PubMed Health⌕ Search

Biomedical subjects

M Di Michiel

Publications and source records attributed to M Di Michiel.

7 recordsLinked to original sources

Synergy of gene-mediated immunoprophylaxis and microbeam radiation therapy for advanced intracerebral rat 9L gliosarcomas.

PURPOSE: Microbeam radiation therapy (MRT), a novel experimental radiosurgery that largely spares the developing CNS and other normal tissues, is tolerated well by developing animals and palliates advanced 9LGS tumors. This report, to our knowledge, is the first demonstration that gene-mediated immunotherapy (GMIMPR) enhances the efficacy of MRT for advanced 9LGS tumors. METHODS: Seventy-six male Fischer 344 rats were implanted ic with 10(4)9LGS cells on d0. By d14, the cells had generated approximately approximately 40 mm3 ic 9LGS tumours, experimental models for therapy of moderately aggressive human malignant astrocytomas. Each of the 14 untreated (control) rats died from a large (>100 mg) ic tumor before d29 (median, d21). On d14, the remaining 62 rats were given deliberately suboptimal microbeam radiation therapy (MRT) by a single lateral exposure of the tumor-bearing zone of the head to a 10.1 mm-wide, approximately approximately 11 mm-high array of 20-39 microm-wide, nearly parallel beams of synchrotron wiggler-generated radiation (mainly approximately 50-150 keV X-rays) that delivered 625 Gy peak skin doses at approximately approximately 211 microm ctc intervals in approximately approximately 300 ms either without additional treatments (MRT-only, 25 rats), with post-MRT GMIMPR (MRT+GMIMPR, 23 rats: multiple sc injections of irradiated (clonogenically-disabled) GM-CSF gene-transfected 9LGS cells), or with post-MRT IMPR (MRT+IMPR, 14 rats: multiple sc injections of irradiated (clonogenically-disabled) 9LGS cells. RESULTS: The median post-implantation survivals of rats in the MRT-only, MRT+GMIMPR and MRT+IMPR groups were over twice that of controls; further, approximately approximately 20% of rats in MRT-only and MRT+IMPR groups survived >1 yr with no obvious disabilities. Moreover, over 40% of MRT+GMIMPR rats survived >1 yr with no obvious disabilities, a significant (P<0.04) increase over the MRT-only and MRT+IMPR groups. SIGNIFICANCE: These data suggest that the combination of MRT+GMIMPR might be better than MRT only for unifocal CNS tumors, particularly in infants and young children.

Age Factors↗

Simultaneous tomography and diffraction analysis of creep damage.

Creep damage by void nucleation and growth limits the lifetime of components subjected to loading at high temperatures. We report a combined tomography and diffraction experiment using high-energy synchrotron radiation that permitted us to follow in situ void growth and microstructure development in bulk samples. The results reveal that void growth versus time follows an exponential growth law. The formation of large void volumes coincides with texture evolution and dislocation density, reaching a steady state. Creep damage during a large proportion of sample creep life is homogeneous before damage localization occurs, which leads to rapid failure. The in situ determination of void evolution in bulk samples should allow for the assessment of creep damage in metallic materials and subsequently for lifetime predictions about samples and components that are subject to high-temperature loading.

Journal Article↗

MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility.

Preclinical experiments are carried out with approximately 20-30 microm wide, approximately 10 mm high parallel microbeams of hard, broad-"white"-spectrum x rays (approximately 50-600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate and/or unsafe. Novel physical microdosimetry (implemented with MOSFET chips in the "edge-on" mode) and Monte Carlo computer-simulated dosimetry are described here for selected points in the peak and valley regions of a microbeam-irradiated tissue-equivalent phantom. Such microbeam irradiation causes minimal damage to normal tissues, possible because of rapid repair of their microscopic lesions. Radiation damage from an array of parallel microbeams tends to correlate with the range of peak-valley dose ratios (PVDR). This paper summarizes comparisons of our dosimetric MOSFET measurements with Monte Carlo calculations. Peak doses at depths <22 mm are 18% less than Monte Carlo values, whereas those depths >22 mm and valley doses at all depths investigated (2 mm-62 mm) are within 2-13% of the Monte Carlo values. These results lend credence to the use of MOSFET detector systems in edge-on mode for microplanar irradiation dosimetry.

Animals↗

Tissue lesions caused by microplanar beams of synchrotron-generated X-rays in Drosophila melanogaster.

