PubMed Health⌕ Search

Biomedical subjects

M Essig

Publications and source records attributed to M Essig.

At least 109 records · Page 6Linked to original sources

[Invasive cervix carcinoma (pT2b-pT4a). Value of conventional and pharmacokinetic magnetic resonance tomography (MRI) in comparison with extensive cross sections and histopathologic findings].

PURPOSE: To compare staging of advanced primary cervical carcinoma (pT2b-pT4a) by conventional and pharmacokinetic magnetic resonance imaging (MRI) with the giant cross section specimen and histopathological findings. MATERIALS AND METHODS: Seventeen patients with biopsy-proven cancer of the cervix and clinically suspected invasive cancer (FIGO IIB-IVA) were prospectively examined by conventional (T2 and contrast-enhanced T1-weighted spin echo images) and pharmacokinetic MRI. All MRI findings were compared with the giant cross section specimen and histopathology as the standard of reference. For pharmacokinetic MRI, a saturation recovery TurboFLASH sequence was used with a high temporal resolution of 13 s per ten sections. Signal time changes were analyzed using a pharmacokinetic model and the computed parameter values were visualized by color-coded overlay. RESULTS: Analysis of parametrial invasion on T2-weighted images resulted in an accuracy of 85% and 73% on contrast-enhanced T1-weighted images and on pharmacokinetic MR images respectively. Accuracy of analysis of bladder and/or rectal wall invasion was significantly (P < 0.05) higher on pharmacokinetic MR images (88%) than on T2-weighted images (67%). Contrast-enhanced T1-weighted spin-echo images improved staging accuracy compared with T2-weighted images (76% vs 67%). CONCLUSION: At present, conventional T2-weighted SE images are superior to contrast-enhanced T1-weighted SE and pharmacokinetic MR images in depicting infiltration of the parametrium. However, suspected infiltration of the bladder and/or rectum (pT4a) is diagnosed more accurately on pharmacokinetic images than on conventional MR images.

Adolescent↗

[Morphologic MR imaging with T1-weighted sequences for radiotherapy goal volume definition of intracranial tumors. Comparison with FLASH-Turbo-FLASH and SE sequences].

INTRODUCTION: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. METHODS: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the spinal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. RESULTS: The signal- and contrast-to-noise ratios were significantly (P < 0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions on Flash and Turbo-Flash images, respectively, good or very good tumor visibility when compared with conventional spin-echo images with a reduction of imaging time by a factor of 7-8. Flash and Turbo-Flash sequences were more prone to susceptibility artifacts, conventional spin-echo sequences more to pulsation artifacts in the posterior fossa. Tumor sizes were comparable in all three techniques. CONCLUSION: At present, conventional spin-echo images are superior to fast Flash and ultrafast Turbo-Flash sequences as a basis for accurate target volume definition in high-precision radiotherapy. However, fast Flash and Turbo-Flash images may be a practicable alternative to conventional spin-echo images for tumors in the posterior fossa or in patients unable to tolerate a stereotactic fixation device. Despite some limitations, Turbo-Flash sequences enable fast dynamic MR imaging combined with an acceptable morphology, which may be sufficient to target volume planning in high-precision radiotherapy.

Adult↗

[Classification of hemodynamic changes in renal artery stenosis using cine magnetic resonance phase contrast flow measurements].

PURPOSE: To evaluate the use of high-temporal resolution cine MR phase-contrast flow measurements for assessment of flow dynamics in renal artery stenosis (RAS). MATERIAL AND METHODS: In a dog model, cine MR flow measurements were validated by comparing the MR flow data to an invasive transit-time ultrasound reference technique for different degrees of RAS. Cardiac-gated MR flow curves were recorded in 56 renal arteries of 28 patients with a temporal resolution of at least 32 ms. In all cases RAS was confirmed by digital subtraction angiography (DSA). Abnormalities of flow dynamics were assessed in the calculated flow curves using the MR parameters mean flow, maximum velocity, and time to systolic maximum. RESULTS: By means of the MR blood flow parameters high-grade stenoses (> 50%, n = 23) were detected with sensitivity of 100% and specificity of 94% with reference to DSA. The overall differentiation between stenoses (n = 37) and non-stenosed vessels (n = 19) revealed a sensitivity of 87% and a specificity of 100%. CONCLUSION: Analysis of cardiac-gated MR flow curves provides a non-invasive method to assess the hemodynamic significance of RAS and thus allows a functional evaluation in relation to the morphologic characteristics of the stenosis.

