Two-photon fluorescence excitation of macroscopic areas on planar waveguides.

In this paper, we report the first successful demonstration, to our knowledge, of two-photon fluorescence excitation (TPFE) using planar thin-film waveguide structures of macroscopic excitation dimensions (square millimeters to square centimeters in size). The high intensity of excitation light required for TPFE is available not only at a single focus point but along the whole trace of the beam guided in the waveguide structure. Line profiles of the fluorescence excited by TPFE show excellent correlation with the geometry of the launched laser beams. A clear second-order dependence of the fluorescence intensity on the excitation intensity confirms the two-photon character of fluorescence generation. Spectra of the emission generated by one-photon excitation and by two-photon excitation show only minor differences.

Equipment Design↗

Investigation of protein patterns in mammalian cells and culture supernatants by matrix-assisted laser desorption/ionization mass spectrometry.

The direct protein profiling of mammalian cells and bacteria has a growing influence in biotechnology as a high information bearing method for characterization of cells and cell states. Monitoring of proteins excreted in culture media not only serves to produce data on product yield and quality but provides important information on cell viability and nutrient supply that forms the basis for future process and expression optimization. Fast and simple MALDI mass spectrometry approaches were developed to efficiently characterize such complex biological systems. Several mammalian cell lines including CHO DXB11, CHOSSF3, and hybridomas were investigated; the lysis process, the sample pretreatment, and the matrix preparation were optimized for MALDI conditions. Initial experiments to observe the success of protein translation in gene expression experiments were performed. Using MALDI-compatible detergents, it was possible to extend the mass range detectable by MALDI mass spectrometry from the current range of 16,000 to 75,000 Da. In this mass range, the data are complementary (offering a better mass accuracy) to those obtained by SDS-PAGE electrophoresis experiments. These new methods were used to monitor a large-scale cultivation of hybridoma cells expressing an antibody of the IgG type. The increase in whole antibody and antibody light-chain protein, 8650 Da, and the decrease of insulin were followed during the monitoring period. Quantitative measurements of the IgG level during the cultivation compared favorably with those obtained by affinity HPLC.

Animals↗

Preconcentration and separation of antisense oligonucleotides by on-column isotachophoresis and capillary electrophoresis in polymer-filled capillaries.

Small, single-stranded, chemically modified oligonucleotides, complementary to a specific gene section, commonly referred to as antisense compounds, are being investigated as potential therapeutic drugs. A number of modified oligonucleotides, in particular phosphorothioates, are in clinical development. Shorter fragments are found as metabolic products. Isotachophoresis (ITP) allows the introduction of large, diluted sample plugs into the separation capillary. In this work, ITP and capillary electrophoresis (CE) in polymer solutions were successfully coupled in a single capillary in a commercial instrument to increase sensitivity with UV detection and to shorten the time for sample pretreatment. It was shown that ITP-CE can be used as a preconcentration and clean-up method for phosphodiester- and phosphorothioate-containing samples. Up to 3 microL sample could be injected into the capillary without significantly disturbing the separation performance. ITP-CE of phosphodiesters directly out of salt- and protein-containing samples could be demonstrated. For phosphorothioates in serum samples an additional sample clean-up was necessary, due to oligonucleotide-protein binding. An optimized replaceable polymer solution was developed to increase the separation performance for heterogeneous phosphorothioates. A dextran-based sieving medium showed a good separation performance in ITP-CE of phosphorothioates. A concentration detection limit of 8.10(-9) mol/L for the 20-mer phosphorothioate ISIS5132, isolated from rat serum, was found.

Animals↗

Functional immobilization of biomembrane fragments on planar waveguides for the investigation of side-directed ligand binding by surface-confined fluorescence.

A method for the functional immobilization of Na,K-ATPase-rich membrane fragments on planar metal oxide waveguides has been developed. A novel optical technique based on the highly sensitive detection of surface-confined fluorescence in the evanescent field of the waveguide allowed us to investigate the interactions of the immobilized protein with cations and ligands. For specific binding studies, a FITC-Na,K-ATPase was used, which had been labelled covalently within the ATP-binding domain of the protein. Fluorophore labels of the surface-bound enzyme can be selectively excited in the evanescent field. A preserved functional activity of the immobilized enzyme was only found when a phospholipid monolayer was preassembled onto the hydrophobic chip surface to form a gentle, biocompatible interface. In situ atomic force microscopy (AFM) was used to examine and optimize the conditions for the lipid and membrane fragment assembly and the quality of the formed layers. The enzyme's functional activity was tested by selective K+ cation binding, interaction with anti-fluorescein antibody 4-4-20, phosphorylation of the protein and binding of inhibitory ligand ouabain. The comparison with corresponding fluorescence intensity changes found in bulk solution provides information about the side-directed surface binding of the Na,K-ATPase membrane fragments. The affinity constants of K+ ions to the Na,K-ATPase was the same for the immobilized and the non-immobilized enzyme, providing evidence for the highly native environment on the surface. The method for the functional immobilization of membrane fragments on waveguide surfaces will be the basis for future applications in pharmaceutical research where advanced methods for exploring the molecular mechanisms of membrane receptor targets and drug screening are required.

