PubMed Health⌕ Search

Biomedical subjects

M Cronin

Publications and source records attributed to M Cronin.

At least 37 records · Page 2Linked to original sources

Comparison of two amplification technologies for detection and quantitation of human immunodeficiency virus type 1 RNA in the female genital tract. Division of AIDS Treatment Research Initiative 009 Study Team.

Human immunodeficiency virus type 1 (HIV-1) RNA levels in female genital tract and peripheral blood samples were compared using two commercial amplification technologies: the Roche AMPLICOR HIV-1 MONITOR test and either the Organon Teknika nucleic acid sequence-based amplification (NASBA-QT) assay or the NucliSens assay. Estimates of HIV-1 RNA copy number were derived from internal kit standards and analyzed unadjusted and adjusted to a common set of external standards. We found a discordance rate of approximately 18% between the two technologies for the detection of HIV-1 in either the genital tract or peripheral blood samples. Detection discordance was not consistent among specimens or among women. There were no significant differences in adjusted or unadjusted estimates of HIV-1 RNA copy number in the genital tract samples using the AMPLICOR HIV-1 MONITOR test and either the NASBA-QT assay or the NucliSens assay. In addition, the estimated HIV-1 RNA copy number in peripheral blood samples did not differ when tested with the NucliSens assay and the AMPLICOR HIV-1 MONITOR test using kit standards. However, there was a significant difference in estimated RNA copy number between the NASBA-QT assay and the AMPLICOR HIV-1 MONITOR test for internal kit standards, which, as we have previously shown, was eliminated after adjustment with the external standards. Our results suggest that the Roche and Organon Teknika assays are equivalent for quantifying HIV-1 RNA in female genital tract specimens, although variation in detection does exist.

Cross-Sectional Studies↗

Pharmacogenomics: the promise of personalized medicine.

Pharmacogenetics and pharmacogenomics deal with the genetic basis underlying variable drug response in individual patients. The traditional pharmacogenetic approach relies on studying sequence variations in candidate genes suspected of affecting drug response. On the other hand, pharmacogenomic studies encompass the sum of all genes, i.e., the genome. Numerous genes may play a role in drug response and toxicity, introducing a daunting level of complexity into the search for candidate genes. The high speed and specificity associated with newly emerging genomic technologies enable the search for relevant genes and their variants to include the entire genome. These new technologies have essentially spawned a new discipline, termed pharmacogenomics, which seeks to identify the variant genes affecting the response to drugs in individual patients. Moreover, pharmacogenomic analysis can identify disease susceptibility genes representing potential new drug targets. All of this will lead to novel approaches in drug discovery, an individualized application of drug therapy, and new insights into disease prevention. Current concepts in drug therapy often attempt treatment of large patient populations as groups, irrespective of the potential for individual, genetically-based differences in drug response. In contrast, pharmacogenomics may help focus effective therapy on smaller patient subpopulations which although demonstrating the same disease phenotype are characterized by distinct genetic profiles. Whether and to what extent this individual, genetics-based approach to medicine results in improved, economically feasible therapy remain to be seen. To exploit these opportunities in genetic medicine, novel technologies will be needed, legal and ethical questions must be clarified, health care professionals must be educated, and the public must be informed about the implications of genetic testing in drug therapy and disease management.

Animals↗

Absolute copy number and relative change in determinations of human immunodeficiency virus type 1 RNA in plasma: effect of an external standard on kit comparisons.

Use of a common set of human immunodeficiency virus type 1 (HIV-1) RNA standards eliminated differences among absolute HIV-1 RNA copy number estimates made with three commercially available assays. The relative changes in the viral RNA levels determined by the commercial assays were similar and were unaffected by the use of a common set of standards.

Female↗

A 3-month clinical investigation comparing the safety and efficacy of a novel electric toothbrush (Braun Oral-B 3D Plaque Remover) with a manual toothbrush.

PURPOSE: To compare the efficacy and safety of a novel electric toothbrush (Braun Oral-B 3D Plaque Remover) with a standard reference ADA manual toothbrush. MATERIALS AND METHODS: 114 subjects were included in a 3-month randomized, parallel group, examiner-blind study and divided into two groups: 3D users and manual toothbrush users. Subjects were instructed to brush twice daily for 2 minutes. Evaluation of oral soft and hard tissue for safety, plaque, gingivitis and bleeding was conducted prior to the start of product use (at baseline), at days 14 and 35, and at 3 months. RESULTS: 105 subjects (55 3D users and 50 manual toothbrush users) completed the study. At days 14, 35 and at 3 months both groups showed reductions from baseline in whole mouth plaque, gingivitis and bleeding that were statistically significant (P < 0.005), except in the case of plaque at day 35 in manual toothbrush users. At 3 months, reductions for whole mouth plaque, gingivitis and bleeding were 15%, 16% and 65%, for 3D users and 8%, 12% and 56%, for manual toothbrush users, respectively. Group differences were significant (P < 0.05) in favor of the 3D with respect to plaque reduction for the whole mouth and for interproximal and anterior lingual sites at all three time periods. With respect to gingivitis, reductions for the whole mouth and interproximal and posterior lingual sites at 3 months were significantly greater in the 3D group. There was no clinically significant soft or hard tissue abrasion in either group. In conclusion, the 3D electric toothbrush was found to be safe and had increased efficacy with respect to reduction of plaque and gingivitis compared to a manual toothbrush.