Adolescent↗

Quantitative magnetic resonance imaging in geriatric depression and primary degenerative dementia.

Quantitative magnetic resonance imaging (MRI) was used to investigate volumes of different brain structures in 19 patients with late-onset major depression (DSM-III-R), 27 patients with Alzheimer's disease (NINCDS-ADRDA criteria) and 13 age matched controls. 3-D MRI sequences were acquired using a Siemens 1.5 T scanner. Whole brain volume, CSF volume, volume of the frontal and temporal lobes and the volume of the amygdala-hippocampus complex were assessed using the software NMR Win. Compared to the controls, depressed patients showed a significantly lower whole brain volume and a significantly higher CSF volume, whereas volumes of the frontal and temporal lobes as well as the amygdala-hippocampus complex volumes were not significantly decreased. In addition, depressed patients exhibited a higher ventricle-brain ratio suggesting a higher degree of central atrophy compared to healthy individuals. In contrast, Alzheimer patients showed significantly lower volumes than depressed patients and controls with respect to all volumetric parameters. Although the findings indicate the presence of brain atrophy in patients with late-onset depression, the pattern of volumetric changes in these patients differs markedly from that observed in patients with primary degenerative dementia.

Aged↗

Contrast-enhanced magnetization transfer imaging: improvement of brain tumor conspicuity and delineation for radiosurgical target volume definition.

PURPOSE: To assess the contrast-noise-ratio (CNR), and thus tumor conspicuity and delineation, on contrast-enhanced T1-weighted magnetization transfer (MT) images compared to conventional T1-weighted spin echo (SE) images as a strategy to improve definition of the macroscopic boost volume in radiosurgery treatment planning in patients with high grade gliomas or metastatic brain lesions. MATERIALS AND METHODS: Fifty patients (mean age, 51 years) with histologically proven or suspected high grade glioma or cerebral metastases were prospectively examined by MR imaging. Following gadolinium dimeglumine administration (0.1 mmol/kg body weight) the brain was imaged with both a T1-weighted MT-fast low angle shot (FLASH) pulse sequence and with a conventional T1-weighted SE sequence without MT saturation. Lesion conspicuity, size and CNR were compared for both techniques. RESULTS: The mean tumor diameter of malignant gliomas was significantly (P < 0.01) larger when measured on T1-weighted MT-FLASH images compared to T1-weighted SE images and was comparable for metastatic lesions. The mean CNR of enhancing lesions on T1-weighted MT-FLASH was 14 +/- 5 compared to 10 +/- 4 on SE images, representing a significant (P < 0.05) improvement. Lesion conspicuity and delineation was improved in 10 of 20 patients (50%) with high grade gliomas and in 15 of 30 patients (50%) with metastases. Additional contrast enhancing lesions were detected in 8 of 30 patients (27%) with metastases on MT-FLASH images. Lesion conspicuity was markedly improved in the posterior fossa. DISCUSSION: Contrast-enhanced T1-weighted MT-FLASH images improve lesion detection and delineation in the planning process of radiosurgery in patients with intracranial high grade gliomas or metastases and may even alter the treatment approach.

Adult↗

Intracranial meningeomas: time- and dose-dependent effects of irradiation on tumor microcirculation monitored by dynamic MR imaging.

