Electrical defibrillation thresholds with transventricular simple-capacitor discharge under conditions of ischemia by acute coronary occlusion.

The threshold for cardiac defibrillation is defined as that intensity of electrical stimulation that results in a 50% probability of success. Using transventricular simple-capacitor discharge, peak current defibrillatory thresholds were determined under conditions of relative normothermia with ligation of the left descending coronary artery. The average value over 151 successful shocks in 15 dogs was 81.1 mA/g of heart (SD = 29.3). This value was compared by means of the unpaired Student's t-test with the average obtained in a control series, without occlusion, but keeping the same general procedure and experimental conditions (89.5 mA/g, SD = 32.8, 346 defibrillations, 20 dogs). The difference (t = 2.82) was significant at a level P less than 1%. In many cases, there were spontaneous refibrillations after successful discharges, or cardiac arrests which called for mechanical pacing. The latter, in turn, easily led to a new fibrillation, especially when contractility was impaired. When the analysis of variance was applied (Snedecor f-test), we found that the threshold value was stable with respect to time (f = 0.35) during the average experimental period (124 min, SD = 55). We concluded that, on the average, peak current defibrillatory threshold decreased because of myocardial ischemia; however, during the recovery stage, the ventricles showed a high level of instability. Both phenomena (lower threshold and unstable recovery) were probably related to alterations in cellular excitability.

Analysis of Variance↗

Saline and thermal dilution flow measurements: evaluation by means of an open hydraulic model.

A simple open hydraulic model was constructed with the main objective of making comparative evaluations of flow rate measurements, with saline and thermal dilution. In the range of 0.5 to 3.5 l/min, it was found that saline indicator gave a slight underestimation (in the order of 2%) while the thermal indicator showed a minor overestimation of approximately 1%. These values wee taken from the regression equations F (saline) = 0.945 F (real) + 0.0351 and F (thermo) = 1.020 F (real) - 0.0144, both in l/min. Correlations were higher than 0.99 in the two cases. Considering the overall error range, the thermodilution produced a value approximately twice that of saline (-21 to 25% versus -12 to +11%). However, this is not necessarily extendable to living organisms. The model was found useful for test and calibration of detecting cells and for teaching purposes.

Mathematics↗

Effect of body hypothermia on transventricular simple-capacitor-discharge defibrillation thresholds.

In 260 successful transventricular simple capacitor-discharge defibrillations performed on 20 mongrel dogs under conditions of body hypothermia, an overall average peak current threshold of 69.5 mA/g of heart (SD 30.4) was found. This value, when compared by means of the unpaired t test with previous data obtained under conditions of relative normothermia (89.5 mA/g of heart, SD 32.8, 346 defibrillations, 20 dogs) yielded a highly significant difference (P less than 0.1%). When comparing the deviation of the regression equation (current vs. temperature) from the horizontal line, the Snedecor F test gave also a high level of significance (P less than 1%). These results led to the conclusion that body hypothermia significantly reduces transventricular defibrillation thresholds. After normalizing the regression equations, this reduction was found to be on the average equal to 4.1%/degrees C (SD 1.4) for current and to 5.9%/degrees C (SD 1.4) for energy over the 20 dogs. In all animals, the coefficient of variation was greater for energy than for current (about twice as much), suggesting that current is a better descriptor of what is needed for electrical defibrillation. The transventricular impedance was rather constant, yielding an overall average of 28.5 omega (SD 6.0).

Animals↗

[Respirometry by bipolar electric transthoracic impendance].

In a population of ten young normal male subjects (average height of 174.2 cm +/- 3.8, average weight of 70.2 kg +/- 6.16), which was subjectively classified as mainly ectomorph (slightly biased towards the mesomorph type) a good correlation was found between the transthoracic impedance changes due to normal respiratory movements and tidal volume (average r of 0.963 +/- 0.034) and a mean coefficient b1 of 3.64 ohms/liter +/- 1.82. For equal volume, inspiratory and expiratory movements, on the average, produced impedance changes with no significant difference (p less than 0.55). Attempts to quantitatively correlate the coefficient b1 (ohms/liter) with the anthropometric parameters did not produce any consistent result.

Body Constitution↗

[High linearity biologic impedancemeter (author's transl)].

A high linearity instrument for biological use which permits the measurement of impedance modulus and its variations in the range of 50 to 1,000 ohms is described. It has two outputs (Z and delta Z) which can be connected to an oscilloscope or to any conventional physiological recorder. The deviation from linearity is not greater than 0,06%, with a sensitivity of up to 100 mV/ohm, and an estimated average error better than 1% in absolute value with standard deviation better than 3% and an expected range smaller than +/- 10%. The instrument can stand changes of +/- 10% in the a.c. power supply without showing significant alterations in its behavior. Besides, it has good isolating characteristics in order to prevent undesirable leak currents which are potentially dangerous for the patient. The instrument was tested satisfactorily in human beings and in experimental dogs by recording respiratory movements and cardiac activity.

Adult↗