PubMed Health⌕ Search

Biomedical subjects

M Darowski

Publications and source records attributed to M Darowski.

At least 19 recordsLinked to original sources

Virtual respiratory system for education and research: simulation of expiratory flow limitation for spirometry.

BACKGROUND: Due to economic and ethical problems, virtual organs may appear more convenient than experiments on animals or limited investigations on patients. In particular, a virtual respiratory system (VRS) may be useful for tasks such as respirators and support methods testing, education, staff (medical and technical) training, (initial) testing of scientific hypotheses. METHODS: A comparative study of simulated and real spirometric results for different patient states (healthy lungs, restrictive lung disease, and obstructive lung disease of different localization and degree) was performed. The volume-flow curve and such standard parameters as FEV1, FEV1%VC, MEF75 etc. were analyzed. RESULTS: A mathematical description of collapsing bronchi was proposed. All fundamental phenomena present during spirometry also appeared in VRS, especially characteristic dependence between lung volume and air flow for forced expiration. In particular, both airway resistance and the flow limitation were described with one formula derived from commonly known dependence of the resistance on lung volume. Generally there were no significant differences between simulated results and those seen in clinical practice. Only simulation of obstruction in upper airways gave incorrect results, which suggested a different flow limitation mechanism (perhaps wave-speed limitation). CONCLUSIONS: Our VRS can already be used in medical education, e.g. courses of spirometry, and in some other applications. It seems that the significance of the wave-speed criterion has been overestimated.

Computer Simulation↗

The impact of rotary blood pump in conjunction with mechanical ventilation on ventricular energetic parameters - numerical simulation.

OBJECTIVES: Aim of this work is to study the impact of left ventricular rotary blood pump assistance, on energetic variables, when mechanical ventilation (MV) of the lungs is applied. METHODS: Computer simulation was used to perform this study. Lumped parameter models reproduce the circulatory system. Variable elastance models reproduce the Starling's law of the heart for each ventricle. After the reproduction of ischemic heart disease left ventricular assistance was applied using a model of rotary blood pump. The pump speed was changed in steps and was assumed to be constant during each step. The influence of mechanical ventilation was introduced by different values of positive mean thoracic pressure. RESULTS: The increase of the rotational speed has a significant influence on some ventricular energetic variables. In fact it decreased left ventricular external work, left and right ventricular pressure-volume area and the left ventricular efficiency. Finally, it increased the right ventricular efficiency but had no influence on the right ventricular external work. The increase of thoracic pressure from -2 to +5 mmHg caused a significant decrease of external work, pressure-volume area (right ventricular pressure-volume area dropped up to 50%) and an increase of right ventricular efficiency (by 40%) while left ventricular efficiency remained almost stable. CONCLUSIONS: Numerical simulation is a very suitable tool to predict changes of not easily measurable parameters such as energetic ventricular variables when mechanical assistance of heart and/or lungs is applied independently or simultaneously.

Computer Simulation↗

Modelling in the study of interaction of Hemopump device and artificial ventilation.

The aim of this work is to evaluate in different ventricular conditions the influence of joint mechanical ventilation (MV) and Hemopump assistance. To perform this study, we used a computer simulator of human cardiovascular system where the influence of MV was introduced changing thoracic pressure to positive values. The simulation confirmed that haemodynamic variables are highly sensitive to thoracic pressure changes. On the other hand, Hemopump assistance raises, among the others, mean aortic pressure, total cardiac output (left ventricular output flow plus Hemopump flow) and coronary flow. The simulation showed that the joint action of Hemopump and positive thoracic pressure diminishes these effects.

Air Pressure↗

Development of a hybrid (numerical-hydraulic) circulatory model: prototype testing and its response to IABP assistance.