Adolescent↗

Effects of specimen collection, processing, and storage conditions on stability of human immunodeficiency virus type 1 RNA levels in plasma.

To define the optimal blood collection parameters for plasma human immunodeficiency virus type 1 (HIV-1) viral load testing, plasma HIV-1 RNA levels were quantitated with the NASBA HIV-1 RNA QT System from blood specimens that were collected, processed, and stored under a variety of conditions that might have affected HIV-1 RNA stability. We determined that when whole blood was processed within 2 h of specimen collection the levels of HIV-1 RNA detected in EDTA-, heparin-, and acid citrate dextrose (ACD)-anticoagulated plasma samples were comparable. The levels of HIV-1 RNA in serum specimens (mean = 4.126 log units) were significantly lower (P < 0.01) than the levels in corresponding plasma samples (mean = 4.501 log units). One cycle of freeze-thaw (-70 degrees C) did not significantly reduce the level of HIV-1 RNA detected in EDTA-, heparin-, or ACD-anticoagulated plasmas. The EDTA-anticoagulated plasmas showed the smallest decrease in HIV-1 RNA copies (0.050 log units). HIV-1 RNA levels decreased over a 6-month time period in serum as well as in EDTA-, ACD-, and heparin-anticoagulated plasmas stored at -70 degrees C. However, the only significant decreases were for serum (mean decrease = 0.317 log units) and heparin-anticoagulated samples (mean decrease = 0.384 log units). A comparison of the levels of HIV-1 RNA in cell-free plasma collected in VACUTAINER EDTA Plasma Preparation Tubes and in standard VACUTAINER EDTA tubes determined that HIV-1 RNA levels were stable for up to 30 h after collection when stored at either room temperature (mean standard deviation [SD] = +/- 0.101 log units) or at 4 degrees C (mean SD = +/- 0.102 log units) as cell-free plasma or as EDTA-anticoagulated whole blood (mean SD = +/- 0.109 log units). These data indicate that EDTA-anticoagulated plasma is the most suitable and stable matrix for HIV-1 RNA quantitation.

Anticoagulants↗

High viral load in semen of human immunodeficiency virus type 1-infected men at all stages of disease and its reduction by therapy with protease and nonnucleoside reverse transcriptase inhibitors.

Seminal viral load is likely to be directly related to the sexual transmissibility of human immunodeficiency virus type 1 (HIV-1). However, it is not clear whether the level of HIV-1 in semen varies with the stage of infection and whether antiretroviral therapy reduces seminal viral load. A nucleic acid sequence-based amplification (NASBA) technique was used to quantify HIV-1 RNA as an indicator of infectious viral load in semen and blood plasma of homosexual men with different stages and durations of HIV-1 infection. The median viral load in a cross section of 34 men was 11,000 HIV-1 RNA copies/ml (range, <400 to 1.3 x 10(7) copies/ml) in whole semen and 5,238 HIV-1 RNA copies/ml (range, <400 to 2.8 x 10(5) copies/ml) in seminal plasma, which is 10- to 1,000-fold higher than previous estimates. Viral loads in whole semen and seminal plasma were strongly correlated with blood plasma viral load (P < 0.001) but not with blood CD4+ T-cell count (P = 0.420). Longitudinal analysis of eight subjects who progressed to AIDS showed that seminal viral load increased in most cases, with viral load consistently higher in blood plasma than in semen. Viral loads in semen and blood plasma decreased markedly in six other patients following initiation of potent combination therapy with a protease inhibitor (indinavir) and a nonnucleoside reverse transcriptase inhibitor (DMP-266). These findings have important implications for the biology of sexual transmission of HIV-1 and its potential reduction by antiretroviral therapy.

Acquired Immunodeficiency Syndrome↗

The safety and efficacy of gingival massage with an electric interdental cleaning device.