The purpose of this study was the characterization of the time- and dose-dependent effects of irradiation on tumor microcirculation by means of dynamic MR imaging and correlation of the estimated data with tumor response in patients with meningeomas. Dynamic MR imaging studies were performed in 20 patients with intracranial meningeomas prior to (n = 20) and at 6 (n = 17), 18 (n = 17), and 50 wk (n = 14) after the end of radiotherapy. In seven of these patients, dynamic measurements were also performed during fractionated radiotherapy after approximate 20 Gy and 54 Gy. During and after short-time infusion of gadopentetate dimeglumine, the kinetics of lesion response was resolved using a strongly T1-weighted saturation recovery TurboFLASH (SRTF) sequence. The signal-time courses of the suspected lesions were analyzed using a pharmacokinetic two-compartment model. The calculated parameters amplitude A (reflecting gadopentetate dimeglumine accumulation in the extracellular space) and exchange rate constant k21 (depending on vascular permeability and blood flow) were displayed as color-coded images and analyzed as a function of time of therapy and radiation dose. All meningeomas showed a high exchange rate constant k21 (median, 5.7 min-1; range, 1.9-23.0 min-1) and a high amplitude A (median, 1.5 arbitrary units; range, 1.1-2.7) prior to X-ray treatment. During radiotherapy we found a dose related significant (p < .01) increase of k21 accompanied by an increase of the amplitude A as compared to the pretreatment values. Analysis of tumor volume 6, 18, and 50 wk after X-ray treatment revealed two different groups. In the responder group (n = 13) the median of the tumor volume decreased from 10.0 to 7.5 cm3. For this group, we found a significant drop (p < .01) of the median of the amplitude A and a decrease of the exchange rate constant k21. In the nonresponder group (n = 4) the median of the tumor volume increased after radiation from 3.5 to 4.5 cm3. The pharmacokinetic analysis revealed a decrease of the amplitude A-and an increase of the exchange rate constant k21. The response of meningeomas to radiotherapy is influenced by the effect of X-rays on tumor microcirculation. This effect on tumor microcirculation can be derived by analysis of pharmacokinetic maps obtained from dynamic MR images. Furthermore, these pharmacokinetic maps can possibly be used to differentiate groups of patients who respond or do not respond to radiotherapy and, thus, could benefit from another treatment modality.

Contrast Media↗

Serial MR imaging of intracranial metastases after radiosurgery.

PURPOSE: To evaluate the spatiotemporal evolution of radiosurgical induced changes both in metastases and in normal brain tissue adjacent to the lesions by serial magnetic resonance (MR) imaging. METHODS AND MATERIALS: Thirty-five intracranial metastases of different primaries were treated in 25 patients by single high-dose radiosurgery. MR images acquired before radiosurgery were available in all patients. Sixty-three follow-up MR studies were performed in these patients including T2- and contrast-enhanced T1-weighted MR images. The average follow-up time was 9 +/- 5 months (mean +/- standard deviation [SD]). Based on contrast-enhanced T1-weighted MR images, tumor response was radiologically classified in the following four groups: stable disease was assumed if the average tumor diameter after treatment did not show a tumor shrinkage of more than 50% and an increase of more than 25%, partial remission as a shrinkage of tumor size of more than 50%, a disappearance of contrast-enhancing tumor as a complete remission, and an increase of tumor diameter of more than 25% as tumor progress. Moreover, we analysed signal changes on T2-weighted images in brain parenchyma adjacent to the enhancing metastases. RESULTS: The overall mean survival time was 10.5 +/- 7 months, with a 1-year actuarial survival rate of 40%. Stable disease, partial or complete remission of the metastatic tumor was observed in 22 patients (88%). Central or homogeneous loss of contrast enhancement appeared to be a good prognostic sign for stable disease or partial remission. This association was statistically significant (p < 0.05). Three patients (12%) suffered from tumor progression. In eight patients (32%) with stable disease or partial remission, signal changes on T2-weighted images were observed in tissue adjacent to the contrast enhancing lesions. A progression of the high signal on T2-weighted images was seen in seven of the eight patients between 3 and 6 months after therapy, followed by a signal regression 6-18 months after irradiation. CONCLUSION: MR imaging is a sensitive imaging tool to evaluate tumor response as well as the presence or absence of adjacent parenchymal changes following radiosurgery. Loss of homogeneous or central contrast enhancement on Gd-enhanced MR images appeared to be a good prognostic sign for tumor response. Tumor shrinkage seems not to be dependent on time. In addition, most cases of radiation induced changes in normal brain parenchyma observed on T2-weighted images seem to be self limited.