Merging numerical and physical models of the circulation makes it possible to develop a new class of circulatory models defined as hybrid. This solution reduces the costs, enhances the flexibility and opens the way to many applications ranging from research to education and heart assist devices testing. In the prototype described in this paper, a hydraulic model of systemic arterial tree is connected to a lumped parameters numerical model including pulmonary circulation and the remaining parts of systemic circulation. The hydraulic model consists of a characteristic resistance, of a silicon rubber tube to allow the insertion of an Intra-Aortic Balloon Pump (IABP) and of a lumped parameters compliance. Two electro-hydraulic interfaces, realized by means of gear pumps driven by DC motors, connect the numerical section with both terminals of the hydraulic section. The lumped parameters numerical model and the control system (including analog to digital and digital to analog converters)are developed in LabVIEW environment. The behavior of the model is analyzed by means of the ventricular pressure-volume loops and the time courses of arterial and ventricular pressures and flows in different circulatory conditions. A simulated pathological condition was set to test the IABP and verify the response of the system to this type of mechanical circulatory assistance. The results show that the model can represent hemodynamic relationships in different ventricular and circulatory conditions and is able to react to the IABP assistance.

Analog-Digital Conversion↗

In vivo and simulation study of artificial ventilation effects on energetic variables in cardiosurgical patients.

OBJECTIVES: The analysis of energetic ventricular variable changes during artificial ventilation, obtained by numerical simulation was done. Twenty-one sets of hemodynamic parameters for eight cardiosurgical patients were used to estimate left and right stroke work. The data were collected for three methods of ventilation: conventional, lung-protective (with minute ventilation diminished by half) and high frequency ventilation (with frequency 5, 10, or 15 Hz). METHODS: The computer simulator (CARDIOSIM) of the cardiovascular system, was used as a tool to calculate values of energetic ventricular variables for conditions that corresponded to these during in vivo measurements. Different methods of ventilation caused differences of intrathoracic pressure, haemodynamic and finally energetic ventricular variables. The trends of these variable changes were the same in in vivo and simulation studies, in the whole range of intrathoracic pressure changes (Pt = 1.5-3.5 mmHg). RESULTS: As values of main hemodynamic variables like cardiac output or arterial, systemic and pulmonary pressures were very close in both studies. Cardiac index and left ventricular stroke work also differed less than 10% for all examined patients and computer simulation. In a case of right ventricular stroke work the difference between in vivo data and simulation was a bit greater than 10% for two of eight patients under study. CONCLUSIONS: Our comparative analysis proved that numerical simulation is a very useful tool to predict changes of main hemodynamic and energy-related ventricular variables caused by different levels of positive Pt. It means that it can help an anesthesiologist to choose an appropriate method of artificial ventilation for cardiosurgical patients.

Computer Simulation↗

A hybrid mock circulatory system: development and testing of an electro-hydraulic impedance simulator.

Mock circulatory systems are used to test mechanical assist devices and for training and research purposes; when compared to numerical models, however, they are not flexible enough and rather expensive. The concept of merging numerical and physical models, resulting in a hybrid one, is applied here to represent the input impedance of the systemic arterial tree, by a conventional windkessel model built out of an electro-hydraulic (E-H) impedance simulator added to a hydraulic section. This model is inserted into an open loop circuit, completed by another hybrid model representing the ventricular function. The E-H impedance simulator is essentially an electrically controlled flow source (a gear pump). Referring to the windkessel model, it is used to simulate the peripheral resistance and the hydraulic compliance, creating the desired input impedance. The data reported describe the characterisation of the E-H impedance simulator and demonstrate its behaviour when it is connected to a hybrid ventricular model. Experiments were performed under different hemodynamic conditions, including the presence of a left ventricular assist device (LVAD).

Computer Simulation↗

Modelling of cardiovascular system: development of a hybrid (numerical-physical) model.