Animals↗

All-solid-state miniaturized fluorescence sensor array for the determination of critical gases and electrolytes in blood.

We describe a six-channel, all-solid-state, miniaturized fluorescence sensor array for the precise determination of blood analytes for medical diagnostic purposes. The device features superblue LEDs as light sources, GRIN optics, and photodiodes, assembled according to pigtailing procedures (Bruno, A. E.; et al. Trends Anal. Chem. 1994, 13, 190-198). The numerical aperture of the fluorescence optics is 0.46, rendering a collection efficiency of 2.4%. The performance of this instrument has been evaluated in terms of dynamic response, linearity, channel reproducibility, reversibility, long-term drifts, photobleaching of indicator, cross-talk, ionic strength, and selectivity in pH measurements. The responses of the pH sensing membranes were optimized in the physiological range. Responses are linear with typical values of approximately 1.5 V/pH units, with limits of decision of 24 mV, which corresponds to pH resolutions of 0.03 pH unit. Under continuous illumination, using calibration buffers, the sensors display nonstatistical differences within 2 standard deviations over a period of 6 h, and it is shown that, under discontinuous illumination, the membranes can be used in more than 2000 measurements without need of calibration, in contrast to electrochemical sensors which require periodic calibration. After selecting the appropriate combination of LEDs, excitation and emission filters, and sensing membranes, the instrument was used to determine the concentrations of various critical blood analytes in buffer solutions in the various channels. Similar measurements in untreated blood reproduce the reported results.

Biosensing Techniques↗

Influence of solvents and detergents on matrix-assisted laser desorption/ionization mass spectrometry measurements of proteins and oligonucleotides.

The effect of solvents was found to be critical for sample preparation in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). For proteins and oligonucleotides the use of 2-propanol/water as a solvent for different matrices can significantly improve the quality of spectra. This effect is demonstrated with proteins ranging in molecular weight from 12 to 150 kDa and with a special 19-mer oligonucleotide. A comparison of MALDI-MS using of 2-propanol as matrix solvent and high-performance capillary electrophoresis resulted in identical relative peak intensities for a p(dT)12-18 oligonucleotide mixture. Additionally, the effect of detergents for characterization of high molecular weight proteins in very dilute solutions was studied with this solvent. It was found that Triton X-100, up to a concentration of 1%, was highly compatible with MALDI measurements and even could improve the quality of spectra. Use of detergents for cell profiling has extended the detectable mass range to about m/z 75,000.

1-Propanol↗

Analysis of drug/plasma protein interactions by means of asymmetrical flow field-flow fractionation.

PURPOSE: The applicability of Asymmetrical Flow Field-Flow Fractionation (Asymmetrical Flow FFF) as an alternative tool to examine the distribution of a lipophilic drug (N-Benzoyl-staurosporine) within human plasma protein fractions was investigated with respect to high separation speed and loss of material on surfaces due to adsorption. METHODS: Field-Flow Fractionation is defined as a group of pseudochromatographic separation methods, where compounds are separated under the influence of an externally applied force based on differences in their physicochemical properties. This method was used to separate human plasma in its protein fractions. The drug distribution in the fractions was investigated by monitoring the fractionated eluate for drug content by fluorescence spectroscopy. RESULTS: Human plasma was separated into human serum albumin (HSA), high density lipoprotein (HDL), alpha 2-macroglobulin and low density lipoprotein (LDL) fractions in less than ten minutes. Calibration of the system and identification of the individual fractions was performed using commercially available protein reference standards. The influence of membrane type and carrier solution composition on the absolute recovery of N-Benzoyl-staurosporine and fluorescein-isothiocyanate-albumin (FITC-albumin) was found to be quite significant. Both factors were optimized during the course of the investigations. N-Benzoyl-staurosporine was found to be enriched in the fraction containing HSA. CONCLUSIONS: If experimental conditions are thoroughly selected and controlled to suppress drug and plasma protein adsorption at the separation membrane, Asymmetrical Flow FFF shows high recoveries and fast separation of human plasma proteins, and can be a reliable tool to characterize drug/plasma protein interactions. For analytical purposes it has the potential to rival established technologies like ultracentrifugation in terms of ease-of-use, precision, and separation time.

