Effect of growth and development on cephalometric shapes in orthodontic patients: a Fourier analysis.

The age- and gender-related shape variations of the craniofacial skeleton in skeletal Class I children were quantified using a Fourier analysis on the pre-treatment lateral head films of 122 orthodontic patients (age range 7-15 years), who were subdivided into six groups for sex and age (2-year intervals). Seven landmarks representative of the maxillo-mandibular sagittal and vertical relationship were identified and digitized. The contiguous landmarks were connected by segments, the form was normalized with respect to its orientation and size, and a Fourier analysis of the contour was performed. Mean values of the cosine and sine coefficients of the first six harmonics in the sex and age classes were computed. The size-standardized outlines of the oldest boys were narrower and longer than the outlines of the youngest boys (differences at gonion, menton, sella and nasion). Shape differences between mean plots in girls were negligible. In the youngest patients, girls had a larger size-independent shape in the mandibular region; their shape was narrower (anterior-posterior direction) and longer (vertical direction) than male shape. In the oldest patients, boys had a larger size-independent shape at gonion, and a narrower shape at articulare and pogonion than girls. Size increased from the youngest to the oldest boys; size differences were not conspicuous in girls. Within an age class, male size was always larger than female. Fourier analysis allowed a global evaluation of the cephalometric forms, with separate quantifications of the age- and gender-related differences in size and shape.

Adolescent↗

MRI appearance of the articular cartilage in the knee according to age.

To study the MR appearance of knee joint hyaline cartilage according to age, sex and body weight 120 subjects underwent MRI of the knee. Axial SE PD and T2, GE T1 and GE-MTC sequences, as well as coronal SE T1 and sagittal SE PD and T2 sequences were used. Thickness, surface, signal intensity and visibility of the patellar and femorotibial cartilages were investigated. As for cartilage thickness, a statistically significant difference was found between males and females in nearly all the measurement sites, the mean values being always higher in males. A statistically significant inverse correlation was found in males only, at the three load bearing regions of the medial femoral condyle. No significant correlation was demonstrated between the surface, the signal intensity and the trilaminar appearance of the cartilage and age, as well as body weight. The cartilage of the femoral condyles, the tibial plateaux and the patella showed a regular surface in 76%, 98% and 82% of cases respectively. The signal intensity was homogeneous in 88%, 98% and 82.5% of the cases. Mild focal inhomogeneities were seen in few cases. The visibility rate of the trilaminar appearance of cartilage was 85% for the femoral condyles, 70% for the patella, 13.5% for the tibial plateaux. GE sequence was the best sequence to evaluate cartilage thickness and signal intensity, while SE T2 sequence was the best sequence to depict the articular surface and, together with PD SE sequence, to visualize the trilaminar structure. The most relevant result of this study is the inverse correlation between cartilage thickness and age as well as body weight, mainly in males, in the three areas of greatest load (medial femoral condyle).

Adolescent↗

[Comparison of magnetic resonance Spin-echo sequences and fat-suppressed sequences in bone diseases].

Thirty-two patients affected with skeletal conditions were examined with MRI using Short TI Inversion Recovery sequence and Spectral Presaturation with Inversion Recovery (SPIR) sequence as well as Spin-Echo (SE) T1-weighted sequence and Fast Spin-Echo (FSE) T2-weighted sequence to compare their value in the assessment of skeletal lesions. SPIR sequence was performed after intravenous injection of Gd-DTPA. The lesions included primary bone tumors (10 cases: 1 osteosarcoma, 1 periosteal sarcoma, 1 Ewing's sarcoma, 1 chondrosarcoma, 2 non-ossifying fibromas, 1 chondroma, 1 chondromyxoid fibroma, 1 desmoplastic fibroma and 1 bone cyst), metastases (7 cases: 3 prostate, 3 breast, 1 lung-squamous cell carcinoma), infections (12 cases: 9 osteomyelitis, 3 spondylodiscitis), sacroiliitis (1 case) and posttraumatic bone bruise (2 cases of bone marrow edema). The four sequences were compared by using both qualitative and quantitative evaluation. Qualitative evaluation showed that STIR sequence was better than SPIR sequence (performed with Gd-DTPA) for lesion conspicuity (p < .016) and for signal intensity uniformity (p < .03). Compared with SE T1 and FSE T2 sequences, fat-suppressed sequences were superior for conspicuity, margins, and extension of the lesions (range of p < .001-.017). Only SPIR with Gd-DTPA sequence, compared with SE T1 sequence for lesion conspicuity was not statistically significantly different. Quantitative evaluation showed statistically significant higher values of percent contrast (%C) and contrast-to-noise ratio (C/N) for STIR sequence compared with SPIR sequence (%C p < .004; C/N p < .040). This study suggests that STIR sequence and SE T1-weighted sequence provide high sensitivity in lesion detection and good anatomical definition. The use of a fat-suppressed sequence with Gd-DTPA can be useful for lesion characterization.

