PubMed Health⌕ Search

Biomedical subjects

M E Brecher

Publications and source records attributed to M E Brecher.

94 records · Page 6Linked to original sources

Visual identification of bacterially contaminated red cells.

There have been increasing numbers of reports of transfusion-acquired Yersinia enterocolitica bacteremia (including several fatal cases). Fifteen units of whole blood were inoculated with various concentrations of Y. enterocolitica serotype 0:3 and processed into AS-3 preserved red cells (RBCs). Consistent growth of the organism was found at inoculum concentrations greater than or equal to 10 colony-forming units per mL. In all 13 units of RBCs that supported the growth of Y. enterocolitica, a darkening in color (due to hemolysis and a decrease in pO2) was observed in the bag. The attached sample segments, which were sealed from the main unit, remained sterile and did not darken. This color change was apparent in all the contaminated units by Day 35, which was 1.5 to 2 weeks after the bacteria were first detected in cultures of the blood. Hence, by comparison of the color of the segment tubing with that of the unit itself, units grossly contaminated with Y. enterocolitica can be identified prior to transfusion. Moreover, review of photographs on file at the Centers for Disease Control revealed this dramatic color change in 2 units of blood that caused transfusion-transmitted sepsis (Enterobacter agglomerans and an unidentified gram-negative bacillus, not Yersinia sp.), which demonstrated that the color change was not limited to Y. enterocolitica. This method of visual identification of contaminated units of blood could decrease the incidence of posttransfusion bacterial sepsis.

Color↗

False-positive hepatitis B surface antigen screening test results in patients receiving granulocyte-colony-stimulating factor.

BACKGROUND: Granulocyte-colony-stimulating factor (G-CSF) is used for the mobilization of progenitor cells and granulocytes. False-positive hepatitis B surface antigen (HBsAg) enzyme-linked immunosorbent assays (ELISAs) (NML) from one manufacturer in individuals receiving G-CSF have been observed. STUDY DESIGN AND METHODS: Sixty-six autologous peripheral blood progenitor cell donors from 1994 were retrospectively reviewed. Donors typically received 5 to 10 micrograms of G-CSF per kg subcutaneously for 5 days before collection. Additional ELISA dilutional studies (1-in-10, 1-in-100, 1-in-1000) with known HBsAg-negative serum were made with G-CSF. Testing was performed by the University of North Carolina, the American Red Cross in Charlotte, NC, or the National American Red Cross, Washington, DC. RESULTS: Of the 66 patients, none reacted for antibody to hepatitis B core antigen, and 30 (45%) had a positive reaction in the ELISA. Surface antigen positivity was "confirmed" on 6 of the 30 patients by neutralizing ELISA reactivity with an antibody to HBsAg test from the same manufacturer. In all cases, the clinical presentation was not suggestive of hepatitis, and these individuals were not at high risk for hepatitis B. Twenty-seven of the 30 cases were tested with a monoclonal HBsAg ELISA (AUSZYME) from another manufacturer in the peridonation period and did not react. In 1994, 256 autologous whole-blood donors not receiving G-CSF were similarly tested and only 1 (0.4%) had a positive reaction with the second manufacturer's HBsAg ELISA (p < 0.001). Of this group, 41 patients with histories of malignancy were identified, which is comparable to the history of the peripheral blood progenitor cell donors in this study, and none of these blood donors tested positive for HBsAg (p < 0.001). Dilutional studies with G-CSF produced no reactions. CONCLUSION: The NML HBsAg ELISA studied has an unacceptably high false-positive rate in patients or donors receiving G-CSF. The false reactivity of this assay appears to be an indirect consequence of G-CSF administration, which can also lead to spurious confirmation by the HBsAg neutralization assay from the same manufacturer.

Adolescent↗