Adsorption↗

Fiber-optic evanescent wave biosensor for the detection of oligonucleotides.

An automated optical biosensor system based on fluorescence excitation and detection in the evanescent field of a quartz fiber was used to detect 16-mer oligonucleotides in DNA hybridization assays. A biotinylated capture probe was immobilized on the fiber surface via avidin or streptavidin. The hybridization with fluorescein-labeled complementary strands was monitored in real time by fluorescence detection. The double strands formed by hybridization could be dissociated by chemical or thermal regeneration, allowing one to perform hundreds of assay cycles with the same fiber. The signal loss during longtime measurements, i.e., consecutive hybridization assays, can be described by a single-exponential function. Over more than 200 cycles, the net signal decreased by 50% with a signal variation of 2.4% after correction for this signal loss. By binding the capture probe with the 5'-end to the optical fiber surface, and by using a 50% (w/w) aqueous urea solution for chemical regeneration, the duration of an assay cycle could be reduced to 3 min. By applying longer assay cycles, the detection limit for the hybridization with a complementary fluorescein-labeled oligonucleotide was 2.0 x 10(-13) M (24 fmol). To detect an unlabeled complementary 16-mer oligonucleotide, competitive hybridization assays were performed, resulting in a detection limit of 1.1 x 10(-9) M (132 pmol). Poly-(acrylic acid) 5100 sodium salt and Tween 20 were used in the hybridization buffer to prevent nonspecific binding caused by ionic or hydrophobic interaction. The amount of nonspecific binding of noncomplementary oligonucleotides was in the range of 1-2%, compared with the specific binding in the different hybridization assays.

Base Sequence↗

Immunoassays in monitoring biotechnological drugs.

For the evaluation and interpretation of pharmacokinetic data reliable quantitative determinations are a requirement that can only be met by well-characterized and fully validated analytical methods. To cope with these requirements a method is being established that is based on an integrated and automated fiber-optic biospecific interaction analysis system (FOBIA) for immunoassays. Performance characteristics of this system used in monitoring of recombinant hirudin (CGP 39 393) are presented. Recombinant hirudin is a highly potent and selective inhibitor of human thrombin. Owing to its size and charge, recombinant hirudin is mainly eliminated by glomerular filtration. But only a fraction of the hirudin dose seems to be reabsorbed at the proximal tubule by luminal endocytosis and hydrolyzed by lysosomal enzymes, leaving approximately 50% of the dose to be extracted in the urine. Thus, renal clearance of recombinant hirudin in the absence of renal insufficiency appears to depend primarily on the glomerular filtration rate. During a 3-month i.v. tolerability study in dogs, some of the dogs developed antibodies against recombinant hirudin. The hirudin-antibody complex accumulated in plasma and apparent hirudin plasma concentrations were therefore much higher than expected from single-dose kinetics. Hirudin captured by antibodies showed an extended half-life and the hirudin-antibody complex is still pharmacologically active, as demonstrated by the observed increase in thrombin time. In conclusion, only appropriate analytical methods allow adequate monitoring and pharmacokinetic characterization of biotechnology drugs in biological materials.

Animals↗

Reliability of assessing patellar alignment: the A angle.

Anterior knee pain syndrome is a complex problem for clinicians and patients. One possible etiological factor that has been identified is malalignment of the patella. Recently, a clinical method to assess patellar malalignment has been proposed--the A angle. However, no reliability of this technique was reported. Therefore, the purpose of this study was to determine intrarater and interrater reliability for the A angle. Thirty-six subjects participated in this study. Three raters measured each knee twice (N = 70). Interclass correlation coefficients (ICC) and standard error of measurements (SEM) were determined for the A angle and component measurements. Intrarater A-angle values ranged from 11.8 to 23.5 degrees. Intrarater A-angle ICCs were poor (0.20-0.32, SEM = 5.30-7.95 degrees). Interrater A-angle ICC was poor (-0.01, SEM = 7.82 degrees). Results indicated that the A angle as determined in this study was not reproducible. Therefore, further study is needed before the A angle can be used as a reliable assessment tool for patellar position.