Brain↗

Quantitative magnetic resonance imaging and neuropsychological functions in dementia of the Alzheimer type.

BACKGROUND: The aim of the present study was to investigate neuropsychological functions in dementia of the Alzheimer type (DAT) with respect to morphological changes that were revealed by quantitative magnetic resonance imaging (MRI). METHODS: Twenty patients with DAT (NINCDS-ADRDA criteria) and 10 healthy age and sex matched controls were included. The neuropsychological function was evaluated on a test battery covering the severity of dementia, verbal and visual memory, concentration and attention, language skills and general intelligence as well as activities of daily living. 3D MRI sequences were acquired using a 1.5 T Siemens MAGNETOM. Whole brain volume, total intracranial volume (TIV), volume of the frontal and temporal lobes and volumes of the amygdalahippocampus complex (AHC) were assessed using the newly developed software NMR Win. RESULTS: Apart from TIV all morphometric parameters differed significantly between the diagnostic groups. AHC volumes discriminated best between the groups, with only a small overlap. AHC atrophy exceeded generalized atrophy. These findings were confirmed when the data were reanalysed after dividing the DAT patients into a mildly and moderately affected group. The severity of dementia was significantly correlated with the volumes of the AHC and the volumes of the temporal lobes bilaterally, but not with the whole brain volume and the volumes of the frontal lobes. CONCLUSIONS: These results underline the important role of the temporal substructures for aetiology and progression of DAT. They indicate that the volume of the AHC can be monitored by MRI and may be used to follow up the disease process.

Aged↗

Renal artery stenosis: grading of hemodynamic changes with cine phase-contrast MR blood flow measurements.

PURPOSE: To analyze the blood flow dynamics in renal artery stenosis with high-temporal-resolution cine phase-contrast magnetic resonance (MR) flow measurements. MATERIALS AND METHODS: Cine phase-contrast MR flow measurements were invasively validated with real-time intraoperative transit-time ultrasound (US). In 23 patients, 48 renal artery stenoses were confirmed at digital subtraction angiography. Cardiac-gated cine phase-contrast MR flow measurements were obtained in 32-msec intervals, and flow curves were calculated for the whole cardiac cycle. Hemodynamic parameters evaluated included the decrease in mean flow and the delay and reduction in the systolic velocity maximum due to decrease in or absence of the early systolic peak. RESULTS: Overall differentiation between renal artery stenosis (n = 31) and nonstenosed vessels (n = 17) with cine phase-contrast MR revealed a sensitivity of 90% and specificity of 94% compared with findings at digital subtraction angiography. High-grade stenoses (>50%, n = 19) were detected with cine phase-contrast MR with sensitivity of 100% and specificity of 93%. CONCLUSION: Quantitative and qualitative analysis of cardiac-gated cine phase-contrast MR flow velocity curves provided a highly accurate method to detect hemodynamic abnormalities in patients with suspected renal artery stenosis.

Adolescent↗

Modulation by angiotensin II of endothelial cell control of DNA synthesis in human mesangial cells.

