PubMed HealthSearch

Biomedical subjects

M D Short

Publications and source records attributed to M D Short.

At least 19 recordsLinked to original sources

A reappraisal of current methods for the assessment of planar gamma camera performance.

This study reappraises the acquisition parameters defined by three current protocols for the specification of planar gamma camera performance. These are the manufacturer Standards of the National Electrical Manufacturers' Association [1] and the International Electrotechnical Commission [2], and the user-orientated protocol of the UK Department of Health (DoH, formerly DHSS) Gamma Camera Performance Assessment Group [3]. The study looks specifically at three major planar performance characteristics: intrinsic non-uniformity, intrinsic spatial resolution and intrinsic non-linearity (spatial distortion). Acquisition parameters specified for these characteristics are investigated by testing a range of values for each parameter around those figures currently advocated by the three protocols. Those acquisition parameters which may be relaxed without loss of data integrity are identified and the adoption of revised parameters for some measurements within the DoH assessment protocol is suggested. Reviewing the data obtained, observations are made regarding the accuracy of some tests performed regularly for quality control purposes. The feasibility and advantages of incorporating some suitably modified DoH performance assessment tests within a routine quality assurance protocol for the gamma camera are also discussed.

Gamma Cameras

Preoperative imaging of colorectal cancers. Targeting the epithelial membrane antigen with a radiation-labeled monoclonal antibody.

The epithelial membrane antigen (EMA) is expressed by the majority of colorectal cancers but has not previously been investigated as a target for radiation-labeled monoclonal antibodies (MoAb) in the imaging of patients with colorectal cancer. A rat IgG2a MoAb that recognizes EMA, ICR2, was labeled with Indium-111 (100 megabecquerel per milligram [MBq/mg]MoAb) using the bicyclic anhydride of the chelating agent diethylene triamine pentacetic acid (ccDTPA) and was administered intravenously to 22 patients known to have or thought to have colorectal cancer. Daily gamma camera imaging was performed for 3 days during the time between the administration of the radiation-labeled antibody and surgical procedure. At operation, the biopsies were done of the tumors and the normal colon, and the uptake of radiation-labeled MoAb was measured in a gamma well-counter. Immunocytochemistry for EMA expression also was done on resected tumors. Independent unblinded and blinded reporting was done on all scans. The sensitivity of 111In-ICR2 for detecting cancers preoperatively was 80% and 60%, respectively, on unblinded and blinded reporting, and the corresponding specificity 20% and 60%. The low unblinded specificity was attributable to a false-positive localization in severely dysplastic benign tumors (n = 2) and inflammatory tissue (n = 2). Liver metastases present in three patients were cold relative to normal liver. Lymph node metastases were localized in 1 of 6 patients preoperatively. The mean absolute uptake of 111In-ICR2 in tumor tissue was 7.75 +/- 3.77 x 10(-3) percent of injected dose per gram, and the ratio to normal colon was 2.10 +/- 0.92:1. On immunohistochemistry, EMA was expressed by 16 of the 17 primary cancers, both dysplastic adenomas, and all nodal metastatic deposits. EMA-negative tumors (1 cancer + 1 colonic lipoma) had negative antibody scans, and patients whose tumor was negative or only focally positive for EMA expression had lower tumor/normal colon ratios of radioactivity (1.30 +/- 0.26 versus 2.45 +/- 0.65, P = 0.005) on gamma well-counting of excised specimens. These results suggest a possible role for 111In-ICR2 in the detection of colorectal cancer and metastases but not its liver deposits.

Aged

Stomach outline visualization in gastrointestinal transit studies using scintigraphy.

A major disadvantage of gamma scintigraphy in gastrointestinal transit studies is the inability to provide adequate delineation of anatomical details. As an aid to the important requirement of outlining the stomach to ensure accurate quantification of the time at which material empties from this organ, a new technique is described, using short half-life 81mKr gas to provide clearer identification of the stomach outline and position.

Gastrointestinal Transit

Intraoperative localization of colorectal cancers using radiolabelled monoclonal antibodies.

