PubMed Health⌕ Search

Biomedical subjects

M Deli

Publications and source records attributed to M Deli.

11 recordsLinked to original sources

[MRI of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen].

PURPOSE: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. MATERIAL AND METHODS: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. RESULTS: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. CONCLUSION: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery.

Alloys↗

[Precision and comparison of CT-, MRI- and DL-controlled interventions exemplified by lumbar facet infiltration--an experimental study].

We evaluated the accuracy of the needle tip representation by different imaging techniques for the guidance of facet infiltrations. For visualisation of the lumbar facet joints we used a high-field magnetic resonance tomograph (MRT) with a 2.0 Tesla field and 3.5 mm slice thickness, an open low-field magnetic resonance tomography (MRT) with an 0.064 Tesla field and 9 mm slice thickness, and IMATRON electron beam computed tomograph (EBCT) with a slice thickness of 6 mm, and a mobile C-arm fluoroscope. The study was performed on 4 human cadaveric lumber spine preparations, each of which had 8 facet joints. Under imaging control, special injection needles were placed as close as possible to the facet joint space. Following placement of he needle, all specimens were scanned with the electron beam tomograph using a slice thickness of 1.5 mm. The thin-slice study served as the gold standard. The distance between the tip of the needle and the facet joint was measured in all the images. Comparison of the different modalities with the gold standard revealed the following results: 1) median values of the absolute differences were 1.25 mm for high-field MRI, 1.35 mm for 6 mm EBCT, 2.05 mm for low-field MRI, and 2.30 mm for X-ray fluoroscopy. 2) While there was no statistically significant difference in the accuracy of tip localization between high-field MRI and 6" EBCT (p = 0.293), both systems were more precise than low-field MRI (p = 0.04) and X-ray fluoroscopy (p = 0.009). When choosing the best imaging technique, such additional factors as radiation, costs and time, must also be considered. Provided necessary radiological precautions are taken, and assuming careful pre-interventional planning, CT. EBCT and X-ray fluoroscopy are currently more effective than the expensive, time-consuming and costly magnetic resonance tomography.

Equipment Design↗

Mercury-stimulated histamine uptake and binding in cultured astroglial and cerebral endothelial cells.

The effects of mercuric compounds on histamine uptake and binding to uptake carrier in cultured rat astroglial and cerebral endothelial cells were investigated. Experimental results showed that mercuric compounds produced strong stimulation of glial and cerebroendothelial histamine uptake over a concentration range of 25-500 microM. The stimulated histamine uptake showed characteristics similar to those described for basal uptake in terms of sensitivity to inhibitory agents (e.g., impromidine) and the requirement of external Na+. Mercury-induced stimulation of histamine uptake could be abolished by sulfhydryl agents, dithiotreitol and cysteamine, indicating a complete reversal of, and not simply a protection from, the action of mercury. Basal and stimulated uptake of histamine represent bindings to uptake carrier with high and closely equal affinities but markedly higher capacities for stimulated uptake. In controls, the mean value of apparent KD (derived from saturation kinetics at equilibrium) was obtained as 26.7 +/- 3.9 nM for astroglial cells; and 100 microM mercuric chloride did not modify it significantly. In contrast, the apparent Bmax values differed markedly; found as 0.63 +/- 0.10 pmol/mg protein and 3.32 +/- 0.47 pmol/mg protein in the absence and the presence of 100 microM mercuric chloride respectively. For the cerebral endothelial cell line, RBE4, the apparent KD was calculated as 22.5 +/- 3.2 nM and was comparable to that obtained for astroglial cells in control and mercury-stimulated conditions. The apparent Bmax values were less, but markedly different in these conditions, obtained as 0.18 +/- 0.03 pmol/mg protein and 1.2 +/- 0.36 pmol/mg protein in the absence and the presence of mercuric ion respectively. In both cells, impromidine, the potent inhibitor of basal and stimulated histamine uptake, decreased the enhanced capacities of histamine binding (Bmax) (without affecting the dissociation constant, KD) in micromolar range, comparable to its inhibiting potency. Results confirmed that mercuric ion might enhance the binding capacity of histamine carrier and protein sulfhydryls might play a role in this effect. The observed stimulations by mercuric compounds suggest close similarities in the mechanism of histamine uptake and the structure of histamine carrier in astroglial and cerebral endothelial cells.

Animals↗

Equipment configuration and procedures: preferences for interventional microtherapy.

