PubMed Health⌕ Search

Biomedical subjects

M Dumontet

Publications and source records attributed to M Dumontet.

11 recordsLinked to original sources

Automated liquid-chromatographic analyzer used for toxicology screening in a general hospital: 12 months' experience.

We evaluated the clinical utility of an automated HPLC system (Remedi, Bio-Rad) for identification of drugs and metabolites in biological fluids. Serum or urine or both from 354 consecutive cases of poisoning were analyzed by the system and by a set of fluorescence polarization immunoassay (FPIA, Abbott) and thin-layer chromatographic (TLC) procedures. Antidepressants and most phenothiazines were recognized by the new system. Comparison of Remedi results with final clinical diagnoses yielded diagnostic specificity and sensitivity of 80% and 90%, respectively. Remedi detected 26 additional compounds that were neither reactive in the immunoassay screening tests nor detected by TLC procedures. Because the Remedi expands the range of drugs covered by the immunoassays and provides a rapid, preliminary report in emergency situations, we conclude that this system can be a useful complementary technique in the clinical toxicology laboratory. Although urine toxicological screening seemed adequate for a good toxicological report, blood analysis allows extra toxicokinetic data such as blood concentrations and half-life estimations.

Chromatography, High Pressure Liquid↗

Rapid, specific and sensitive method for isoniazid determination in serum.

An original simple, specific and rapid high-performance liquid chromatographic assay for the determination of isoniazid (INH) in human serum is presented. The drug was extracted from the serum by protein precipitation with 30% (w/v) trichloroacetic acid, then the drug was reacted with the coupling reagent, trans-cinnamaldehyde, to form a derivative absorbing at 340 nm. A 20-microliters aliquot was injected into the chromatograph after neutralization with 1 M KOH solution. A liquid chromatograph equipped with a reversed-phase 30-microns C18 precolumn linked to a 4-microns C18 analytical column was used. The drug was eluted with a mixture of acetonitrile-water-triethylamine-acetic acid (400:600:2:1, v/v), pH value was 5 +/- 1. Flow-rate and wavelength were set at 1 ml/min and 340 nm, respectively. The extraction recoveries from human serum averaged 100% for INH at concentrations of 1, 2 and 4 mg/l. The coefficients of variation for three different concentrations for INH in serum in the within-day study varied between 1.2 and 3.5%, whereas those in the day-to-day study varied between 2.8 and 4.3%.

Antitubercular Agents↗

[Prevalence of various pneumo-allergens among the positives in global in vitro diagnostic tests for allergy; possible importance of restricted mixtures].

With in vitro utilization of allergenic extracts' mixes, for 67 positive serums to Phadiatop or Allergy Screen, the prevalence of positivity is increased to moulds (6%), grass pollen allergens (34%), ragweed pollen allergens (13%) and tree pollens (12%). Moreover prevalence is 67% to D. pteronyssinus, 7.5% to Cockroaches and 25% to domestic mammals. At least 20% of positive serums are bisensible and 10% polysensible, which leads to do broader testing.

Adolescent↗