PubMed Health⌕ Search

Biomedical subjects

M E Huber

Publications and source records attributed to M E Huber.

8 recordsLinked to original sources

Superconducting atomic contacts under microwave irradiation.

We have measured the effect of microwave irradiation on the dc current-voltage characteristics of superconducting atomic contacts. The interaction of the external field with the ac supercurrents leads to replicas of the supercurrent peak, the well-known Shapiro resonances. The observation of supplementary fractional resonances for contacts containing highly transmitting conduction channels reveals their nonsinusoidal current-phase relation. The resonances sit on a background current which is itself deeply modified, as a result of photon-assisted multiple Andreev reflections. The results provide firm support for the full quantum theory of transport between two superconductors based on the concept of Andreev bound states.

Journal Article↗

Limits on spin-independent interactions of weakly interacting massive particles with nucleons from the two-tower run of the cryogenic dark matter search.

We report new results from the Cryogenic Dark Matter Search (CDMS II) at the Soudan Underground Laboratory. Two towers, each consisting of six detectors, were operated for 74.5 live days, giving spectrum-weighted exposures of 34 (12) kg d for the Ge (Si) targets after cuts, averaged over recoil energies 10-100 keV for a weakly interacting massive particle (WIMP) mass of 60 GeV/c2. A blind analysis was conducted, incorporating improved techniques for rejecting surface events. No WIMP signal exceeding expected backgrounds was observed. When combined with our previous results from Soudan, the 90% C.L. upper limit on the spin-independent WIMP-nucleon cross section is 1.6 x 10(-43) cm2 from Ge and 3 x 10(-42) cm2 from Si, for a WIMP mass of 60 GeV/c2. The combined limit from Ge (Si) is a factor of 2.5 (10) lower than our previous results and constrains predictions of supersymmetric models.

Journal Article↗

First results from the Cryogenic Dark Matter Search in the Soudan Underground Laboratory.

We report the first results from a search for weakly interacting massive particles (WIMPs) in the Cryogenic Dark Matter Search experiment at the Soudan Underground Laboratory. Four Ge and two Si detectors were operated for 52.6 live days, providing 19.4 kg d of Ge net exposure after cuts for recoil energies between 10 and 100 keV. A blind analysis was performed using only calibration data to define the energy threshold and selection criteria for nuclear-recoil candidates. Using the standard dark-matter halo and nuclear-physics WIMP model, these data set the world's lowest exclusion limits on the coherent WIMP-nucleon scalar cross section for all WIMP masses above 15 GeV/c2, ruling out a significant range of neutralino supersymmetric models. The minimum of this limit curve at the 90% C.L. is 4 x 10(-43) cm2 at a WIMP mass of 60 GeV/c2.

Journal Article↗

Direct measurement of the Josephson supercurrent in an ultrasmall Josephson junction.

We have measured the supercurrent flowing through a nonhysteretic, ultrasmall, voltage-biased Josephson junction. In contrast with experiments performed so far on hysteretic Josephson junctions, we find a supercurrent peak whose maximum I(s max) increases as the temperature T decreases. The asymptotic T = 0 value of I(s max) agrees with the junction Ambegaokar-Baratoff critical current, as predicted by theory.

Journal Article↗

Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3D k-space reordering.

Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.

Adult↗

Exclusion limits on the WIMP-nucleon cross section from the cryogenic dark matter search.

The Cryogenic Dark Matter Search (CDMS) employs Ge and Si detectors to search for weakly interacting massive particles (WIMPs) via their elastic-scattering interactions with nuclei while discriminating against interactions of background particles. CDMS data, accounting for the neutron background, give limits on the spin-independent WIMP-nucleon elastic-scattering cross section that exclude unexplored parameter space above 10 GeV/c2 WIMP mass and, at >75% C.L., the entire 3sigma allowed region for the WIMP signal reported by the DAMA experiment.

Journal Article↗

Comparison of three methods to recover vancomycin-resistant enterococci (VRE) from perianal and environmental samples collected during a hospital outbreak of VRE.

OBJECTIVE: To establish an efficient and sensitive technique for recovering vancomycin-resistant enterococci (VRE) from perianal and environmental samples collected during implementation of control measures for an outbreak of VRE. DESIGN: Perianal and environmental samples were collected in triplicate on sterile swabs. One swab was used to inoculate a selective broth medium containing 6 pg of vancomycin and 8 pg of ciprofloxacin per mL, one to inoculate Campylobacter agar containing 10 microg/mL of vancomycin, and one to inoculate Enterococcosel agar containing 8 microg/mL of vancomycin. SETTING: Samples were collected in the intensive care units of a 600-bed university hospital over a period of 2 months. SAMPLE SELECTION: Patients and their immediate environment were sampled if they resided in a ward with a patient known to be colonized or infected with VRE. RESULTS: Of the 88 perianal samples obtained from 63 patients, 37 were positive for VRE by broth culture, with 36 also recovered on both types of solid media (sensitivity, 97.3%; negative predictive value, 98.1%). Of the initial samples collected from each of the 63 patients, 20 were positive for VRE by all methods. Of the 500 environmental samples cultured, 139 were positive for VRE in broth, with only 33 recovered on Campylobacter agar (sensitivity, 23.7%; negative predictive value, 77.2%) and 22 on Enterococcosel agar (sensitivity, 15.8%; negative predictive value, 75.2%). CONCLUSIONS: Our data indicate that, when performing surveillance cultures during an outbreak of VRE, use of an enrichment broth medium is required to recover VRE contaminating environmental surfaces; however, direct inoculation to selective solid medium is adequate to recover VRE in patient perianal specimens.

Agar↗

Low-cost MR-compatible moving heart phantom.

For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.

Artifacts↗