Magnetic resonance imaging (MRI), computed tomography, and electron beam tomography scanners are built for radiologic diagnosis. With increasing frequency they are being used in the field of interventional Microtherapy to permit transparent visualization of the therapeutic field. Each of these scanners can be combined with endoscopy, fluoroscopy/digital subtraction angiography, and ultrasound units for hybrid imaging techniques as well as with therapeutic systems like lasers or radiofrequency. MRI affords 3D localization without x-ray exposure. Open access and keyhole imaging allow nearly real time guidance of instruments. Minimally invasive techniques using endoscopes and hybrid tomographic guidance result in improved tip tracking of microinstruments and reduced complications. This safer access into the body will lead to interdisciplinary cooperation with the potential for large cost reductions. This report summarizes our experience regarding which of the hybrid imaging suites is best suited for procedures including among others drug instillations, prosthesis (stent) implantation, or microoperations (endoscopic diskectomy/sequestrectomy), and physiological measurements simultaneously.

Diagnostic Imaging↗

MRI-guided endoscopy in the brain: a feasability study.

For neuronavigation in neuroendoscopy conventional navigation systems cannot exclude tissue movements caused by loss of cerebrospinal fluid (CSF). Open MRI can serve as a real-time navigation system if special conditions of endoscopic instruments and equipment are followed. We adapted an endoscopic system to the MRI and installed a miniaturized laser guidance system to project the central transaxial and coronal planes onto the phantom. A human cadaveric model was examined with a flexible microendoscope marked with a titanium wire inside the open magnet. The procedures were guided by gradient echo sequences refreshing the image every 4.5 seconds to control position of the endoscope. Endoscopic and corresponding MRI-findings are presented. Results and technical conditions are discussed.

Artifacts↗

Expression of protein kinase C family members in the cerebral endothelial cells.

The protein kinase C (PKC) family is composed of at least four conventional (alpha, beta I, beta II, and gamma) and several related novel (delta, epsilon, eta, and zeta) isoforms with different distribution and sensitivity to Ca2+ and phorbol esters. The enzyme is known to be present in cerebral endothelial cells. We have investigated the occurrence of seven isoforms (alpha, beta, gamma, delta, epsilon, eta, and zeta) by using reverse transcriptase-polymerase chain reaction in rat brain, in a freshly isolated brain microvessel fraction, in primary cultures of rat brain endothelial cells, in an immortalized rat brain endothelial cell line, and in aortic endothelial cell cultures. Brain tissue contained all seven investigated isoforms. A similar expression pattern was seen in freshly purified microvessels, but the PKC-gamma isoform could not be detected. Primary cultures of endothelial cells expressed PKC-alpha, -beta, -delta, -eta, and -epsilon isoenzymes, whereas the immortalized cell line expressed PKC-alpha, -delta, -epsilon, and -eta. The rat aortic endothelium contained only PKC-alpha and -delta isoforms. The variety of expression patterns of PKC family members in endothelial cells of different type may reflect differences in the functional responsiveness to environmental stimuli. Because PKC has been shown to be involved in the regulation of the blood-brain barrier permeability, the presence of different isoforms may confer a sophisticated intracellular regulatory mechanism to the brain endothelial cells.

Animals↗

In situ hybridization with digoxigenin labeled oligonucleotide probes: detection of CAMK-II gene expression in primary cultures of cerebral endothelial cells.

A better understanding of the regulation of gene expression under physiological and experimental conditions is one of the most important goals of today's neurobiology. In order to accomplish this task a number of in-situ hybridization methods have been elaborated. In the past few years the use of nonradioactive procedures have gained more and more space among these efforts. One of the most promising methods in this field is the application of digoxigenin-labeled probes, which have been used successfully in several laboratories. Here we present a rapid method providing good spatial resolution and low background labeling for the detection of messenger RNAs in various cell culture systems using digoxigenin-labeled probes. By using oligonucleotides complementary to the alpha and beta subunit of the calcium/calmodulin dependent protein kinase II (CAMK-II) we were able to demonstrate the presence of this enzyme in cultured cerebral endothelial cells, an enzyme that plays an important role in mediating the effects of extracellular signals.

Animals↗

[Tooth extraction in surgical orthodontic treatment of malformations of the facial mass].

In the present article the Authors take under consideration the most important role of the presurgical orthodontic treatment from the point of view of the orthodontic techniques which aim to improve the occlusion. The authors, therefore describe the different faces, and they focalize the fact that the therapy may frequently require extractions to resolve serious crowdings of the teeth. They take also care of the maxillo facial skeleton alterations, to decide on extracting and about the ratio between the space available and required in the different cases.

Adult↗