Chemometric approach to laser-induced breakdown analysis of gold alloys.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M D Luque de Castro.
Explore the source record for details and available documents.
The coupling of a static pressurized liquid extractor to a flow injection manifold has allowed real-time on-line fluorescence monitoring of the polycyclic aromatic hydrocarbons (PAHs) extracted from environmental solid samples, which can be used for either screening or semiquantitative purposes. Sodium dodecyl sulfate (SDS) was added to the water for favoring the extraction of the low-polar analytes. Different solid samples such as sandy soil, river sediments, trout and sardine spiked with the target PAHs were subjected to several 15-min static extraction cycles with SDS-water, at 200 degrees C. The results obtained demonstrated that fluorometric monitoring of static pressurized liquid extraction constitutes an approach as efficient as conventional Soxhlet for the extraction of PAHs from solid samples but with the following positive features: (a) drastic reduction of the extraction time as the extraction kinetics can be monitored and thus the end of the leaching step determined independently of the sample matrix; (b) use of water as extractant thus given place to an environmentally friendly method; and (c) coupling of static extraction to subsequent dynamic steps. The method has been applied to a certified reference material (CRM 524, BCR, industrial soil/organics) for quality assurance/validation. The total content of each analyte was determined by HPLC-fluorimetric detection.
A comparison of the feasibility of the three operational modes of pressurized hot solvent extraction (PHSE) (namely, static, where a fixed extractant volume is used; dynamic, where the extractant continually flows through the sample; and static-dynamic mode, which consists of a combination of the two previous modes) for the extraction of polycyclic aromatic hydrocarbons (PAHs) from environmental solid samples (such as soil, sediment, trout, and sardine) has been performed. In all cases, a sodium dodecyl sulfate (SDS) aqueous solution was used as leaching agent. The use of a flow injection manifold between the extractor and a molecular fluorescence detector allowed real-time on-line fluorescence monitoring of the PAHs extracted from the samples, thus working as a screening system and providing qualitative and semiquantitative information on the target analytes extracted from both natural and spiked samples. The on-line monitoring option allowed the extraction kinetics to be monitored and the end of the leaching step to be determined independently of the sample matrix, thereby reducing extraction times. Efficiencies close to 100% have been provided by the three modes, which differ in the extraction time required for total removal of the target compounds. The time needed for the dynamic mode was shorter than that for the static mode. However, the establishment of a static extraction step prior to dynamic extraction was the key to shorten the time required for complete extraction. The method has been applied to a certified reference material (CRM 524, BCR, industrial soil/organics) for quality assurance/validation.
Subcritical water extraction has been coupled with filtration, preconcentration and chromatographic analysis for the determination of acid herbicides in different types of soil. Two experimental designs were used for the optimization of the leaching step. The use of water as extractant in the continuous mode at a flow-rate of 1 ml/min and 85 degrees C was sufficient for quantitative extraction of the analytes. A static extraction time was unnecessary for reducing the extraction time to 1 h. A minicolumn containing C18-Hydra as sorbent proved an excellent material for the quantitative preconcentration of the herbicides prior to individual chromatographic separation. A flow-injection manifold was used as interface for coupling the four steps, thus allowing automation of the whole analytical process. Recoveries of the target analytes ranged between 94.2 and 113.1%, and repeatabilities, expressed as relative standard deviations, were between 0.61 and 6.83%.
