PubMed Health⌕ Search

Biomedical subjects

M E Simons

Publications and source records attributed to M E Simons.

16 recordsLinked to original sources

Peripheral vascular malformations: diagnosis and percutaneous management.

Vascular malformations are complex lesions, and their management presents a challenging set of problems. Because VMs are usually treated electively, referral to a centre with a multidisciplinary team approach and with experience diagnosing and treating VMs is recommended. The cornerstone of therapy, embolization, provides both the opportunity for interventional radiologists to become involved in primary patient care and unique challenges that are traditionally not the purview of radiologists.

Angiography↗

Selective arterial embolization for post-traumatic high flow priapism.

We report on a 23 year old patient with high flow priapism following blunt perineal trauma in which arterial-cavernosal fistula was missed by penile Doppler ultrasonography but was successfully localized by arteriography and embolized using Gelfoam pledgets. Detumescence was complete in 2 days and sexual function returned to the premorbid state after 4 weeks. The diagnosis, pathophysiology, and treatment of high flow priapism and review of the literature are discussed.

Adult↗

Exercise-induced asthma. Is gastroesophageal reflux a factor?

An acid-induced cholinergic esophagobronchial reflex has been described whereby acid refluxing into the esophagus causes bronchospasm. Reports of exertional gastroesophageal acid reflux prompted us to study the possibility that exercise-induced asthma (EIA) could be related to gastroesophageal reflux (GER). Following an overnight fast, 10 athletes with a history of EIA (nine men, one woman; mean age 31) were studied. Continuous monitoring of intraesophageal pH and motility, ECG, and arterial oxygen saturation was done. After baseline monitoring at rest for 15 min, subjects underwent treadmill exercise for 10 min followed by continuous monitoring for 30 min after exercise. Spirometry was done at baseline prior to exercise, then repeated every 5 min after exercise for 30 min. Two subjects were retested at a later date following a standard test meal. All 10 subjects demonstrated a decrease in FEV1 in response to exercise, but only half met criteria for EIA. Although 60% (6/10) showed some evidence GER, only three subjects demonstrated a pathologic degree of GER. In the two subjects retested postprandially, change in FEV1 was no different in one and improved in the other despite worsening of GER in both. There was no significant correlations between GER and EIA (P = 0.2). EIA correlated inversely with amplitude of esophageal contractions (P = 0.029) and was directly related to the percentage of multipeaked contractions and the duration of peristaltic contractions (P = 0.08). EIA is not associated with exertional GER.

Adolescent↗

Percutaneous gastrostomy and gastrojejunostomy: additional experience in 519 procedures.

PURPOSE: To assess the efficacy and safety of radiologically guided percutaneous placement of gastrostomy and gastrojejunostomy catheters. MATERIALS AND METHODS: Over 6 years, 562 referred patients were considered for gastrojejunostomy or gastrostomy procedures. In 43 cases (7.7%), the procedure was not performed because of overlying viscera, high position of the stomach, or massive ascites. In 478 patients, 519 procedures were performed. RESULTS: Of 507 attempted gastrojejunostomy procedures, 482 (95.1%) were successful, 14 (2.8%) catheters could not be advanced through the pylorus and necessitated gastrostomies, and 11 (2.2%) were technical failures. Twelve gastrostomy tubes were placed for decompression, with a 100% success rate. Thirty-day follow-up data were available for 457 procedures: The 30-day mortality rate was 17.1% (71 of 416 patients). There were two gastrostomy-related deaths. The overall major and minor complication rates were 1.3% and 2.9%, respectively. CONCLUSION: Percutaneous gastrostomy and gastrojejunostomy are safe and effective methods of providing short- or long-term enteral nutrition or upper gastrointestinal tract decompression.

Catheterization↗

Reliability and validity studies of endoluminal ultrasonography for anorectal disorders.

PURPOSE: Endoluminal ultrasonography (ELUS) is accurate in the assessment of penetration through the rectal wall by carcinoma. Clinical studies were performed to determine the reliability and validity of ELUS. METHODS: The interobserver reliability among four observers with varying experience with ELUS was determined for staging the penetration of rectal cancer through the rectal wall. The ability of ELUS to change the clinical management of the referring clinician (comprehensiveness) was assessed on all referrals over a six-month period. RESULTS: The reliability of ELUS for staging rectal cancer demonstrated only fair to moderate correlation (weighted kappa range, 0.22-0.47). The accuracy of ELUS compared with surgical pathology demonstrated a learning curve proportional to the experience of the observer. In 45 percent of referrals, ELUS changed the clinical management of patients and in 76 percent of referrals the clinician's confidence in the diagnosis and management of patients was altered. ELUS was more likely to change the management of patients with pelvic pouch sepsis (70 percent) and early neoplastic lesions (57 percent) than in more advanced neoplastic lesions (40 percent), perianal Crohn's disease (40 percent), complex noninflammatory bowel disease sepsis (33 percent), and incontinence (31 percent). CONCLUSIONS: ELUS has the ability to change the clinical management of a variety of anorectal conditions. However, for neoplasia the interobserver reliability is only moderate and a learning curve exists.

Adenocarcinoma↗

Effect of surgical sympathectomy on arterial blood flow in reflex sympathetic dystrophy: Doppler US assessment.

PURPOSE: To assess duplex Doppler ultrasound (US) in providing objective, reproducible measurements of blood flow in patients with reflex sympathetic dystrophy (RSD) who underwent surgical sympathectomy. MATERIALS AND METHODS: Findings in eight adult patients with RSD who were evaluated with arterial duplex Doppler US after surgical sympathetectomy were retrospectively reviewed. Pulsatility index (PI) and waveform characteristics were compared to clinical findings (temperature and sudomotor state) in sympathectomized limbs. RESULTS: Warm and dry limbs yielded a consistently low PI (usually less than 2) and biphasic waveform. Cold and clammy limbs, which indicated failed sympathectomy, produced a high PI (usually greater than 4) and triphasic waveform. The Doppler waveform promptly reverted with the return of sympathetic tone in patients who had clinical relapse. CONCLUSION: Duplex Doppler US may be useful for objective follow-up of RSD patients after sympathectomy.