The safety and efficacy of an interdental cleaning device (Braun Oral-B Interclean--ID2) used with a Flexi-Tip gingival massage attachment were evaluated in an investigator-blind comparison with manual floss. Over a 4-week period, 59 healthy volunteers were studied with respect to whole-mouth and interproximal plaque accumulation, gingival index and gingival bleeding. Eligible subjects were randomly assigned to one of the two experimental groups following a complete dental examination on Day 1. Subjects each underwent a dental prophylaxis before receiving flossing or massaging instructions. Plaque, gingivitis and gingival bleeding index scores were evaluated at Day 1 and Week 4. There was a significant reduction from baseline in all three parameters (whole-mouth and interproximal) in each of the groups, over the 4-week period. Reductions for whole-mouth and interproximal plaque scores were 20.3% and 17.0%, respectively in the ID2 group, compared with 16.2% and 13.8%, respectively in the manual floss group. Reductions for gingivitis were 13.0% and 14.1% in the ID2 group, compared with 14.0% and 16.2% in the manual floss group, and for gingival bleeding 52.2% and 53.6% in the ID2 group, compared with 51.7% and 55.6% in the manual floss group, respectively. Differences between treatment groups for each study parameter were not statistically significant. There was no significant soft tissue pathology noted in either study group. The results demonstrated that the manual floss and the interdental cleaning device, when used with the gingival massage attachment, were equally effective.

Adolescent↗

Long-acting growth hormones produced by conjugation with polyethylene glycol.

Derivatives of human growth hormone (hGH) of increasing size were produced by reaction with the N-hydroxysuccinimide ester of polyethylene glycol-5000 (PEG5000), a 5-kDa reagent that selectively conjugates to primary amines. By adjusting the reaction conditions and purification procedure, it was possible to isolate hGH derivatives containing up to seven PEG moieties that altered the Stokes radius and thereby the effective molecular masses of the unmodified hormone from 22 to 300 kDa. Fortunately, the most reactive amines were ones that did not lie in either of the two sites important for receptor binding. Nonetheless, increasing the level of PEG modification linearly reduced the affinity of hGH for its receptor and increased the EC50 in a cell-based assay up to 1500-fold. Most of the reduction in affinity was the result of slowing the association rate for the receptor. The clearance rate of hGH in rats was inversely proportional to effective molecular weight and closely fit a filtration model. We have tested the potency of these analogs by injecting them daily or every 6 days into hypophysectomized rats and determining the effects on body and organ growth. The efficacy of these analogs was optimal for hGH conjugated with 5 eq of PEG5000, and the potency was increased by about 10-fold compared with unmodified hGH. Such PEG-hGH derivatives show promise as long-acting alternatives to daily injections of hGH. More generally these studies show that improving hormone clearance properties, even at the expense of reducing receptor binding affinity, can lead to dramatic increases in hormone efficacy.

Animals↗

Evaluation of a quality assurance program for quantitation of human immunodeficiency virus type 1 RNA in plasma by the AIDS Clinical Trials Group virology laboratories.

A number of quantitative assays have been developed by using amplification techniques to measure human immunodeficiency virus type 1 RNA in the plasma of infected individuals. The Virology Committee of the AIDS Clinical Trials Group in the Division of AIDS, National Institute of Allergy and Infectious Diseases, has established a quality assurance program (QAP) for quantitative assays of HIV-1 RNA levels in plasma. The primary objective of the QAP was to ascertain that a laboratory could maintain the precision required to have a 90% power to detect a fivefold difference in RNA copy number between two samples in the same batch. To achieve this goal, the QAP required an intra-assay standard deviation of no greater than 0.15 log10 RNA copies per ml. Panels for proficiency testing consisted of coded replicate samples and a common set of standards. To date, 41 laboratories have participated in the program and have used both commercial and in-house assays. We demonstrated that 65% of the laboratories were capable of attaining the necessary level of intra-assay precision. The fitted regressions indicated that the differences among laboratories that used the same kit were generally greater than the differences among population-average regressions for the kits themselves. The use of an external QAP and a common set of standards reduced differences both among laboratories that used the same kit and among laboratories that used different kits. Thus, use of a common set of standards across clinical trial protocols would allow for cross-protocol comparisons.

Clinical Protocols↗

Cisplatin and emesis: aspects of treatment and a new trial for delayed emesis using oral dexamethasone plus ondansetron beginning at 16 hours after cisplatin.

The marked progress in controlling emesis caused by cisplatin characterizes the current status of antiemetic treatment for all chemotherapy. Cisplatin has provided a model for antiemetic studies. Strategies for controlling cisplatin-induced emesis are at least as successful when applied to other chemotherapy and persistent problems such as delayed emesis and the emesis associated with consecutive-day chemotherapy are also similar to or less severe than those observed with cisplatin. The purpose of this report is twofold: first to outline briefly therapy for cisplatin-induced emesis as illustrated by several new studies, and, second, to report on a new trial that incorporates some different strategies in the control of delayed emesis after cisplatin.