Radiation detectors may allow the intraoperative localization of small cancer deposits following administration of radiolabelled tumour-associated antibodies. This technique was evaluated in 16 patients with colorectal tumours (14 cancers, one adenoma, one lipoma) with the 111In-labelled monoclonal antibody (MAb) ICR2 which recognizes the tumour-associated epithelial membrane antigen (EMA). At operation counting was carried out (3 x 20 s per site) using a hand-held radiation probe over the primary lesions and any palpable lymph nodes in the mesocolon. The tumour to normal colon (T/NC) ratio of counts recorded at operation was more than 1.5:1 in eight of the 14 patients with cancer (mean(s.d.), 1.54(0.41):1) and 0.91:1 and 1.06:1 respectively in the two patients with benign tumours. Node to normal colon ratios were higher in lymph nodes containing metastases. The uptake of radiolabelled antibody (T/NC ratio) was higher in EMA-expressing cancers than in those not expressing the target antigen (mean(s.d.), 2.45(0.65):1 versus 1.40(0.20):1, P = 0.019). An abdominal tumour model was also developed. Radioactively filled containers of 0.5-10 ml representing tumour deposits were suspended in a tank of 111In solution representing the background activity found in normal tissues. The ratio of radioactivity in the 'tumour' to that of background varied from 2:1 to 8:1. The 'tumour' was considered to be detectable if the mean counts recorded over the 'tumour' exceeded the mean of counts recorded over background by three standard deviations. At a ratio of 2:1 only 'tumours' greater than 5 ml could be detected with a sodium iodide probe and those over 10 ml could be detected with a cadmium telluride (CdTe) probe. At a ratio of 8:1, 'tumours' of 0.5 ml could be detected with either probe. At all ratios and counting periods the NaI probe was more sensitive than the CdTe.

Aged

Evaluation of a technique for the intraoperative detection of a radiolabelled monoclonal antibody against colorectal cancer.

Occult tumour deposits may be localised at operation with a radiation detecting probe following the administration of a radiolabelled monoclonal antibody (MoAb) recognising a tumour-associated antigen. We have recently evaluated the clinical usefulness of this technique in detecting primary colorectal tumours targetted with an indium-111 MoAb. In the present study the physical characteristics of the two detector systems used were investigated; a sodium iodide [NaI(Tl)] scintillation detector and a cadmium telluride (CdTe) semiconductor probe. Limitations of the technique in use have been examined by testing the statistical significance of tumour detection using an abdominal phantom based on the currently available clinical biodistribution data for tumour uptake of radiolabelled MoAbs. The effect of tumour volume, antibody uptake, collimation and counting conditions was examined. Results indicate that tumours of 10 ml volume may be detected with the NaI(Tl) probe at the lowest levels of radiolabelled antibody uptake currently reported in the literature but that at higher published levels, lesions as small as 1 ml may be identified with both detector systems. Detector sensitivity and limited antibody specificity restrict the usefulness of the technique, although moderate improvements in tumour uptake may allow the detection of tumour deposits not clinically apparent. The statistical significance criterion used for this study could be an accurate and reliable indicator for tumour detection in vivo.

Colorectal Neoplasms

The short-term effects of reducing elevated blood pressure in elderly patients with propranolol and dyazide.

Propranolol and Dyazide (25 mg hydrochlorothiazide and 50 mg triamterene) were used singly to reduce the elevated blood pressure (systolic ranging from 170 to 271 mmHg and diastolic ranging from 100 to 141 mmHg) of 38 elderly hypertensive patients whose ages ranged from 69 to 91 years. Each compound was administered for a period of four weeks with a wash-out period of four weeks in between. The following parameters were assessed before and after each treatment period: cerebral blood flow (CBF), mental functions, cardiac output (CO), electrocardiogram, glomerular filtration rate (GFR) and serum biochemistry. Both systolic and diastolic blood pressure were significantly reduced following the administration of either compound. No significant change in CBF and CO could be observed after reducing the blood pressure whether Propranolol or Dyazide was used. The GFR was, however, significantly reduced and the plasma creatinine significantly increased following Dyazide but not Propranolol administration. As expected the administration of the latter compound was associated with a significant bradycardia. No significant change could be observed in the other parameters studied.

Aged

Which gamma camera?

Performance data on seven currently available gamma cameras have been presented. Where appropriate, results from both the DHSS and NEMA are included. It should be emphasized that no 'best buy' exists for all types of nuclear medicine application and that the performance figures presented in this paper must be interpreted in the light of clinical priorities. No mention has been made of optional extras for a camera system, long-term system reliability, availability of efficient servicing and last but not least, cost. Such details will no doubt be considered as important as the basic performance of the camera. Finally, continued improvements in gamma camera design and performance are likely to necessitate a further communication in the not too distant future.

Equipment Design

Direct labelling of ipratropium bromide aerosol and its deposition pattern in normal subjects and patients with chronic bronchitis.

A technique for the direct labelling of ipratropium bromide with bromine-77, with reconstitution of the drug in a metered dose inhaler so as to be identical to the commercial product, was used to study drug deposition patterns in seven normal subjects and seven patients with chronic bronchitis (mean FEV1 32% (SD 12.2%) predicted normal). The gamma camera image of the thorax was divided into a middle zone--the mediastinal zone--and the lung itself into a central zone comprising its medial third and a peripheal zone, the lateral two thirds. Measurements after 10 inhalations of labelled ipratropium bromide showed similar results for the two groups of subjects. The total lung dose inhaled was 11.2% of 203 micrograms and 11.7% of 186 micrograms in the normal subjects and the patients respectively. In contrast to the deposition patterns seen in aerosol studies using steady state inhalation methods, there was no difference in deposition pattern--that is, the distribution between the central and the peripheral lung zones--between the normal subjects and the patients with airways obstruction.

