Left ventricular assist device as bridge to heart transplantation--lessons learned with the MicroMed DeBakey axial blood flow pump.

OBJECTIVE: The MicroMed DeBakey left ventricular assist device (LVAD) axial blood flow pump was used as bridge to heart transplantation (HTx) in patients with terminal heart failure. The aim was to evaluate this novel mechanical circulatory support system in regard to overall outcome. METHODS: Prospective study in 15 HTx candidates (mean age 40+/-7 years) with terminal heart failure and maximal medical treatment due to ischemic cardiomyopathy (CMP, n=5), dilated CMP (n=3), restrictive CMP (n=2), unclassified CMP (n=1), metabolic CMP (n=1), valvular CMP (n=1) and congenital CMP (n=2). All patients were implanted with a MicroMed DeBakey LVAD. A rescue procedure was necessary in eight critical patients, while seven underwent elective LVAD implantation. Procedures were performed via median sternotomy, in normotherm femoro-femoral CPB (mean duration 59+/-1 min). Oral Marcoumar (INR 2.0-3.0) and Aspirin (100 mg daily) were started as soon as possible. Patients were discharged into a specialized rehabilitation clinic from which it was possible to release them home after a few weeks. RESULTS: Successful implantation and discharge from ICU (mean stay 10+/-7 days) was possible in 11 patients. Seven were transplanted (mean support 50.7 days) and one is awaiting HTx (support >310 days) in the comfort of his home (NYHA I). Survival was 100% among the transplanted patients. Of the seven elective implants, five, and of the eight rescue procedures three patients underwent successful HTx. Four patients died early, while three patients died late on pump support due to intracranial hemorrhage (n=2, 73 and 76 days) and chest infection (n=1, 124 days). All survivors were discharged from hospital, with significant decrease in NYHA class (mean 3.8-2.4 (n=11)). Treadmill testing showed increased exercise tolerance, from 35 to 71W (n=4). Plasma BNP values (mean 950-162 ng/l (n=4)) and pulmonary resistance (mean 316-194.5 dyne s/cm(5) (n=3)) decreased significantly during LVAD support. CONCLUSIONS: The MicroMed DeBakey LVAD is simple to implant; outpatient treatment is safe and efficient. Patients' condition and pulmonary resistances normalize within 6 weeks, making previously considered inoperable patients amenable for HTx. HTx can be performed in low-risk situation, allowing better donor-recipient matching and improving overall outcome.

Adolescent↗

First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation.

BACKGROUND: A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. METHODS AND RESULTS: Two male patients (ages 44 and 65 years) suffering from end-stage left heart failure were implanted with a DeBakey VAD axial-flow pump for use as a bridge to transplant. In the initial postoperative period, the mean pump flow was 3.9+/-0.5 L/min, which equals a mean cardiac index (CI) of 2.3+/-0.2 L. min(-1). m(-2). In both patients, the early postoperative phase was characterized by a completely nonpulsatile flow profile. However, with the recovery of heart function 8 to 12 days after implantation, increasing pulse pressures became evident, and net flow rose to 4.5+/-0.6 L/min, causing an increase of mean CI up to 2.7+/-0.2 L. min(-1). m(-2). Patients were mobilized and put through regular physical training. Hemolysis stayed in the physiological range and increased only slightly from 2. 1+/-0.8 mg/dL before surgery to 3.3+/-1.8 mg/dL 6 weeks after implantation. CONCLUSIONS: The first clinical implants of the DeBakey VAD axial-flow pump have demonstrated the device to be a promising measure of bridge-to-transplant mechanical support.

Adult↗

Left and right pump output control in one-piece electromechanical total artificial heart.

Left master alternate (LMA) ejection control based on the left pump fill method was implemented for a one-piece electromechanical total artificial heart (TAH). The TAH consists of left and right pusher-plate-type blood pumps sandwiching a compact electromechanical actuator comprising a direct current (DC) brushless motor and a planetary roller screw. The motor rotation is controlled on the basis of the roller-screw position as detected by a Hall effect sensor and a commutation pulse counting method. Since the pusher-plate shaft and roller screw are decoupled during filling, both pumps fill passively with the right and left atrial pressure. To obtain response to the right atrial pressure change in the LMA mode, the left fill trigger level as detected by a Hall effect position sensor is adjusted to operate the pump at a higher rate and to drive the right pump at 85-90% of the full stroke level. The in vitro evaluation demonstrated that this method can respond to right atrial pressure changes provided that the right pump is operated at less than the full stroke level. When the preload is high and the right pump goes into full stroke operation, the left eject level can be decreased to run the pump at a higher rate and to transfer more blood from the right to the left. In the in vivo evaluation, which lasted 1 week in a 95 kg calf, the left and right atrial pressures were kept within physiological ranges.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

A unique, efficient, implantable, electromechanical, total artificial heart.

A completely implantable, one piece electromechanical total artificial heart (TAH) intended for permanent human use was developed. It consisted of left and right conically shaped pusher-plate blood pumps sandwiching a thin centerpiece with a compact, efficient electromechanical actuator. The actuator consisted of a direct current brushless motor; a planetary roller screw fit the space between the two conically shaped pusher-plates. The rotational motion of the motor was converted to the rectilinear motion of the rollerscrew to displace the left and right pusher-plates in the left master alternate mode. The diameter of the assembled TAH was 97 mm, with a central thickness of 82 mm. The overall weight was 620 g, with a displaced volume of 510 ml. The pump provided flows of 3-8 L/min with a preload of 1-15 mmHg against an afterload of 100 mmHg. The net efficiency ranged from 15% to 18%. This model showed good fit in the pericardial space of heart transplant recipients (body weight, 77 kg).

Cardiac Output↗