Comparison of three videokeratoscopes in measurement of toric test surfaces.

PURPOSE: We compared the accuracy of the Computed Anatomy TMS-1 (1.41), the EyeSys Laboratories Corneal Analysis System (2.1), and the Visioptic EH-270 (3.0) videokeratoscopes in measuring toric surfaces. These non-rotationally symmetric aspheric surfaces served as models of corneal astigmatism. METHODS: Precision diamond-turned toric surfaces modeling 0.00 diopter (D) to 7.00 D of astigmatism were fabricated. A three-dimensional contact profiler was developed to calibrate the aspheric surfaces. Videokeratoscopic data taken at "best focus" were compared to the theoretical shape to quantify device measurement errors. RESULTS: The Computed Anatomy system measurement accuracy shows no statistically significant correlation between measurement error and surface toricity (r2 < 0.13). Measurement error increased linearly with surface astigmatism for the EyeSys Laboratories system (0.12 D rms error per D of astigmatism, r2 > 0.96, p < 0.001 and the Visioptic system (0.03 D error per D of astigmatism, r2 = 0.88, p < 0.001). CONCLUSIONS: This study found systematic performance differences among the three machines. Under ideal alignment conditions, the Computed Anatomy TMS-1 is more accurate at detecting astigmatism. The EyeSys Laboratories Corneal Analysis System apparently underestimates the amount of surface astigmatism because of excessive data smoothing. The Visioptic EH-270 errors are primarily in the central zones and may be due to ring localization errors.

Algorithms↗

Visual acuity modeling using optical raytracing of schematic eyes.

PURPOSE: We developed a methodology to predict changes in visual performance that result from changes in the optical properties of the eye. METHODS: Exact raytracing of schematic eyes was used to calculate the point spread function and the modulation transfer function of the visual system. The Stiles-Crawford effect, photopic response, diffraction, and the retinal contrast sensitivity are included in the model. Visual acuity was predicted by examining the modulation of the resultant retinal image of a bar target and by determining when the modulation falls below a threshold value. Visual acuity was predicted for refractive errors ranging from 0 to 5 diopters and for pupil diameters ranging from 0.5 to 8 mm. RESULTS: Visual acuity predictions were compared to clinically found Snellen visual acuities and were found to be highly correlated (r2 = .909). CONCLUSIONS: This modeling technique shows promise as a means of evaluating clinical and surgical procedures before undertaking clinical trails.

Contrast Sensitivity↗