PURPOSE: To examine tissue lesions caused by microplanar beams of synchrotron-generated X-rays in Drosophila melanogaster using stereomicroscopy, light and electron microscopy. MATERIALS AND METHODS: Pupae were irradiated by 25-microm wide, 1.175 mm-high parallel microplanes at 100 microm on-centre intervals, at 20, 24, 32, 36, 48 or 72 h of development, with absorbed doses per microplane between 75 and 3,000 Gy. RESULTS: Transverse or longitudinal irradiation with in-slice absorbed doses of 75 or 375 Gy caused no recognizable effects. All pupae irradiated at or after 48 h developed normally. Conversely, the development to adulthood was delayed in 90% of pupae irradiated at 24h with doses of 750 Gy. However, neither those pupae nor adults that hatched after pupal irradiation at 48 and 72 h displayed morphological changes. Pupae exposed at 48 h of development to 3,000 Gy developed into adults with sharply delimited lesions in the irradiated microplanes of the compound eye or the cuticle of wings and abdomen. CONCLUSIONS: Post-mitotic eukaryotic cells can survive radiation doses of 3,000 Gy largely undamaged, even at the beginning of the terminal morphogenesis. The extremely sharp delimitation between damaged tissue microplanes and adjacent intact tissues may be relevant for future perspectives of radiosurgery.

Animals↗

Physics study of microbeam radiation therapy with PSI-version of Monte Carlo code GEANT as a new computational tool.

Microbeam radiation therapy (MRT) is a currently experimental method of radiotherapy which is mediated by an array of parallel microbeams of synchrotron-wiggler-generated x-rays. Suitably selected, nominally supralethal doses of x-rays delivered to parallel microslices of tumor-bearing tissues in rats can be either palliative or curative while causing little or no serious damage to contiguous normal tissues. Although the pathogenesis of MRT-mediated tumor regression is not understood, as in all radiotherapy such understanding will be based ultimately on our understanding of the relationships among the following three factors: (1) microdosimetry, (2) damage to normal tissues, and (3) therapeutic efficacy. Although physical microdosimetry is feasible, published information on MRT microdosimetry to date is computational. This report describes Monte Carlo-based computational MRT microdosimetry using photon and/or electron scattering and photoionization cross-section data in the 1 eV through 100 GeV range distributed publicly by the U.S. Lawrence Livermore National Laboratory (LLNL) in the 1990s. These are compared with Monte Carlo-based microdosimetric computations using a code and physical data available in the 1980s. With the aim of using the PSI-version of GEANT Monte Carlo code for future macro- and micro/nano-dosimetric studies of Microbeam Radiation Therapy (MRT) a comparison of this code is made with the INHOM(EGS4) (version 1990), Dilmanian-CPE and Persliden-CPE Monte Carlo photon-electron codes (both version 1990) with which the absorbed dose distributions were calculated in 1990 and 1991 considering, (a) a single cylindrical microbeam, (b) multiple cylindrical microbeams in an orthogonal square bundle, and (c) multiple planar microbeams. It is shown that the PSI-version of GEANT can potentially deliver more accurate results (a) using presently the most advanced atomic data, and especially (b) employing "Single-collision" electron transport instead of only the "Condensed-history" electron transport as in code INHOM(EGS4). In contrast Dilmanian-CPE and Persliden-CPE codes deposit the electron energy locally instead of transporting it to the correct position.

Algorithms↗

Low-dose phase contrast x-ray medical imaging.

Phase contrast x-ray imaging is a powerful technique for the detection of low-contrast details in weakly absorbing objects. This method is of possible relevance in the field of diagnostic radiology. In fact, imaging low-contrast details within soft tissue does not give satisfactory results in conventional x-ray absorption radiology, mammography being a typical example. Nevertheless, up to now all applications of the phase contrast technique, carried out on thin samples, have required radiation doses substantially higher than those delivered in conventional radiological examinations. To demonstrate the applicability of the method to mammography we produced phase contrast images of objects a few centimetres thick while delivering radiation doses lower than or comparable to doses needed in standard mammographic examinations (typically approximately 1 mGy mean glandular dose (MGD)). We show images of a custom mammographic phantom and of two specimens of human breast tissue obtained at the SYRMEP bending magnet beamline at Elettra, the Trieste synchrotron radiation facility. The introduction of an intensifier screen enabled us to obtain phase contrast images of these thick samples with radiation doses comparable to those used in mammography. Low absorbing details such as 50 microm thick nylon wires or thin calcium deposits (approximately 50 microm) within breast tissue, invisible with conventional techniques, are detected by means of the proposed method. We also find that the use of a bending magnet radiation source relaxes the previously reported requirements on source size for phase contrast imaging. Finally, the consistency of the results has been checked by theoretical simulations carried out for the purposes of this experiment.

Biopsy↗

Mammography of a phantom and breast tissue with synchrotron radiation and a linear-array silicon detector.

A linear-array, silicon pixel detector, capable of counting single photons, was applied to mammography by using a synchrotron radiation beam. Images were obtained of both a mammographic phantom and a breast-tissue sample. The phantom image was acquired with a mean glandular dose of 0.32 mGy. This detector combined with a synchrotron radiation beam allows acquisition of high-contrast, low-dose images of soft tissues.

Breast↗