To determine whether angiotensin II (Ang II) may modulate the control by endothelial cells of DNA synthesis in mesangial cells, we cocultured human umbilical vein endothelial cells (HUVEC) and human mesangial cells. HUVEC released endothelin-1 (ET-1), and prostaglandin I(2) (PGI(2)). Ang II stimulated the production of PGI(2), but did not modify that of ET-1. DNA synthesis in mesangial cells estimated by [3H]-thymidine incorporation was increased when mesangial cells and endothelial cells were cocultured. The mitogenic effect of endothelial cells in coculture resulted from ET-1 production since it was suppressed by bosentan, a mixed specific ET-1 receptor antagonist. The effects of Ang II on mesangial cell proliferation varied according to the protocol. Under control conditions, Ang II was inactive. In the presence of HUVEC-conditioned medium, Ang II exerted a mitogenic effect. By contrast, Ang II inhibited DNA synthesis by mesangial cells in the experiments of coculture. The latter effect could be attributed to HUVEC-released PGI(2) via the increase of cyclic AMP in mesangial cells since it was abolished by indomethacin, a cyclooxygenase inhibitor. In conclusion, endothelial cells may stimulate DNA synthesis in mesangial cells via ET-1 production and Ang II inhibits this effect by stimulating PGI(2) production in endothelial cells. In contrast, Ang II reinforces the mitogenic effect of the endothelial cell-conditioned medium when it acts directly on mesangial cells.

6-Ketoprostaglandin F1 alpha↗

Hyperpolarized gases--a new type of MR contrast agents?

The nuclear spin polarization of noble gases can be strongly enhanced by laser optical pumping followed by electron-nuclear polarization transfer. Direct optical pumping of metastable 3He atoms has been shown to produce enormous polarization in the order of 0.4-0.6. This is about 10(5) times greater than the polarization of water protons at thermal equilibrium used at conventional MR imaging. We demonstrate that hyperpolarized 3He gas can be applied to nuclear MR imaging of human organs with air-filled spaces. In vivo 3He MR experiments were performed in a whole-body MR scanner with a superconducting magnet ramped down to 0.8 T and at 1.5 T using a double resonant Helmholtz coil operating at 63.6 and 48.6 MHz for 1H and 3He, respectively. Anatomical details of the lungs of a volunteer were visualized with the FLASH technique demonstrating the potential of the method for fast imaging of airways in the human body and for pulmonary ventilation studies.

Contrast Media↗

Interest and limits of in vitro studies in renal vascular endocrinology.

Various in vitro preparations have been utilized to study the cellular activity of vasoactive agents on renal cortical microvessels and on mesangial cells. The receptors and the transduction pathways of bradykinin and atrial natriuretic factor were characterized on cultured cortical vascular smooth muscle cells from the rabbit kidney. A preparation of afferent arterioles that had been freshly isolated from the rat kidney was used to study the NO-dependent regulation of renin release. The influence of endothelin and angiotensin II on mesangial cell proliferation was evaluated, using cocultures of human endothelial and mesangial cells. These appropriate in vitro preparations have provided new insights on renal vascular endocrinology. However, extrapolation of in vitro data to in vivo physiology must be cautious because the phenotype of vascular cells often changes in culture conditions.

Animals↗

Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI.

In this methodological paper the authors report the stereotactic correlation of different magnetic resonance imaging (MRI) techniques [MR angiography (MRA), MRI, blood bolus tagging (STAR), and functional MRI] in 10 patients with cerebral arteriovenous malformations (AVM) and its application in precision radiotherapy planning. The patient's head was fixed in a stereotactic localization system that is usable at the MR and the linear accelerator installations. By phantom measurements different materials (steel, aluminium, titanium, plastic, wood, ceramics) used for the stereotactic system were tested for mechanical stability and geometrical MR image distortion. All metallic stereotactic rings (closed rings made of massive metal) led to a more or less dramatic geometrical distortion and signal cancellation in the MR images. The best properties-nearly no distortion and high mechanical stability-are provided by a ceramic ring. If necessary, the remaining geometrical MR image distortion can be "corrected" (reducing displacements to the size of a pixel) by calculations based on modeling the distortion as a fourth-order two-dimensional polynomial. Using this method multimodality matching can be performed automatically as long as all images are acquired in the same examination and the patient is sufficiently immobilized. Precise definition of the target volume could be performed by the radiotherapist either directly in MR images or in calculated projection MR angiograms obtained by a maximum-intensity projection algorithm. As a result, information about the hemodynamics of the AVM was provided by a three-dimensional (3D) phase-contrast flow measurement and a dynamic MRA with the STAR technique leading to an improved definition of the size of the nidus, the origin of the feeding arteries, and the pattern of the venous drainage. In addition, functional MRI was performed in patients with lesions close to the primary motor cortex area leading to an improved definition of structures at risk for high-dose application in radiosurgery. The different imaging techniques of MR provide a sensitive, noninvasive, 3D method for defining target volume, critical structures, and for calculating dose distributions for radiosurgery of cerebral arteriovenous malformations, because dose calculation of radiosurgery at sufficient accuracy can be based on 3D MR data of the geometrical conformation of the patient's head.