Administration, Oral↗

A comparative clinical study of extrinsic tooth stain removal with two electric toothbrushes [Braun D7 and D9] and a manual brush.

PURPOSE: To evaluate the efficacy and safety of two oscillating/rotating toothbrushes, (Braun Oral-B Plaque Remover-D7 and Braun Oral-B Ultra Plaque Remover-D9) and a manual toothbrush with respect to removing extrinsic dental stain. MATERIALS AND METHODS: This randomized, three-way cross-over study investigated 24 subjects entering the trial, which was divided into three, 5-day periods. Over the first 4 days of the study, an intense chlorhexidine/tea rinsing regimen was employed to induce extrinsic tooth staining. On day 5, each subject was assessed for tooth stain; they then brushed for a total of 2 minutes with one of the three randomly allocated toothbrushes. Stain evaluations were repeated after 30 seconds, 1 and 2 minutes brushing, with the intensity of stain, area of stain and number of sites with < 10% stained tooth area, being recorded at each assessment. RESULTS: Analysis of the results showed that the two electric toothbrushes were significantly better at removing stain than the manual toothbrush. In addition, the D9 was consistently more effective than the D7, with the difference with respect to stain area achieving statistical significance (P < 0.05) after 2 minute's brushing. All three brushes were found to be safe, and there was no evidence of any soft or hard tissue abrasion. It was concluded that the oscillating/rotating electric toothbrushes were more effective in removing extrinsic dental stain than a manual brush, and that compared with the D7, the newly designed Braun Oral-B Ultra Plaque Remover has an increased potential for stain removal.

Adolescent↗

An investigation of the efficacy and safety of a new electric interdental plaque remover for the reduction of interproximal plaque and gingivitis.

This clinical study was conducted to compare the efficacy and safety of the new Braun Oral-B Interclean (ID2) with that of dental floss in healthy adults. Volunteers with sufficient dental plaque and gingivitis were randomized to use the ID2 (n = 24) or American Dental Association-approved dental floss (n = 24) in conjunction with toothbrushing once nightly for 6 weeks. All subjects received a supragingival prophylaxis and polishing at the start of the study. Over the study period, both devices produced significant reductions in interproximal plaque, gingivitis and bleeding (p < 0.01). With the ID2, there were reductions in interproximal plaque scores (all sites) of approximately 40% compared with 28% with dental floss. A decrease in gingivitis of 15% was observed with the ID2 compared with 12% for floss users. Bleeding on probing was reduced by 25% with the ID2 and by 34% with dental floss. There was a trend in favor of the ID2 with respect to reduction in plaque which achieved statistical significance (p = 0.05) for the posterior three interproximal sites. Differences between treatment groups with respect to gingivitis and bleeding reductions were not statistically significant. No adverse events were reported or observed during the study. It is concluded that the ID2 has equivalent efficacy to dental floss for the reduction of interproximal plaque and gingivitis.

Adolescent↗

Transit through the distal quarter of the oesophagus in young children.

The transit time of 800 individual boluses through the distal quarter of the oesophagus was measured in 33 scintigraphic oesophageal studies which had been selected as typifying normal swallows in children. The results show that, in children, transit time through the distal quarter including the lower oesophageal sphincter is normally less than 2 seconds and that transit tends to be slower during the first 4 seconds after onset of swallowing.

Deglutition↗

Three clinical trials comparing xylitol- and sorbitol-containing chewing gums for their effect on supragingival plaque accumulation.

Studies have evaluated the effects of xylitol when administered in chewing gum, as a dietary substitute for sugar, in dentifrice and in mouthrinse. Three clinical trials were conducted to further investigate chewing gums containing xylitol or xylitol/sorbitol mixtures for their ability to reduce plaque accumulation when compared to a sorbitol containing gum. These studies all had two phases; supragingival prophylaxis with an assessment of plaque accumulation to be used for balanced assignment for the second phase, which assessed plaque regrowth following a second supragingival prophylaxis and various chewing gum regimens. In the first trial of xylitol/sorbitol versus sorbitol gum only, the combination gum had a significantly greater reduction in plaque growth. In the second trial, different regimens of chewing gums with xylitol/sorbitol and sorbitol alone were compared. The combined average of the plaque regrowth scores for the subjects chewing the xylitol/sorbitol gum was significantly better than that for the sorbitol gum alone. The final trial evaluated two regimens in two forms (stick and pellet) of a xylitol gum versus a sorbitol gum. Both xylitol-containing gum forms were statistically superior to the sorbitol gum in retarding plaque regrowth.

Adolescent↗