PubMed Health⌕ Search

Biomedical subjects

M E Dewar

Publications and source records attributed to M E Dewar.

8 recordsLinked to original sources

The effect of design variables of condylar total knees on the joint forces in step climbing based on a computer model.

The ability to climb a steep step or rise from a low chair after total knee replacement may be enhanced if the required force in the quadriceps muscle is reduced. This can potentially be achieved if the total knee produces a large lever arm measured from the femoral-tibial contact point to the patellar ligament. A reduced quadriceps force would also reduce the patello-femoral force and the femoral-tibial contact force. The contact point location is likely to be a function of the geometry of the femoral and tibial components in the sagittal plane, including the relative distal and posterior radii of the femoral profile, the location of the bottom-of-the-dish of the tibial surface, the radius of the tibial surface, and the presence or absence of the posterior cruciate ligament. A three-dimensional model of the knee was developed including the quadriceps and various ligaments. In the study, the motion was confined to flexion extension and displacement in the sagittal plane. The quadriceps was assumed to be the only muscle acting. A standard software package (Pro/Mechanica) was used for the analysis. For a femoral component with a smaller distal radius, there was 12% reduction in the quadriceps muscle force and up to 11% reduction in the patello-femoral force from about 100 up to 60 degrees flexion. However, apart from that, there were less than 10% differences in all the forces as a function of all of the design variables studied. This was attributed to the relatively small changes in the lever arm of the patella tendon, since the tendon moves in an anterior-posterior direction along with the femur. An additional factor explaining the results was the change in the anterior-posterior contact point as controlled by the forces in the patella tendon and in the soft tissues. The results imply that for a standard condylar replacement knee, the muscle and contact forces are not greatly affected by the geometrical design variables.

Biomechanical Phenomena↗

A knee simulating machine for performance evaluation of total knee replacements.

A knee simulating machine is required for the design and evaluation of total knee replacements, the kinematics and the long-term wear being aspects of particular importance. There are no generally agreed design criteria, such that existing designs of simulator have a wide variety of input and constraint conditions. In this study, it was postulated that in order to reproduce physiological wear patterns, the correct kinematics is required, on the basis that the wear will be a direct function of the sliding, rolling and tractive rolling conditions at the joint surfaces. In turn, the correct kinematics would only be achieved by the input of physiological forces, by the appropriate constraints on the fixtures holding the components, and by simulating the soft tissue restraints. A knee simulating machine based on these principles was constructed, and used to test the kinematics of a range of contemporary condylar replacement knees. The displacements and rotations varied over a range of almost two times, even with the soft tissue restraints. Without the restraints, the low constraint designs would have dislocated or moved unrealistically. It was concluded that a simulating machine should be based on the input of forces and moments, rather than on displacements and rotations, in order to provide data of kinematics and wear.

Biomechanical Phenomena↗

Computer-aided socket design for trans-femoral amputees.

Computer-aided socket design (CASD) is a technique for the design of prosthetic sockets using the advantageous features of computer graphics and calculation. This paper describes a computer-aided technique used to design sockets for patients with trans-tibial lower limb amputations.

Amputees↗

Epiphyseal distraction monitored by strain gauges. Results in seven children.

Ten epiphyses in seven children underwent fixed-rate distraction of 0.25 mm twice daily in an attempt to achieve percutaneous leg lengthening by chondrodiatasis. The forces generated across the growth plate were recorded by means of strain gauges incorporated into the distractors. All epiphyses fractured before 33 days of lengthening. An average gain of 6.75 cm was achieved. Epiphyseal distraction at the lower femur produced many complications, but at the upper tibial epiphysis planned lengthening was achieved, with excellent bone production and few complications.

Adolescent↗

Brace treatment of Colles' fracture.

Twenty patients with Colles' fractures were treated with a functional brace that allows wrist motion. The result was compared with a similar group of patients treated with a plaster cast. Dorsal displacement of the fracture was less and wrist function was better in the brace group. Swelling of the hand during the early stages was observed in the brace group; and because this may necessitate brace adjustment, increased medical supervision is necessary for this period.

Adult↗