PubMed Health⌕ Search

Biomedical subjects

M Escobar-Gomez

Publications and source records attributed to M Escobar-Gomez.

At least 19 recordsLinked to original sources

[Complication profiles of posterior chamber intraocular lenses IOL). An analysis of 586 foldable and 2077 rigid explanted intraocular lenses].

BACKGROUND: Foldable intraocular lenses (IOL) have become increasingly preferred choice for IOL implantation after cataract removal. However, both foldable as well as rigid IOLs are not yet complication-free and may need explanation. MATERIAL AND METHODS: A total of 2663 explanted posterior chamber IOLs (PCIOLs) were accessioned at the Center for Research on Ocular Therapeutics and Biodevices between January 1988 and September 2000. The lenses were examined grossly using a Leitz/Wild M-8-Zoom stereomicroscope. The clinical reasons for explanation were documented for foldable as well as for rigid lenses. RESULTS: Of a total of 2663 explanted PCIOLs, 586 were foldable lenses and 2077 were rigid PMMA lenses The most frequent reason for explantation of all 2663 IOLs studied was decentration/dislocation. Optic and haptic damage and posterior capsule rupture were significantly more often a reason for explantation in several foldable designs compared to rigid PCIOLs. Whereas rigid designs lead more often to corneal decompensation. The percentage of explanted IOLs because of inflammatory reactions decreased significantly from 1994 to 2000. CONCLUSIONS: The complication profiles of rigid and foldable IOLs revealed some apparent differences due to the nature of the IOL biomaterials and designs. IOL optic/haptic damage was a common complication for foldable IOLs, whereas it was only discovered in single digits for rigid PMMA IOLs. The possible explanation for this is, that the soft and flexible biomaterials, from which all the foldable IOLs were manufactured, are easier to be damaged during folding, unfolding and insertion procedure. In our opinion this relative disadvantage of foldable IOLs is by far outweighed by the numerous advantages of the small incision cataract surgery. The decreasing inflammatory reactions can be explained by advances in surgical techniques, especially the secure in-the-bag fixation of IOLs.

Humans↗

[Morphological autopsy findings in human eyes implanted with Ridley intraocular lenses].

BACKGROUND: Sir Harold Ridley's first cataract extraction with implantation of an intraocular lens (IOL) marked the beginning of a major change in the practice of ophthalmology. MATERIAL AND METHODS: Two human autopsy globes implanted with original Ridley IOLs were grossly examined from behind with the Miyake-Apple photographic technique. The anterior segments were evaluated histologically. One Ridley IOL was examined by scanning electron microscopy. RESULTS: Both IOLs maintained a clear visual axis and had been placed in the capsular sac. The right lens was decentered inferiorly, the left IOL was well centered. The posterior capsule showed only minimal capsular opacification. Scanning electron microscopy (SEM) of the explanted IOL showed a smooth, well polished surface. CONCLUSIONS: In this patient Ridley IOLs maintained an ideal visual rehabilitation of 20/20 in both eyes, 22 and 18 years postoperatively. One surprising finding was the presence of a square, truncated optic edge geometry, very similar to that seen in some modern foldable IOLs. In our opinion the absence of posterior capsule opacification of the Ridley IOL may have partially been a result of this nearly sharp optic edge, that we confirmed by SEM. Even 22 years after implantation the Ridley IOL showed a high finish quality. Many of Sir Harold Ridley's early concepts like the IOL placement in the posterior chamber and endocapsular implantation are now the standard of modern cataract surgery.

Aged↗

Eradication of posterior capsule opacification: documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem.