Physical models of the circulation are used for research, training and for testing of implantable active and passive circulatory prosthetic and assistance devices. However, in comparison with numerical models, they are rigid and expensive. To overcome these limitations, we have developed a model of the circulation based on the merging of a lumped parameter physical model into a numerical one (producing therefore a hybrid). The physical model is limited to the barest essentials and, in this application, developed to test the principle, it is a windkessel representing the systemic arterial tree. The lumped parameters numerical model was developed in LabVIEW environment and represents pulmonary and systemic circulation (except the systemic arterial tree). Based on the equivalence between hydraulic and electrical circuits, this prototype was developed connecting the numerical model to an electrical circuit--the physical model. This specific solution is valid mainly educationally but permits the development of software and the verification of preliminary results without using cumbersome hydraulic circuits. The interfaces between numerical and electrical circuits are set up by a voltage controlled current generator and a voltage controlled voltage generator. The behavior of the model is analyzed based on the ventricular pressure-volume loops and on the time course of arterial and ventricular pressures and flow in different circulatory conditions. The model can represent hemodynamic relationships in different ventricular and circulatory conditions.

Coronary Circulation↗

Study of systolic pressure variation (SPV) in presence of mechanical ventilation.

Systolic pressure variation (SPV) and its components (dUp and dDown) have been demonstrated to be of interest in assessing preload in mechanically ventilated patients. The aim of this paper is to analyse the sensitivity of these variables to preload and volemic changes during mechanical ventilation in different conditions of the cardiovascular system. Computer simulation experiments have been done using a modular lumped parameter model of the cardiovascular system. The effect of mechanical ventilation has been reproduced operating on intrathoracic pressure. Experiments have been performed varying preload through filling pressure. Sensitivity of SVP dUp and dDown is described varying separately left ventricular elastance (Ev), systemic arterial resistance (Ras) and systemic arterial compliance (Cas). The sensitivity of SPV and dDown to preload and filling pressure is appreciable for high values of Ev and for a wide variation of Ras. Preliminary clinical data concerning the three parameters show good correlation with simulation results.

Blood Pressure↗

Cerebral function monitoring in paediatric intensive care: useful features for predicting outcome.

Neurological integrity in sick children is difficult to assess clinically. The aim of this study was to determine the predictive value of EEG activity recorded with a bedside EEG analysing monitor in an intensive care unit. EEG activity was monitored in 108 children (age range 2 weeks to 16 years, median 1.7 years) considered at risk for cerebral abnormalities with a cerebral function analysing monitor (CFAM). Recordings were evaluated for features of background EEG activity including mean amplitude, frequencies, and symmetry. Electrical seizure activity was quantified if present. Predictive value of the EEG features was evaluated relative to the clinical neurological outcome after one year. Asymmetrical recordings were not seen in any child with a normal outcome. Suppression of background activity was seen in 75% of the children who died. Seizures were present in 68% of children with a poor outcome. Seventeen of the 32 children (65%) who died had prolonged seizures. Absence of seizures and the presence of superimposed fast EEG activity in response to benzodiazepine infusions correlated with good outcome. A combination of two or more predictive EEG features demonstrated >90% specificity and positive predictive likelihood of poor outcome. EEG features provide information about the functional cerebral integrity of sick children. Changes in cerebral activity detected by the CFAM aid decision making by providing such information readily at the bedside in intensive care.

Adolescent↗

Computer simulation of haemodynamic parameters changes with left ventricle assist device and mechanical ventilation.