A flow injection method for the determination of readily assimilable nitrogen (r.a.n.), i.e. ammonium and aminated nitrogen, is reported. The difference in pH of the sample in the presence and absence of formaldehyde, which blocks the amino function, provides the value of r.a.n. by monitoring the changes in absorbance of bromothymol blue at 616 nm. The detection and quantification limits are 10 and 11.6 mg l(-1), respectively, the reproducibility and repeatability are 3.94 and 1.35 mg l(-1), respectively, and the sample throughput is 20 samples h(-1). The method has been applied to the analysis of 120 samples of must and wine subjected to biological aging. The proposed method also provides good correlation with the reference method used in routine analysis, and is faster
A continuous ultrasound-assisted extractor was coupled to a photometric detector in order to obtain a fully automated approach for the determination of CrVI in soil. The use of a flow injection (FI) manifold as interface between the extractor and the photometric detector allowed the monitoring of CrVI after extraction in a continuous manner. The coloured complex formed between 1,5-diphenylcarbazide (DPC) and CrVI was used as recommended in EPA method 7196A because it is one of the most sensitive and selective reactions for CrVI determination. A preconcentration minicolumn packed with a strong anion-exchange resin was placed between the extractor and the detector, providing a more sensitive method. The linear dynamic ranges were 1-10 and 0.25-7.5 mg l-1 for the methods without (method A) and with preconcentration (method B), respectively. The limits of detection were 4.52 ng for method A and 1.23 ng for method B. Both methods were applied to a natural contaminated soil and the results obtained agreed well with those obtained by the reference EPA method 3060A. The influence of different amounts of CrIII in the samples was also studied and the results showed that the proposed methods did not disturb the original species distribution.
A prototype of a Soxhlet extractor that enables the use of water as extractant and application of focused microwaves on the cartridge zone has been designed and checked. The approach consists of a single unit in which the shortening of the distillation glassware allows reception of the water vapor in a refrigerant connected to the top of the sample cartridge vessel, its condensation, and dropping on the solid sample. When the water into the cartridge has reached a given level, irradiation with focused microwaves during an optimized time accelerates the leaching of the target analytes. Then, a valve is actuated and the extract is driven to the distillation flask where the leached species are concentrated as new vapor is formed and sent to the refrigerant and then to the cartridge. This new hybrid discontinuous-continuous approach has been used for leaching acid herbicides from different types of soil. The time required for total removal of the target compounds was 48 min. A flow injection manifold made posible the integration of the subsequent steps (preconcentration, chromatographic separation, UV detection) for the determination of the analytes, the recoveries of which range from 105.24 to 96.44%.
An overview of the different extraction procedures of fat-soluble vitamins from human fluids, foods and pharmaceutical preparations is presented. Methods using organic solvent extraction (both liquid-liquid and solid-liquid extraction), supercritical fluid extraction and solid-phase extraction for the different types of both vitamins and matrices are discussed.
A continuous method, easy to automate, for the determination of anthocyanins in wine based on the coupling of continuous liquid-solid extraction, evaporation, HPLC individual separation and photometric detection is proposed. The target analytes are removed from the wine in a continuous fashion using a C18 minicolumn and eluted with an aqueous solution (pH 2) with 16% acetonitrile. The eluted fraction is concentrated by solvent evaporation assisted by heat and dragging off the vapour using a flow of N2. For in-line preconcentration, a continuous evaporation module was designed and located in the manifold between the solid-phase minicolumn and the injection valve of the chromatograph. In this way, injection of the sample into the dynamic system leads the plug through it for liquid-solid extraction of the anthocyanins, partial evaporation of the eluent (with a preconcentration factor as required) and transport to the high-pressure injection valve of the chromatograph, where individual separation and subsequent photometric detection take place. The method thus developed for the determination of malvidin-3-glucoside, cyanidin-3-glucoside and peonidin-3-glucoside anthocyanins in Spanish red wines is more sensitive than the batch manual method based on the same steps, has better linearity of the calibrations curves with lower detection limits and much wider determination range for the most abundant anthocyanins in wine. In addition, the method can be fully automated with low acquisition and maintenance costs.
A flow injection fluorimetric method is proposed for the determination of chloroquine based on the photochemical derivatisation in an alkaline medium of the analyte and fluorescence generation after irradiation with a pulsed Nd:YAG laser operated at 355 nm. Chemical, hydrodynamic and laser variables were studied in order to obtain the best conditions for quantification. A linear range from 25 to 600 micrograms/L was achieved, with a correlation coefficient of 0.997 (n = 8), an RSD of 4.3% (n = 11) and a detection limit of 8 micrograms/L (3 sigma). The sample throughput was 10 h-1. The method was successfully applied to the determination of chloroquine in human plasma. The increase of sensitivity with respect to the method based on monitoring the intrinsic fluorescence of chloroquine itself was 1.7 times.