Adult

Long-term clearance of [57Co]cyanocobalamin in vegans and pernicious anaemia.

1. Whole-body counting has been used to monitor the clearance of [57Co]cyanocobalamin in normal subjects, vegans and patients with pernicious anaemia. After oral administration of 57Co-labelled cyanocobalamin (1 microgram/1 muCi), subjects were counted for radioactivity monthly for a maximum period of 1 year. 2. The results obtained were consistent with a monoexponential clearance model and a least squares fit showed that there was no significant difference between the mean clearance rates for the vegans and normal subjects. 3. The patients with pernicious anaemia cleared the vitamin significantly more quickly than the normal control subjects. 4. This may be due to failure to reabsorb biliary vitamin B12 in pernicious anaemia because of the absence of intrinsic factor.

Adolescent

Contribution of individual differences in gastric emptying to variability in plasma propranolol concentrations.

1 No correlation was found between the rate of gastric emptying and peak plasma propranolol concentrations in six hypertensive patients after single oral doses of 80 mg. 2 In four normal subjects given oral propranolol the peak plasma concentration was highest when a simultaneous injection of metoclopramide and lowest when propantheline was given. The mean time to peak was 1.5 h after metoclopramide, 2.8 h after normal saline and 4.5 h after propantheline. 3 Gastric emptying has some influence on the time of peak plasma propranolol concentrations but individual variation in its bioavailability is determined mainly by first-pass metabolism in the liver.

Administration, Oral

Femoral head activity in Perthes' disease: clinical evaluation of a quantitative technique for estimating tracer uptake.

A method for quantifying the uptake of Tc-99m-labeled phosphate complexes in the femoral head has been clinically evaluated, being used specifically for studying the uptake of these bone-seeking agents in Perthes' disease. The analysis depends on the selection, by computer program, of a reliable reference area in the femoral shaft, which is then compared with the mean uptake from each femoral head. The femoral-head activity is then represented as an uptake ratio. These ratios, together with a fixed contour representing the uptake in the femoral-head regions, provide more clinical information than the radiograph or scintiphoto, particularly in the early stages of unilateral or bilateral femoral-head disease and during followup. No correlation has been found between these ratios and qualitative techniques for assessing Perthes' disease by radiograph. From the quantitative data so far obtained it is clear that osteotomy reduces the vascularity of the femoral head, and in certain cases this reduction persists for some years. Tc-99m-labeled diphosphonate compounds were used in more recent studies, and a significant increase in sensitivity was obtained, compared with earlier polyphosphate data.

Child

A quantitative assessment of femoral head activity using 99Tcm -polyphosphate and a computer data collection system.

Abnormal femoral head activity in Legg-Calve-Perthes' disease has been measured using 99Tcm -polyphosphate and a gamma camera/computer data collection system. A reference point on the data matrix, which is unaffected by the diease, is used for deriving comparative uptake ratios in each femoral head. The reference point remains unaltered after surgical procedures or short intervals between follow-up studies. Early abnormality can be measured in both unilateral and bilateral femoral head pathology.

Child

Adaptive changes in vitamin B12 absorption in celiac disease and after proximal small-bowel resection in man.

Resection of the proximal small bowel is known to cause mucosal hyperplasia and enhanced absorption in the ileum of experimental animals, but similar adaptive changes had not previously been studied in man. Since intrinsic-factor-bound vitamin B12 (IF-B12) absorption is confined to the ileum, as an index of ileal adaptation, we measured whole-body IF-58 Co B12 absorption in 24 control subjects, in 4 patients after proximal small-bowel resection, and in 9 patients with adult celiac disease (where mucosal damage is often limited to the proximal intestine and spares the ileum). Control subjects absorbed 20.4% (+/- 1 SD 6.2%) of the administered 5-mug dose of vitamin B12, while the corresponding 7-day retention values in patients with proximal resection (mean 42.3%; range 32-61%) and in 2 of the 9 celiac patients (44.1% and 54%, respectively), were above the normal range. The increased vitamin B12 absorption in these patients suggest that functional adaptation also occurs in the ileum in man. The results also illustrate the application of a newly developed whole-body counting technique to study vitamin B12 absorption in man.

Adolescent

The diagnosis of renal pseudotumours.

The radiological features of 13 cases of renal pseudotumour due to infolding of the columns of Bertin are presented. 5 of these patients (38%) had partial duplication of the renal pelvis. Pseudotumours show as space-occupying lesions at urography. At angiography they show a clearly defined nephrogram but no abnormal vessels, no pooling of contrast medium and no early venous filling. Radio-isotope scans on 4 cases of pseudotumour showed uptake at the site of the pseudotumour in contrast to cysts and carcinomas which are known to show diminished uptake.

Adult