Algorithms↗

Monitoring of task performance during functional magnetic resonance imaging of sensorimotor cortex at 1.5 T.

Functional magnetic resonance imaging (fMRI) has found widespread clinical interest. Difficulties in clinical use of the fMRI technique arise, considering the lack of knowledge about activation task performance. This accounts especially for sensorimotor activation studies, in which performance of the sensorimotor activation task is-if at all-usually rated visually by subjective or semiquantitative methods (i.e., defining categories of performance such as neurological soft signs scales). Recently, instrumental methods for the measurement and analysis of motor performance have been developed. Pronation/supination (hand rotation) movement was shown to be an easily measurable and promising motor task. We have adapted a mechanic device (pronation/supination device, PSD) to monitor motor performance during the fMRI experiment. In a feasibility study, an investigation of fMRI activation strength dependence of sensorimotor cortices and supplementary motor area upon task frequency (25, 50, and 75 cycles/min) was carried out on 10 right-handed healthy volunteers. Furthermore, the authors report the observation of stimulus-induced activation changes in the cerebellum during pronation/supination movement.

Hand↗

Cerebral arteriovenous malformations: improved nidus demarcation by means of dynamic tagging MR-angiography.

Our purpose was to further improve the target volume definition for radiosurgical treatment of cerebral arteriovenous malformations (AVMs) by means of dynamic MRA (dMRA) using a blood bolus tagging sequence. We therefore compare this technique with 3D-TOF-MRA and transfemoral high resolution angiography in plain film technique. Twenty patients with angiographically proven cerebral AVMs were investigated by dMRA, TOF-MRA, and conventional angiography during the MR-assisted radiosurgical planning protocol. The patient's head was fixed in an MR-compatible stereotactic device. The different angiography techniques were evaluated by consensus of two radiologists. AVMs were characterized by the number and origin of feeding arteries, the maximum diameter of the AVM nidus, and the venous drainage pattern. Dynamic MRA was able to demonstrate the complete AVM characteristics and hemodynamics in 12 out of 20 patients. In three patients with an AVM nidus smaller than 1 cm in diameter the technique could not reliably depict the malformation. Technical problems due to steel screws and pins in the initially used stereotactic frame occurred in five patients. Due to reduced vessel overlap and the lack of disturbances caused by formations with short T1 time, dMRA was superior to TOF-MRA in the detection and the exact localization of the AVM nidus in four patients. We conclude that dMRA is able to demonstrate reliably AVM characteristics and hemodynamics in AVMs with a nidus larger than 1 cm in diameter. Because of the improved demarcation of the AVM nidus, this technique may be a valuable adjunct to radiosurgery planning of cerebral AVMs.

Adult↗

Functional MR imaging of visual and motor cortex stimulation at high temporal resolution using a FLASH technique on a standard 1.5 Tesla scanner.