A novel dynamic nonequilibrium technique for the determination of Henry's law constant (HLC) of phenols based on pervaporation-flow injection (PFI) is described. A linear relationship between HLC and the amount of phenol measured by a detector in the acceptor line of a PFI system was demonstrated. This relationship was constructed using five frequently encountered phenols (phenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 2-chlorophenol, and 2,3-dimethylphenol) and used for the determination of the HLC of three other phenols (2,4,6-trichlorophenol, 2-methylphenol, and 3-methylphenol). The HLC of all eight phenols were also determined by the single equilibrium static technique (SEST). Fairly good agreementwas observed between both techniques regarding the HLC of 2,4,6-trichlorophenol, 2-methylphenol, and 3-methylphenol. On the basis of the results obtained, it was concluded that the PFI technique offers considerable advantages over SEST in terms of precision, speed, labor intensity, and possibilities for automation.
In order to decontaminate a large area of restricted access contaminated by a fuel spill, laboratory and field studies were developed in two steps: (a) monitoring of the laboratory experiment on bacterial growth under aerobic and anaerobic conditions with and without addition of nutrients; and (b) use of the best conditions obtained in (a) for the decontamination of the soil. A hydraulic barrier was installed both to clean the aquifer and to avoid migration of hydrocarbons as a consequence of their solution in the groundwater and subsequent displacement. The objective was to create an ideal environment for the treatment of the affected area that favoured the growth of the indigenous bacteria (Pseudomonas and Arthrobacter) that biodegrade the hydrocarbons. Monitoring of the changes in the total concentration of petroleum hydrocarbons in the soil subjected to bacterial action was performed by gas chromatography. In a field study, the progress of biodegradation of hydrocarbons was evaluated in situ by changes in subsurface CO2/O2 levels by means of an analyser equipped with an infrared detector. Biostimulation and oxygen were the most influential factors for the biodegradation of the hydrocarbons. The use of bioventing of the soil was shown as an excellent technology to promote in situ bioremediation of the polluted area.
Flow injection methods for the determination of the total polyphenol index, the 'index 280' (I280) and dissolved solids in wines are proposed. The determination of the total polyphenol index is based on the Folin-Ciocalteu reaction in a basic medium and subsequent spectrophotometric detection at 750 nm. The direct measurement at 280 nm of the wine allows the determination of I280 with a simple manifold. The dissolved solids determination is based on the displacement of a light beam when the refractive index of the medium changes. This phenomenon, followed by a change in the absorbance in a photometric detector, usually takes place when an injected sample reaches the flow cell, and it is magnified on passage of the light beam in the radial direction instead of the more common axial direction. The use of a capillary (4 cm x 1.1 mm id) as the flow cell allows monitoring of the injected plug. A simple manifold coupled with a diode array spectrophotometer allows the determination of these parameters with a frequency of at least 90 h-1. Depending of the method adopted for the determination of polyphenols, Folin-Ciocalteu or I280, either a manifold different from that used for determining dissolved solids or the same, respectively, is required. The methods have been successfully applied to different wines and were substantiated well with official methods.
A flow injection method (FI) for the sequential determination of ethanol and acetic acid in vinegar is reported. The determination of ethanol is based on the oxidation of the pervaporated ethanol by K2Cr2O7. The acetic acid is determined by an acid-base reaction with Thymol Blue as the indicator. Both reactions are monitored photometrically at 600 nm using a single detector. Optimisation studies and assessment of the sequential Fl method are also reported. The linear determination range is 0-12% v/v for ethanol and 0-10% (grams of acetic acid in 100 ml) for acetic acid. The sample throughput of the sequential manifold is seven per hour. The new method was applied to vinegar samples and the results obtained were in excellent agreement with those from reference methods used in Spain.