OBJECTIVE: (1) To report the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy rate (%) of eight rigid and foldable intraocular lens (IOL) designs in a series of 5416 pseudophakic human eyes obtained postmortem, accessioned in our center between January 1988 and January 2000. (2) To identify factors that are instrumental in reducing the incidence of posterior capsule opacification, (PCO, secondary cataract) and hence the need for Nd:YAG laser posterior capsulotomy. DESIGN: Comparative autopsy tissue analysis. PARTICIPANTS: A total of 5416 globes with posterior chamber intraocular lens (PC-IOLs) obtained postmortem received from Lions Eye Banks between 1988 and 2000. METHODS: Miyake-Apple posterior photographic technique. Special reference was given to the presence or absence of Nd:YAG laser posterior capsulotomy orifice on the posterior capsule of each eye. MAIN OUTCOME MEASURES: The Nd:YAG laser posterior capsulotomy rate (%) as of January 2000 was documented. In addition, the Nd:YAG laser posterior capsulotomy rate for each lens was plotted on a monthly basis for the same period, creating a computerized trend or "timeline" for each IOL style. RESULTS: Relatively high Nd:YAG laser posterior capsulotomy rates ranging from 20.3% to 33.4% were noted with four relatively older designs (high incidence of implantation between 1988 and the early 1990s). Four modern foldable IOLs manufactured from silicone and acrylic materials had significantly lower Nd:YAG laser posterior capsulotomy rates ranging from 0.9% (Alcon Acrysof) to 17.1%. The difference in Nd:YAG rates among the eight IOL designs was found to be significant (P < 0.0001, chi-square test). Comparing foldable versus rigid designs, the foldable IOLs were associated with a much lower Nd:YAG laser posterior capsulotomy rate (14.1% vs. 31.1%). CONCLUSIONS: By use of the six factors regarding surgical technique and IOL choice described in this article, we strongly believe that the overall incidence of PCO and hence the incidence of Nd:YAG laser posterior capsulotomy is now rapidly decreasing from rates as high as 50% in the 1980s to early 1990s. Surgical tools and IOLs are now available to bring these rates down to single digits. Careful application and use of these tools by surgeons can genuinely lead in the direction of virtual eradication of secondary cataract, the second most common cause of visual loss worldwide.

Cataract↗

Anterior capsule opacification: correlation of pathologic findings with clinical sequelae.

OBJECTIVE: To evaluate the degree of anterior capsule opacification (ACO) in human eyes obtained postmortem containing various rigid and foldable posterior chamber intraocular lens (PC-IOL) designs and compare the findings with clinical sequelae of capsular shrinkage. DESIGN: Comparative autopsy tissue study with clinicopathologic correlations. MATERIALS: Three hundred formalin-fixed human eyes containing the following PC-IOL styles were analyzed: (1) one-piece polymethyl methacrylate (PMMA) optic-PMMA haptic (n = 50), one-piece silicone-plate IOL, with large (2) or small (3) fixation holes (n = 35), (4) three-piece PMMA optic-Prolene haptic (n = 50), (5) three-piece acrylic optic-PMMA haptic (n = 55), three-piece silicone optic with PMMA (6) or polyimide (7) haptics (n = 30), and (8) three-piece silicone optic-Prolene haptic (n = 80) lenses. TESTING: The eyes were sectioned in the equatorial plane for gross examination of the capsular bag from a posterior view. The cornea and iris were then excised for evaluation from an anterior view. MAIN OUTCOME MEASURES: ACO was scored in each eye from 0 to IV, according to the degree/area of capsule opacification. Capsulorrhexis size and IOL decentration were measured with calipers. RESULTS: The overall differences among the IOL groups regarding the three parameters were significant (ACO score: P < 0.001; capsulorrhexis diameter: P = 0.036; IOL decentration: P = 0.012). Mean ACO scores were highest with the large- and small-hole one-piece silicone-plate lenses (2.543 +/- 0.950) and lowest with the three-piece acrylic optic-PMMA haptic lenses (0.600 +/- 0.710). Of 10 cases of capsulorrhexis phimosis observed in the study, 7 cases were associated with three-piece silicone optic-Prolene haptic lenses, which also presented the highest mean decentration (0.375 +/- 0.601 mm). CONCLUSIONS: Our results confirm previous histopathologic observations that the rate of ACO is the lowest with acrylic lenses and higher with plate-haptic silicone IOLs. Nevertheless, clinical sequelae of capsular shrinkage are also very important with three-piece silicone optic-Prolene haptic designs. Thus, IOL material and design are significant factors in the development of ACO, but they ultimately also influence the clinical presentation of capsular shrinkage.

Acrylic Resins↗

Effect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses.