Left Ventricular Assist Device is used for recovery in patients with heart failure and is supposed to increase total cardiac output, systemic arterial pressure and to decrease left atrial pressure. Aim of our computer simulation was to assess the influence of Left Ventricular Assist Device (LVAD) on chosen haemodynamic parameters in the presence of ventilatory support. The software package used for this simulation reproduces, in stationary conditions, the heart and the circulatory system in terms of pressure and volume relationships. Different circulatory sections (left and right heart, systemic and pulmonary arterial circulation, systemic and pulmonary venous circulation) are described by lumped parameter models. Mechanical properties of each section are modelled by RLC elements. The model chosen for the representation of the Starling's law of the heart for each ventricle is based on the variable elastance model. The LVAD model is inserted between the left atrium and the aorta. The contractility of the heart and systemic arterial resistance were adjusted to model pathological states. Our simulation showed that positive thoracic pressure generated by mechanical ventilation of the lungs dramatically changes left atrial and pulmonary arterial pressures and should be considered when assessing LVAD effectiveness. Pathological changes of systemic arterial resistance may have a considerable effect on these parameters, especially when LVAD is applied simultaneously with mechanical ventilation. Cardiac output, systemic arterial and right atrial pressures are less affected by changes of thoracic pressure in cases of heart pathology.

Animals↗

Artificial ventilation of the lungs for emergencies.

The necessity for extraordinary ventilatory support may appear in different places all over the world in cases of a massive disaster (industrial or natural), connected with gas poisoning on a huge scale. Hospitals equipped with limited number of respirators, adequate for peacetime activity, are not able to meet suddenly multiplied requirements for ventilatory support. This paper describes a preliminary study to develop a convenient, reliable method of performing artificial ventilation of at least two patient by means of only one ventilator. We developed a unique, new control system (patent pending) which, when placed between a respirator and endotracheal tubes of the patients, divides the total tidal volume between the patients' lungs and controls pressures at their airways. A special arrangement of valves in the control system enables us to separate inspiratory and expiratory paths for each patient and to avoid cross-infection. The model study performed, according to ISO standards, on mechanical test lungs has shown that the proposed control system enables us to adjust ventilatory parameters at desired values, when lung compliance or respiratory airway resistance differ. The proposed one-source artificial ventilation is a simple solution to provide ventilatory support when the number of patients is greater than the number of respirators that are available.

Accidents, Occupational↗

Heart and lung support interaction--modeling and simulation.

Mechanical support of the lungs used to preserve life or during any kind of surgery may have an adverse effect on the cardiovascular system. Usually, positive pressure in alveoli diminishes lung perfusion, venous return and cardiac output. Positive pressure during the respiratory cycle is transfered into the thoracic space. The aim of this study was to assess how synchronization of the respirator with spontaneous breathing influences the distribution of pressure and ventilation in nonhomogeneous lungs and how it should influence hemodynamics. For this purpose a multicompartmental model of respiratory system mechanics was used in the electrical analog of a respirator-lung circuit, which enabled us to simultaneously simulate ventilatory support and spontaneous breathing. Mechanical properties of the respiratory system were modeled by lumped parameters: resistances and capacitances of constant values, independent of lung volume or inspiratory flow changes. A multicompartmental model of the respiratory system enabled us to simulate lung pathology characterized by non-homogeneity of the mechanical properties of the different parts of the lungs. The results of simulations presented in the paper enable us to conclude that lung volume increase, independent of the respirator-patient breathing synchronization, may be modeled as the increase in pulmonary vascular resistance and alveolar pressure increase, dependent on respirator-patient breathing synchronization, may be averaged by esophageous balloon measurements which show intrathoracic pressure changes.

Cardiovascular Physiological Phenomena↗

Computer simulation of hemodynamic parameter changes by mechanical ventilation and biventricular circulatory support.

When a Bi-Ventricular Assist Device (BVAD) is used in conjunction with mechanical ventilation (MV) of the lungs with positive intrathoracic pressure (Pt), the latter influences hemodynamics. The aim of our study was to assess the simultaneous influence of BVAD and MV on hemodynamics. We assumed ventricular pathological conditions as reduced elastances and increased rest volumes. Peripheral systemic arterial resistance was assumed to have different values. Data were obtained by computer simulation. Trends in main hemodynamic variables were compared with clinical data from literature. Simulation showed that systemic venous, pulmonary arterial and left atrial pressures are very sensitive to Pt (-2 to 5 mmHg).