A new method for the extraction-individual separation-determination of polycyclic aromatic hydrocarbons (PAHs) in soil is reported. The method is based on the integration of three steps: continuous subcritical extraction, solid-phase clean-up/preconcentration, and HPLC separation with post-column fluorimetric determination. Sodium dodecyl sulfate (SDS) was added to the water for favouring the extractability of the low-polarity analytes. Soil samples spiked with the target PAHs were subjected to static-dynamic extraction with SDS-water at 50 bar, 150 degrees C, for 15 min of static extraction and 10 min dynamic extraction at a flow-rate of 3 ml/min. Recoveries from 73.6 to 110.4% were obtained in the presence of SDS versus 30 to 80% obtained with water as extractant. The calibration graphs provided by HPLC-fluorimetric detection were run between 0.031 and 0.375 microg/ml for each analyte with regression coefficients between 0.917 and 0.999 and precision, expressed as RSD, between 1.2 and 11.5%. The method was applied to a certified reference material [CRM 524, BCR (Community Bureau of Reference), industrial soil/organic] for validation and the results obtained were in agreement with the certified values.
Continuous subcritical water extraction (CSWE) and hydrodistillation were compared for the extraction of essential oil from marjoram leaves. Ground marjoram leaves (0.4 g) were subjected to dynamic extraction with water at 50 bar, 150 degrees C and 2 ml/min for 15 min. Hydrodistillation was performed treating 140 g of marjoram leaves with 1000 ml of water for 3 h. When CSWE was used the compounds were removed from the aqueous extract by a single extraction with 5 ml of hexane, detected by gas chromatography-flame ionization detection (GC-FID) and identified by mass spectrometry, electronic impact. The CSWE method is quicker (15 min versus 3 h), provides a more valuable essential oil (with higher amounts of oxygenated compounds and no significant presence of terpenes) and allows substantial savings of costs, in terms both of energy and plant material. The efficiency (in terms of volume of essential oil/1 g of plant) of CSWE is 5.1 times higher than that provided by hydrodistillation. The precision of the overall method (CSWE combined with GC-FID) is good (RSD less than 7.5%) for n = 5.
The steps involved in the methods for the determination of vitamin D3 metabolites (namely, 25-hydroxyvitamin D3, 1,25-dihydroxyvitamin D3, 24,25-dihydroxyvitamin D3) mainly in clinical samples are critically reviewed. Sample pretreatment (e.g. deproteinization, saponification, liquid liquid and liquid solid extraction, etc.) as a function of both type of sample and detection system, quantitation based on protein saturation and liquid as well as gas chromatography are discussed. The chemical principles on which the methods are based and the derivatization procedures, which facilitate separation and/or detection, are also commented upon. Finally, the future prospects of the research on methods for the determination of these metabolites are outlined.
A semi-automatic procedure for the continuous clean-up and concentration of several fat-soluble vitamins prior to their separation by HPLC and UV detection is reported. The procedure is based on the use of a minicolumn packed with aminopropylsilica as sorbent located prior to the chromatographic detection system. The overall process was developed and applied to the main liposoluble vitamins (A, D2, D3, E, K1, K3) and several hydroxy metabolites of vitamin D3 [25-(OH)-D3,24,25-(OH)2-D3 and 1,25-(OH)2-D3]. All the analytes were monitored at a compromise wavelength of 270 nm. Calibration graphs were constructed between 0.01 and 100 ng ml-1 for vitamin D2 and D3 and their hydroxy metabolites, between 0.1 and 100 ng ml-1 for vitamin A, K1 and K3 and between 1 and 100 ng ml-1 for vitamin E, with excellent regression coefficients (> or = 0.9901) in all cases. The precision was established at two concentration levels with acceptable RSDs in all instances (between 3.6 and 8.7%). The method was appropriate for the determination of vitamin D2, D3, K1 and K3 and the 24,25-dihydroxy and 25-hydroxy metabolites of vitamin D3 in human plasma. The method was applied to plasma samples spiked with the target analytes and the recoveries ranged between 78 and 109%.