Functional magnetic resonance imaging (fMRI) was performed on a conventional 1.5 T scanner by means of a modified FLASH-technique at temporal resolutions of 80 and 320 ms. The method's stability was assessed by phantom measurements and by investigation of three volunteers resulting in a low amplitude (3%) periodic (4 s) signal modulation for the in vivo measurements, which was not observable in the phantom experiments. fMRI activation studies of motor and visual cortices of four adjacent slices were carried out on 12 healthy right-handed volunteers. Stimulation was performed by a triggered single white light flash or single finger-to-thumb opposition movement, respectively. Event-related response of visual and motor activation was traced over 10.24 s with a temporal resolution of 320 ms for the four slice measurements. Brain activation maps were calculated by correlation of measured signal time course with a time-shifted boxcar function. Activation was quantified by calculation of percentual signal change in relation to the baseline. Observed signal magnitudes were about 5-7% in visual and about 8-12% in primary motor cortex. While photic response was delayed by about 2 s, motor stimulation showed an instantaneous increase of the MR signal. MR signal responses for both stimuli had decayed completely after about 5 s. Our results show that event-related fMRI enables mapping of brain function at sufficient spatial resolution with a temporal resolution of up to 80 ms on a conventional scanner.

Adult↗

Macroscopic tumor volume of malignant glioma determined by contrast-enhanced magnetic resonance imaging with and without magnetization transfer contrast.

The purposes of this study were to compare the conspicuity and lesion volume of contrast-enhancing macroscopic malignant glioma determined by postcontrast magnetic resonance (MR) imaging with and without magnetization transfer (MT) saturation, and to discuss possible implications for radiotherapy planning. Nineteen patients (age 24-60 years) with histologically proven malignant glioma were prospectively examined by MR imaging. After the administration of gadolinium dimeglumine (0.1 mmol/kg body weight), the lesions were imaged with an MT-weighted FLASH (fast, low-angle shot) pulse sequence and with a conventional T1-weighted spin-echo (SE) sequence without MT saturation. The mean tumor volumes of gliomas measured on MT-weighted FLASH images were significantly (p < .01) larger than those obtained from T1-weighted SE images (45 +/- 15 cm3 vs. 33 +/- 10 cm3). The mean contrast-to-noise ratio of enhancing lesions on MT-weighted FLASH was 48 +/- 14 compared with 30 +/- 14 on SE images, representing a significant (p < .01) improvement. We conclude that the volume of contrast enhancement of malignant glioma identified on MT-weighted FLASH images represents the area of disrupted blood-brain barrier. If this volume of subtle contrast enhancement is caused by tumor infiltration and represents the boost target volume for stereotactic radiosurgery or brachytherapy, MT-weighted FLASH images would be better than T1-weighted SE images to define these volumes. These improved delineation of areas at highest risk for recurrence following radiation therapy should enhance the efficacy of treatment planning for high-boost therapy.

Adult↗

Functional magnetic resonance imaging in a stereotactic setup.

The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the patients has been immobilized for stereotactic treatment planning either with a self developed stereotactic ceramic frame and bony fixation or with an individual precision mask system made of light cast. It has been shown that this frame does not produce any image distortion. fMRI was performed using a modified FLASH sequence on a conventional 1.5 T MRI scanner with a specially developed linear polarized head coil. The imaging technique used was an optimized conventional 2D and 3D, first order flow rephased, gradient echo sequence (FLASH) with fat-suppression and reduce bandwidth (16-28 Hz/pixel) and TR = 80-120 ms, TE = 60 ms, flip angle = 40 degrees, matrix = 128 x 128, FOV = 150-250 mm, slice-thickness = 2-5 mm, NEX = 1, and a total single scan time for one image of about 7 sec. The motor cortex stimulation was achieved by touching each finger to thumb in a sequential, self-paced, and repetitive manner. Statistical parametric maps based on student's test were calculated. Pixels with a highly significant signal increase (p < 0.001) are overlaid on T1w SE images. The primary motor and sensory cortex could be visualized with this method in all 10 patients that were imaged in this study. Due to tight fixation of the patient's skull there have been no motion artifacts. These results show that functional MRI is feasible in an stereotactic set-up with an standard 1.5 T scanner. This is a prerequisite for the exact pre therapeutic assessment of the function of cortical centers.

Brain↗