PURPOSE: To evaluate surface properties of various intraocular lenses (IOLs), including a newly fabricated heparin-surface-modified (HSM) silicone IOL, with special reference to their efficiency in reducing potential silicone oil adherence to the IOL optics. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Five groups of rigid and foldable IOLs were analyzed in an in vitro test for the percentage of silicone oil adherence: a single-piece foldable hydrophilic-acrylic IOL (n = 9); a single-piece rigid poly(methyl methacrylate) (PMMA) IOL with HSM coating of the lens optic (n = 9); a 3-piece foldable silicone optic IOL with HSM coating of the optic (n = 10); a single-piece standard rigid PMMA IOL (n = 7); and a standard 3-piece foldable silicone optic IOL (n = 9). After the IOLs were immersed in water and then in silicone oil, gross photographs taken. Image analysis was performed to evaluate the percentage of silicone oil coverage of the anterior and posterior surfaces of each IOL optic. RESULTS: The mean silicone oil coverage of the hydrophilic-acrylic IOLs was 5.6% +/- 2.5% (SD); of the HSM PMMA IOLs, 6.2% +/- 4.3%; of the HSM silicone optic IOLs, 6.7% +/- 3.2%; and of the standard PMMA IOLs, 20.3% +/- 13.3%. The mean silicone oil coverage was greatest on the standard silicone optic IOLs, 98.2% +/- 3.1%. CONCLUSIONS: Intraocular lenses with a hydrophilic optic have less tendency toward adherence to silicone oil than more hydrophobic designs. A foldable silicone IOL with heparin surface modification can significantly reduce potential silicone oil adherence, comparable to the level achievable with the rigid HSM PMMA designs. Two new foldable IOL styles, the HSM silicone IOL and IOLs in the general class of hydrophilic-acrylic, were highly efficacious in reducing silicone oil adherence. There is now a real choice of foldable lenses for patients with actual or potential vitreoretinal diseases.

Acrylic Resins↗

[Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem].

BACKGROUND: The purpose of this study was to analyze any possible surgical reasons which may have had caused posterior capsule opacification in 3-piece silicone IOLs that had required Nd:YAG laser treatment. Special attention was given to 1) quality of cortical clean up, 2) type of haptic fixation, and 3) continuous curvilinear capsulorhexis (CCC) size and shape. MATERIALS AND METHODS: Human eyes obtained post-mortem implanted with 3-piece silicone optic - PMMA haptic (SI 40 NB) and 3-piece silicone optic - Prolene haptic (SI 30 NB) designs IOLs, accessioned between January 1993 and December 2000 were evaluated by gross examination from behind under an operating microscope using the Miyake-Apple posterior photographic technique. The area and intensity of Soemmerring's ring and type of fixation was studied in 457 eyes. The mean diameter of the CCC and relation of the CCC edge to the optic rim were analyzed in 221 eyes. RESULTS: 1) The amount of Soemmerring's ring formation was significantly larger in the group of IOLs requiring Nd:YAG capsulotomy in both the SI 40 NB and SI 30 NB design than in the IOLs without capsulotomies. 2) The percentage of not in-the-bag fixated IOLs in both the SI 40 NB and SI 30 NB design was larger in the "Nd:YAG groups", without being statistically significant. 3) The "Nd:YAG groups" showed a significant higher amount of non overlapping clock hours of the CCC edge in relation to the optic rim. CONCLUSION: 1) The data confirm the clinical assumption that the incidence of PCO is correlated with the cortical clean up. 2) Our findings also support the clinical assumption, that poor IOL fixation increases the risk of PCO. 3) This study also verifies the relation of the CCC to PCO, namely a relatively small CCC covering the entire optic rim is best to reduce the Nd:YAG laser rate.

Cataract↗

[Postoperative opacification of posterior chamber intraocular lenses - a review].

Postoperative opacification of intraocular lenses (IOLs) is a very unpleasant complication for the ophthalmic surgeon and the patient. We report on our experiences with opacification of different foldable IOL designs and rigid poly (methyl methacrylate) (PMMA) posterior chamber lenses.1. Snowflake degeneration of PMMA IOLs: This condition is an unanticipated and surprising late postoperative finding 8 to 15 years after implantation. In our opinion, this complication is probably not related to the PMMA biomaterial itself, but rather it appears to represent a manufacturing problem that has affected a selected, albeit large number of lenses manufactured in the 1980s-mid 1990s.2. Degeneration of UV absorber material and calcium deposits within the optic of hydrophilic IOLs: Two years postoperatively degenerations of UV absorber material and calcium deposits within the optic of single piece hydrophilic acrylic lenses SC60B-OUV manufactured by MDR (Medical developmental research Inc. Clearwater FL, USA) can occur. Although the precise mechanism is not fully known, it was assumed that these opacifications are due to premature aging of the UV blocking agent incorporated in the lens biomaterial and calcification.3. Calcification on the surface of the Bausch & Lomb Hydroviewtrade mark IOLs: Twelve to 15 months postoperatively granular surface calcifications in Hydroviewtrade mark IOLs occured. The mechanism is not fully understood. According to Bausch and Lomb studies, part of the components of the packaging contained silicone, which may have come off the packaging onto the lens optic, where it then appears to be a catalyst for calcium precipitation. The manufacturer has correlated a change in packaging with the appearance of the opacification. The manufacturer now believes that this problem has been solved. However, final verification will require a careful 1 - 2 years clinical study.4. Glistenings in the hydrophobic acrylic AcrySoftrade mark IOLs: The time frame of glistenings in the AcrySoftrade mark IOLs is highly variable. It has been suggested that the occurrence of glistenings may be related to variations in the temperature of the lens just prior to and or during insertion into the eye. Formation of vacuoles may occur within the submersed acrylic polymer when there is a transient increase and then decrease in temperature during the surgical procedure. "Glistenings" may then subsequently form by ingress of anterior chamber fluid. Contrast sensitivity can been decreased in some patients, but clinically significant decrease of visual acuity has been rare.