Computer Simulation↗

Abnormal surfactant composition and activity in severe bronchiolitis.

A prospective study of infants under 1 y of age, ventilated for severe viral bronchiolitis, was carried out in four paediatric intensive care units in order to study surfactant activity and composition in this condition. Lung lavage fluid from 24 infants with bronchiolitis, 19 with bronchiolitis and sepsis or cardiac failure and 12 controls were analysed by the "click test" for surfactant activity and for phospholipids. Surfactant activity was present in all controls, but in only 2 of the 24 infants with bronchiolitis alone. The presence of phosphatidylglycerol correlated perfectly with the click test, suggesting that reduced activity is due to changes in surfactant lipid composition. In those with bronchiolitis plus coexisting disease, surfactant activity and phosphatidylglycerol were absent in only half. Surfactant activity and phosphatidylglycerol re-appeared by extubation. Severe viral bronchiolitis is associated with an absence of surfactant activity and PG, which resolves by clinical recovery. Infants with coexisting conditions are not always surfactant deficient. Surfactant administration is likely to be beneficial, but requires a selective approach.

Bronchiolitis↗

The influence of simultaneous intra-aortic balloon pumping and mechanical ventilation on hemodynamic parameters--numerical simulation.

Intra-aortic balloon counterpulsation (IABC) is one of the methods to assist circulation. Its application is supposed to increase coronary blood flow (Qcor) and myocardial oxygen supply. Mechanical ventilation of the lungs causes some side effects that influence mainly hemodynamics, i.e. it decreases cardiac output (CO) and systemic aortic pressure (Pas) but increases systemic venous pressure (Pvs). The aim of this study was to assess the influence of IABC on hemodynamic parameters when mechanical ventilation of the lungs is used as well. We assumed pathological conditions of the heart as reduced left ventricle elastance (Ev = 0.77 mmHg/cm3) and increased left ventricle rest volume (V0 = 10 cm3). Also peripheral systemic arterial resistance (Ras) took three different values. CARDIOSIM, a computer simulator of the human cardiovascular system, was used to assess the changes of hemodynamic parameters [CO, Pas, Pvs, and pulmonary arterial pressure (Pap)] when IABC and mechanical ventilation of the lungs were applied simultaneously. Computer simulation showed that application of IABC increased such variables as CO (by approximately equal to 17%), maximum value of Pas (by approximately equal to 20%), while left atrial pressure (Pla) was diminished (by approximately equal to 30%). On the other hand, Pvs and Pap were not strongly affected by IABC, but they were dramatically dependent on intrathoracic pressure. This means that Pvs, Pap, and Pla should be carefully monitored during IABC and artificial ventilation.

Blood Pressure↗

The influence of left ventricle assist device and ventilatory support on energy-related cardiovascular variables.

One of the main purposes in using Left Ventricle Assist Devices (LVAD) to assist recovery in patients with heart failure, is to reduce the external work (EW) of the left natural ventricle. The simultaneous presence of mechanical ventilatory support can affect the value of this variable. The aim of our computer simulation was to trace the influence of LVAD on EW, cardiac mechanical efficiency (CME) and pressure volume area (PVA) in the presence of ventilatory support. Pathological conditions of the heart were reproduced. Peripheral systemic arterial resistance (Ras) was also changed to model physiological and pathological states. The influence of mechanical ventilation was introduced by changing levels of mean thoracic pressure. In this way we were able to predict changes of EW, CME and PVA in both ventricles, during ventilatory (mechanical) and cardiovascular (LVAD) support. Our simulation showed that positive thoracic pressure seems to affect the energy-related cardiovascular variables and should be taken into account during the assessment of LVAD effectiveness. Pathological changes of systemic peripheral resistance have a considerable effect on EW, CME and PVA of left ventricle. On the other hand energy-related parameters of the right ventricle are not especially affected by changes in systemic peripheral resistance.

Computer Simulation↗