Adult↗

Diagnosis of bleeding mycotic iliac aneurysm on technetium-99m renal scan.

Since abdominal aneurysms are common in the elderly, it is not unusual to see incidental aneurysms on renal scintigraphy performed for other reasons. However, the initial discovery of a bleeding aneurysm on a renal scan in a patient with salmonella septicemia who has no other obvious focus of infection should be considered suspicious for mycotic aneurysm. A prompt diagnosis is crucial to avoid catastrophic outcome associated with delayed surgical intervention.

Aged↗

LGM (Vena Tech) vena cava filter: clinical experience in 64 patients.

LG-Medical (LGM) vena cava filters were inserted percutaneously in 64 patients. Each case was followed after the filter insertion. Clinical follow-up was available in all patients; in 11 patients it was the only form of follow-up. Findings were available from autopsies in seven patients, plain abdominal radiographs in 42, and duplex sonograms of the insertion vein and inferior vena cava (IVC) in 46. A filter was inserted without major complication in all patients. The filter failed to open fully in four patients and was tilted in the IVC in 15. Recurrent pulmonary embolism was found in two patients (fatal in one), and inconsequential filter migration occurred in 11. Introduction vein thrombosis occurred in four patients. IVC thrombosis, demonstrated at autopsy or sonography, was found in 14 patients (22%) and was symptomatic in six (9%). This report suggests that the LGM filter is easy to introduce, and few complications are associated with insertion. The rate of caval thrombosis, however, may be higher than previously reported.

Adult↗

Ultrasound findings in ectopic gestation.

To study the diagnostic accuracy of real-time ultrasonography in the evaluation of ectopic pregnancy, the case records and preoperative sonograms of 57 patients with surgically proven ectopic pregnancy were reviewed. Some 81% of these patients had abnormal sonograms. However, the ultrasonographic findings were often nonspecific and in only 8.7% of the cases was an ectopic fetal heart beat demonstrated. Two patients in this series had coexistent intrauterine and extrauterine gestations. Other findings such as an adnexal mass, an empty uterus, fluid in the cul-de-sac, and a decidual reaction in the uterus are all suggestive of an ectopic pregnancy but can be seen in other conditions. The presence of a normal intrauterine gestation practically rules out the possibility of ectopic pregnancy.

Adnexa Uteri↗

Image-guided insertion of the Uldall tunneled hemodialysis catheter: technical success and clinical follow-up.

PURPOSE: To evaluate the technical success, complication rates, and survival time of the Uldall double-lumen catheter placed by interventional radiologists in patients presenting to a hemodialysis clinic. MATERIALS AND METHODS: Patients eligible for this study included those with end-stage renal disease (ESRD) who had failed peripheral vascular access or who were awaiting access at a hemodialysis unit between June 1993 and March 1996. All catheters were placed under fluoroscopic and ultrasound guidance in the angiography suite. RESULTS: Attempts were made to insert 130 catheters into jugular veins in a consecutive series of 61 patients with ESRD. The accumulated catheter experience in this cohort was 15,380 days and the median survival time was 141 days (95% confidence interval [CI]; 116 days-166 days). One hundred twenty-one catheters (93%) were successfully inserted, mainly (94%) into the internal jugular vein. Excellent dialysis blood flow rate was obtained-on average 365 mL/min (95% CI; 350-379 mL/min). The overall infection rate, including exit site (n = 13), sepsis (n = 19), and clavicular osteomyelitis (n = 1), was 2.1 episodes per 1,000 catheter days. CONCLUSIONS: This catheter is recommended for acute and longer term hemodialysis for patients without peripheral vascular access. It can be inserted percutaneously, the same internal jugular vein can be used repeatedly with few complications and good blood flow, and the technique can be easily learned by any experienced angiographer.

Adult↗

Fluoroscopically-guided manipulation of malfunctioning peritoneal dialysis catheters.

OBJECTIVE: To review our experience with fluoroscopic evaluation and manipulation of malpositioned, malfunctioning, peritoneal dialysis (PD) catheters. MATERIALS AND METHODS: Thirty-one patients, over a 5-year period (1 May 1992 to 30 April 1997) with malfunctioning PD catheters, who had fluoroscopically-guided manipulation were reviewed. Catheters were manipulated using a malleable aluminum bar and, if necessary, guide wires or other stiffeners. Technical success was assessed on the basis of adequate, fluoroscopically verified, catheter placement at the time of the procedure and improved flows. A functional PD catheter at 30 days post manipulation was considered to be a clinically successful manipulation. RESULTS: There were 41 manipulations [33 initial (IM) and 8 remanipulations (RM)] for malpositioned or kinked catheters. In 31 (19 male, 12 female) patients ranging in age from 31 to 76 years (mean age 60 years), the initial technical success rate was 85% for IM (n = 28/33) and 63% (n = 5/8) for RM. The overall clinical success rate, or 30-day primary patency, was 55% for IM (n = 18/33) and 63% for RM. Catheter function (combined IM and RM) continued for a median 869 days (95% CI: 118, 1620). No early complications were noted. CONCLUSIONS: Fluoroscopic manipulation, including attempts at remanipulation, of PD catheters is a safe procedure. The technique is a simple, inexpensive, and effective way of prolonging PD catheter life, thereby reducing the number of surgical interventions.

Adult↗