Adult↗

Characterization of yeast cultivations by steric sedimentation field-flow fractionation.

The characterization and quantification of biomass is often time consuming and dependent on the cultivation media and gives no detailed information between cell size and shape and their productivity. By monitoring the bioprocess with steric sedimentation field-flow fractionation (Sd/StFFF) in combination with laser light scattering, not only cell growth, but also the variation of cell size and shape during the cultivation, can be observed. In this work, the feasibility of separating and characterizing cell populations by steric sedimentation field-flow fractionation is demonstrated by its application to three different yeast cultivation broths. For this purpose samples which were collected at different cultivation times were injected into an FFF system. Fractograms were obtained in less than 4 min. Due to the relatively high resolution of the method, a cell sample could be fractionated in several subpopulations differing in their size as well as in their number of buds.

Cell Separation↗

Chromatographic enzyme immunoassay for T-2 toxin.

Both the active ester and maleimide moieties of the cross-linking reagent, N-[(gamma-maleimidobutyryl)oxy]succinimide (GMBS), were found to react with the primary amino groups on ribonuclease (RNase). This largely inactivated RNase towards a polymeric (but not monomeric) substrate. Citraconylating the RNase first, so that essentially only a single primary amino group remained to react with GMBS, overcame this problem. The subsequent maleimido-citraconyl-RNase was used to prepare a 1:1.1 M conjugate of anti-T-2 toxin Fab' and RNase (Fab'-RNase) in a 76% yield. The conjugate was used to detect as little as 0.1 microgram of T-2 toxin based on the ability of T-2 toxin to specifically displace Fab'-RNase complexed to a T-2 agarose affinity gel.

Chromatography↗

Tresyl activation of a hydroxyalkyl ligand for coupling to a hydrazide gel: stable immobilization of T-2 toxin for affinity purification of T-2 antibody.

A stable T-2 hydrazide gel is prepared by activating T-2 toxin with tresyl chloride followed by coupling to agarose-adipic acid hydrazide. Utilized as an affinity chromatography column, this T-2 hydrazide gel purifies a monoclonal antibody for T-2 in high yield directly from ascites fluid. Specific antibody trapped on the column is eluted either with excess T-2 or at pH 11.6. Much less successful are two other T-2 affinity columns that were prepared and evaluated: T-2 bovine serum albumin Affi-Gel 15 and T-2 hexylamine Sepharose.

Antibodies↗

Substrate-leash amplification with ribonuclease S-peptide and S-protein.

The S-peptide and S-protein fragments of ribonuclease S (RNase S, no EC no. assigned) have been immobilized onto separate Sepharose gels via a "leash" of polycytidylic acid substrate. Each of these gels releases its RNase fragment when treated with the complementary enzyme fragment or with RNase A (EC 3.1.27.5), and the released fragments recombine to give RNase S activity. Thus this system provides substrate-leash amplification (SLA), such that more enzymatic activity is eluted from the system than is applied. For example, 100 pg of RNase applied to the S-peptide gel is amplified by 1.9 X 10(4) to the equivalent of 1.9 micrograms of activity in 20 h, when followed by combination of the released S-peptide with excess S-protein. We also tested a three-stage amplification system, with a pair of S-peptide and S-protein gels at each stage. In this system the cumulative amplification of the initial 1-ng dose of RNase A is 4.9, 52, and 25-fold after each stage, respectively. Only 2 mg of each SLA gel is used per stage in these experiments, reflecting the magnitude of their production of RNase S activity.

Animals↗

Neonucleoproteins. Preparation and high-performance liquid chromatographic characterization of succinyl-lysozyme-diaminooctyl-polycytidylic acid and related polycytidylic acid conjugates.

Transamination conjugates of cytidine-3'-phosphate and polycytidylic acid (poly C) with diaminopropane, diaminohexane and diaminooctane (DAO) are formed both at 25 degrees C and 60 degrees C. The extent of reaction and formation of side products, with intermittent hydrolysis to mononucleotides in the case of aminoalkyl-poly C, is monitored by reversed-phase high-performance liquid chromatography. Both Dns-DAO-poly C and succinyl-lysozyme-DAO-poly C covalent conjugates are then prepared and similarly characterized, including separation on a size-exclusion diol high-performance liquid chromatography column. The retention of the latter on a wide-pore reversed-phase column seems to be controlled by the protein moiety.

Chemical Phenomena↗