Adolescent↗

[A comparison between an ionic paramagnetic contrast agent (Gd-DTPA) and a nonionic one (Gd-DTPA-BMA) in functional kidney evaluation with magnetic resonance].

INTRODUCTION: The combination of TGE sequences with bolus injection of paramagnetic contrast agents permits to study renal function and perfusion. We studied renal function with both an ionic (Gd-DTPA) and a nonionic paramagnetic contrast agent (Gd-DTPA-BMA) to compare their kinetics in normal kidneys. MATERIAL AND METHODS: Twenty MR examinations were performed on 20 subjects with normal renal function. Ten subjects were examined after i.v. injection of Gd-DTPA and the other ten subjects after i.v. injection of Gd-DTPA-BMA. MR examinations were performed on a Philips ACS II unit (1.5 T). Two sequences were acquired in all cases; an SE coronal T1-weighted sequence (TR/TE = 600/19 ms) and a TGE coronal T1-weighted sequence (TR/TE = 12/5 ms, flip angle = 25 degrees) performed after bolus injection of the contrast agent at 0.1 mmol/kg. Signal intensity time curves were obtained in all the cases. The signal intensity of the cortex, corticomedullary junction, medulla and the pyelocaliceal system of each kidney was measured using a region of interest (ROI). Signal intensity curves were analyzed considering some quantitative parameters such as the area under the curve (AUC), the peak (P) and the time to peak (T-P). RESULTS: In the subjects with normal renal function, four phases were demonstrated after the i.v. injection of either Gd-DTPA or Gd-DTPA-BMA, namely the cortical phase, the cortico-medullary junction phase, the medullary phase and the pyelocaliceal system phase. No statistically significant differences between the two agents were demonstrated in signal intensity time curves and quantitative parameters. CONCLUSIONS: Gd-DTPA and Gd-DTPA-BMA showed the same efficacy in renal function studies.

Analysis of Variance↗

[Virtual endoscopy with computed tomography of the anatomical structures of the middle ear].

INTRODUCTION: We applied the new technique of virtual endoscopy to the middle ear because this anatomical area is characterized by favorable contrast. MATERIALS AND METHODS: CT examinations of the petrous bone were obtained using 1.5 mm thick 1 coronal axis slices, with 1 mm or 1.5 mm table feed, 120 kV, 140-170 mA and 2 s scan time. The images were reconstructed with the high resolution algorithm for bony structures and a small field of view (9.6 cm), separately for the right and left petrous bone. The images were then transferred on a workstation and processed with the Navigator virtual endoscopic software (General Electric). A threshold value ranging -350 to -600 HU was applied. RESULTS: A series of images is acquired as the virtual endoscope moves from the external auditory canal to the middle ear cavity. Images of the anterior, medial, and posterior surfaces of the middle ear are presented. Different views of the ossicles are also presented. High quality images were always obtained for the middle ear structures, including the ossicles. CT endoscopy of the middle ear provides a new view of the anatomy of this complex area. It has some advantages and disadvantages; the former can be summarized as follows: -demonstration of areas which are difficult to show with endoscopy because of the presence of membrana tympani; -the virtual endoscope can be placed in several positions and therefore it can be inserted in all sites and tortuous places of anatomical cavity; -nice and effective demonstration of the ossicular chain including the stapes. The disadvantages are related to the fact that the endoscopic reconstruction (such as any other three-dimensional reconstruction) is a representation of surfaces where different densities are necessarily homogenized. CONCLUSIONS: CT virtual endoscopy of the middle ear can currently be considered a complementary technique to conventional CT because it permits better anatomical detailing of this complex region.

Ear, Middle↗