Biocompatible Materials↗

[Millenniums update on posterior capsule opacification (PCO) scores, centration, biocompatibility and fixation of foldable intraocular lenses (IOL) - an analysis of 1,221 pseudophakic post mortem globes].

BACKGROUND: The ongoing and fast evolution of foldable IOL designs established the necessity to evaluate the different abilities of each lens style. The large IOL database (over 16,500 specimens) acquired in our laboratory, has permitted us to perform a clinico-pathological analysis on pseudophakic autopsy globes provided from sources worldwide, especially many Lions Eye banks in the United States. MATERIAL AND METHODS: We analyzed 6 foldable IOL styles commonly implanted in the United States, using one type of rigid IOL design (1-piece design rigid PMMA optics) as a comparison group. Posterior capsule opacification (PCO) score, decentration, fixation, presence or absence of a Nd:YAG laser posterior capsulotomy and area and intensity of Soemmerring's ring formation was discerned by examination under an operating microscope using the Miyake-Apple posterior photographic technique. RESULTS: The four lenses with the lowest rates ranging between 3.8 % and 21.7 % are modern designs, mostly implanted after 1992. The two lenses with the higher rates ranging between 23.1 % and 30.4 %, were all older designs, already prevalent prior to 1992. IOL fixation with both haptics in the capsular bag showed the best centration values and PCO scores. Our studies to date have shown in a preliminary fashion that the AcrySoftrade mark IOL displays the the lowest (best) biocompatibility score. CONCLUSIONS: Entering the new millenium, with evolution of modern surgical techniques and IOL designs, the incidence of the two major complications of cataract surgery, decentration and PCO are now finally diminishing.

Autopsy↗

Postoperative deposition of calcium on the surfaces of a hydrogel intraocular lens.

OBJECTIVE: To report clinical, pathological and histochemical features of 5 Hydroview intraocular lenses (IOLs) explanted from five patients who had visual disturbances caused by postoperative deposits on the lens surfaces. DESIGN: Noncomparative small case series with clinicopathologic and histochemical correlations. PARTICIPANTS: Five hydrophilic IOLs explanted from five different patients. All patients presented with decreased visual acuity and glare circa 12 months after uneventful phacoemulsification and IOL implantation, associated with a red-brown granularity on the optical surfaces of the IOLs. METHODS: The lenses were explanted, fixed in buffered formaldehyde and examined by gross and light microscopy. MAIN OUTCOME MEASURES: Staining of the IOLs with 1% alizarin red and with the von Kossa method (both stains for calcium). Two additional IOLs were also stained and included as controls. RESULTS: The optical surfaces of all five IOLs were covered by a layer of irregular granular deposits, composed of multiple fine, translucent spherical-ovoid granules. The deposits stained positive for calcium in all cases. No deposit or positive staining was observed on the IOLs haptics. Staining of the control IOLs was also negative. CONCLUSION: This is the first histopathological report of calcified deposits on the surfaces of this hydrogel IOL model. Further studies on other similar cases with this lens should be done to determine the incidence and possible mechanisms of this phenomenon.

Aged↗

Anterior capsule opacification: a histopathological study comparing different IOL styles.

