PubMed Health⌕ Search

Biomedical subjects

M Dinguizli

Publications and source records attributed to M Dinguizli.

3 recordsLinked to original sources

Characterization of self-assembling copolymers in aqueous solutions using Electron Paramagnetic Resonance and Fluorescence spectroscopy.

Electron Paramagnetic Resonance and fluorescence spectroscopy have been used to determine the micropolarity and microviscosity of self-assembling systems based on mmePEG-p(CL-co-TMC) having different PEG chain lengths and different CL/TMC ratios and PEG/MOG/SA (45/5/50) polymers with different PEG chain lengths. Four reporter probes have been used: two spin probes, 16-doxyl stearic acid and 5-doxylstearic acid, and two fluorescent probes, pyrene and 1,3-bis(1-pyrenyl) propane (P3P). We found that the micelles based on mmePEG-p(CL-co-TMC) polymers are of a biphasic nature. The micelles are made of a hydrophilic corona with low viscosity while the core of the micelle is more hydrophobic and more viscous. The outer shell is made up of PEG chains, the hydrophobic part of the chains making the core. The partial hydration of the shell seems to lead to a looser chain network than that associated with deeper domains in the micelles. By contrast, in micelles composed of PEG/MOG/SA, there is no clear domain separation. This is consistent with a spatial configuration of random polymeric chains forming a loose network. In these micelles, the microviscosity is low and the hydrophobicity is high.

Caproates↗

Development and evaluation of biocompatible films of polytetrafluoroethylene polymers holding lithium phthalocyanine crystals for their use in EPR oximetry.

Electron paramagnetic resonance (EPR) oximetry is a powerful technology that allows the monitoring of oxygenation in tissues. The measurement of tissue oxygenation can be achieved using lithium phthalocyanine (LiPc) crystals as oxygen reporters. In order to have biocompatibility for the sensing system and to assure long-term stability in the responsiveness of the system, we developed films of Teflon AF 2400 with embedded LiPc crystals. These systems can be used as retrievable inserts or parts of an implantable resonator or catheter. Atomic force microscopy studies revealed that the surface of the films was regular and planar. The response to oxygen of the sensor (EPR linewidth as a function of pO(2)) remained unchanged after implantation in mice, and was not affected by sterilization or irradiation. The use of resonators, holding LiPc embedded in Teflon AF 2400, implanted in the gastrocnemius muscle of rabbits allowed the monitoring of oxygen during several weeks. Several assays also demonstrated the biocompatibility of the system: (1) no hemolytic effect was noted; (2) no toxicity was found using the systemic injection test of extracts; (3) histological analysis in rabbit muscle in which the films were implanted for 1 week or 3 months was similar to standard polyethylene biocompatible devices. These advanced oxygen sensors are promising tools for future pre-clinical and clinical developments of EPR oximetry. These developments can be applied for other applications of biosensors where there is a need for oxygen permeable membranes.

Absorption↗