PubMed Health⌕ Search

Biomedical subjects

M D Nardin

Publications and source records attributed to M D Nardin.

2 recordsLinked to original sources

A self-oscillating detuning-insensitive class-E transmitter for implantable microsystems.

This paper describes a low-cost, self-oscillating, detuning-in-sensitive, class-E driver for transcutaneous power and data transmission to implantable microsystems. A voltage feedback scheme using a fast comparator for zero-crossing detection and a CMOS start-up circuit were used to stabilize the class-E operation for various transmitter coil inductance values. This technique solves the common problem of mismatch between the switching frequency of the driving device and the resonant frequency of the load network, which can cause excessive power loss and damage to the active device. Data is transmitted by AM modulation of the carrier through switching the power supply between two levels. The transmitter uses a 9-V supply, consumes 212 mA, operates at 3.9 MHz, and has an efficiency of 71%. The efficiency is stable (< 2% change) against 13% variations in the inductance value of a pancake shaped transmitter coil. Index Terms-Biomedical microsystems, class-E transmitter, implantable electronics, inductive powering, transcutaneous links.

Electric Power Supplies↗

A single-channel implantable microstimulator for functional neuromuscular stimulation.

This paper describes a single-channel implantable microstimulator for functional neuromuscular stimulation. This device measures 2 x 2 x 10 mm3 and can be inserted into paralyzed muscle groups by expulsion from a hypodermic needle. Power and data to the device are supplied from outside by RF telemetry using an amplitude-modulated 2-MHz RF carrier generated using a high-efficiency class-E transmitter. The transmitted signal carries a 5-b address which selects one of the 32 possible microstimulators. The selected device then delivers up to 2 microC of charge store in a tantalum chip capacitor for up to 200 microseconds (10 mA) into loads of < 800 omega through a high-current thin-film iridium-oxide (IrOx) electrode (approximately 0.3 mm2 in area). A bi-CMOS receiver circuitry is used to: generate two regulated voltage supplies (4.5 and 9 V), recover a 2-MHz clock from the carrier, demodulate the address code, and activate the output current delivery circuitry upon the reception of an external command. The overall power dissipation of the receiver circuitry is 45-55 mW. The implant is hermetically packaged using a custom-made glass capsule.

Electric Stimulation Therapy↗