OBJECTIVE: To compare the degree of anterior capsule opacification (ACO) in human eyes obtained post-mortem containing various rigid and foldable posterior chamber intraocular lens (PC-IOL) designs. DESIGN: Comparative autopsy tissue study with clinicopathologic correlations. MATERIALS: Four hundred sixty human globes containing the following PC-IOL styles were analyzed: (1) one-piece polymethylmethacrylate (PMMA) optic-PMMA haptic (n = 50), (2) one-piece silicone-plate IOL, large hole (n = 40), (3) one-piece silicone-plate IOL, small hole (n = 67), (4) three-piece PMMA optic-PMMA/Prolene haptic (n = 51), (5) three-piece acrylic optic-PMMA haptic (n = 96), (6) three-piece silicone optic-PMMA haptic (n = 24), (7) three-piece silicone optic-polyimide haptic (n = 40), and (8) three-piece silicone optic-prolene haptic (n = 92). TESTING: The globes were sectioned in the equatorial plane for gross examination and then processed through paraffin; sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome stains; and examined by light microscopy. MAIN OUTCOME MEASURES: Anterior capsule opacification was scored in each eye by grading the histologic sections from 0 to III, according to the amount (thickness) of proliferative tissue and cells measured in sagittal sections on the inner surface of the anterior capsule at the capsulorhexis margin. RESULTS: The difference among the eight groups was significant (P < 0.0001). Mean ACO scores were highest with the large and small hole one-piece silicone-plate lenses (1.77 +/- 0.86 and 1.28 +/- 0.77, respectively). The lowest mean score was observed in the group of three-piece acrylic optic-PMMA haptics lenses (0.51 +/- 0.52). CONCLUSIONS: Our results confirm previous clinical observations that the rate of ACO is relatively high with plate-haptic silicone IOLs. The lowest rate was noted with the three-piece acrylic optic-PMMA haptic IOL. The IOL design and IOL material are significant factors in the development of ACO.

Cataract↗

Dye-enhanced cataract surgery. Part 1: anterior capsule staining for capsulorhexis in advanced/white cataract.

PURPOSE: To evaluate anterior capsule staining using 3 dyes to perform continuous curvilinear capsulorhexis (CCC) in postmortem human eyes with advanced/white cataract. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: In experimental closed-system surgery, CCC was performed in 12 postmortem human eyes with cataract after the anterior capsule was stained with 3 capsule dyes (fluorescein sodium 2%, indocyanine green [ICG] 0.5%, and trypan blue 0.1%). Two commonly used techniques for capsule staining were also compared: staining within an air bubble and intracameral subcapsular injection of dye. RESULTS: In all globes, CCC was uneventful using the 3 dyes and with both techniques. With the intracameral subcapsular injection, the dye remained trapped in the subcapsular space in contact with the posterior surface of the anterior capsule, allowing enough time to perform any maneuver. The staining provided by ICG, at the concentration used, was slightly superior to that of the other dyes. Leakage of fluorescein sodium into the vitreous cavity was seen using the Miyake-Apple posterior video/photographic technique. CONCLUSION: Intracameral subcapsular injection of ICG allowed the easiest recognition of the capsular flap by staining the posterior surface of the anterior capsule and without leaking into the vitreous cavity.

Cadaver↗

Dye-enhanced cataract surgery. Part 3: posterior capsule staining to learn posterior continuous curvilinear capsulorhexis.

PURPOSE: To evaluate the use of 2 dyes for staining the posterior capsule to enhance visualization during posterior continuous curvilinear capsulorhexis (PCCC). SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Indocyanine green 0.5% (ICG) and trypan blue 0.1% were used to stain the posterior capsule for performing PCCC in 8 human eyes obtained postmortem. The eyes were prepared according to the posterior video technique of Miyake-Apple. After CCC and hydrodissection/delineation were performed, the nucleus was carefully delivered by hydroexpression. Cortical cleanup was completed by irrigation/aspiration. The posterior capsule was stained by instilling 1 microdrop of ICG (4 eyes) or trypan blue (4 eyes) in the capsular bag. A PCCC was then performed by 2 independent surgeons (4 eyes/surgeon) not familiar with this technique. Each surgeon also performed PCCC in 2 eyes without the use of dye. RESULTS: Both dyes facilitated the performance of PCCC after staining the otherwise transparent posterior capsule. It was easier to differentiate the stained posterior capsule flap from the underlying transparent anterior hyaloid phase of the vitreous. In addition, optic capture of an intraocular lens, with or without anterior vitrectomy, was easily accomplished because of the enhanced visualization by posterior capsule staining. CONCLUSIONS: Posterior capsule staining can be successfully used to learn and perform the PCCC procedure, combined with optic capture, anterior vitrectomy, or both.

Cadaver↗