PubMed Health⌕ Search

Biomedical subjects

M F Aillaud

Publications and source records attributed to M F Aillaud.

At least 19 recordsLinked to original sources

Effect of Interleukin-6 promoter polymorphisms in survivors of myocardial infarction and matched controls in the North and South of Europe. The HIFMECH Study.

Elevated plasma IL-6 levels have been implicated in the pathogenesis of coronary heart disease. We have investigated the association of two polymorphisms in the promoter of IL-6 (-572G>C and -174G>C) with levels of inflammatory markers and risk of myocardial infarction (MI) in a European study of MI survivors and age-matched controls from two high-risk centres in the North of Europe, and two low risk centres in the South. IL-6 and CRP levels were similar in controls in both regions, but were higher in cases. For the -174G>C polymorphism the rare -174C allele showed a regional difference in allele frequency, being more common in the North European group (0.43 vs 0.28; p < 0.0005), where -174C allele carriers showed an apparent reduced risk of MI compared to -174GG homozygotes (OR 0.53, 95%CI 0.32, 0.86). No such effect was observed in the South or with the -572G>C in either group. Neither genotype was associated with a significant effect on plasma IL-6 levels in either cases or controls. Furthermore, no regional difference was observed in the frequency of the -572G>C SNP, suggesting that these polymorphisms are unlikely to be contributing to the observed increased risk of cardiovascular disease in Northern Europe.

Adult↗

Weak and non-independent association between plasma TAFI antigen levels and the insulin resistance syndrome.

Increased plasma thrombin-activatable fibrinolysis inhibitor (TAFI) levels were recently shown to be a part of the insulin resistance syndrome. We investigated the relationship between plasma TAFI antigen levels and insulin resistance markers and compared these results with those obtained for PAI-1 and fibrinogen which are known to be closely related to insulin resistance syndrome and fat mass, respectively. Eighty-nine obese females had 1.3-, 1.2-, and 3-fold higher circulating TAFI, fibrinogen and PAI-1, respectively, compared with 64 lean females. Univariate analysis showed that the significance level for association between TAFI or fibrinogen concentrations and insulin resistance markers was lower than the significance level for association between PAI-1 and insulin resistance markers. Nevertheless, TAFI, fibrinogen, and PAI-1 plasma levels were significantly associated to each other. In linear stepwise ascendant analysis, insulin resistance markers accounted for 50% of the interindividual variability of plasma PAI-1 and only for 10% of plasma TAFI and 13% of fibrinogen variability. The contribution of insulin resistance markers to plasma TAFI antigen levels variability disappeared when PAI-1 or fibrinogen was entered in the statistical model. TAFI mRNA was detected in the liver but not in adipose tissue and endothelial cells. No TAFI mRNA was detected in normal or atherosclerotic vessels either. These results suggest that elevated TAFI antigen levels found in obese subjects are not independently associated with the metabolic markers of the insulin resistance syndrome. Increased plasma TAFI antigen levels in obesity might reflect a specific pathway of regulation at the liver level.

Adipose Tissue↗

The plasminogen activator inhibitor-1 -675 4G/5G genotype influences the risk of myocardial infarction associated with elevated plasma proinsulin and insulin concentrations in men from Europe: the HIFMECH study.

UNLABELLED: Although the potential role of plasminogen activator inhibitor-1 (PAI-1) in the development of coronary artery disease is strongly supported by its biological characteristics, results of clinical studies remain controversial. OBJECTIVES: To investigate whether plasma PAI-1 concentrations and the -675 4G/5G polymorphism located in the PAI-1 gene could constitute risk markers for myocardial infarction (MI). PATIENTS AND METHODS: We used a European case-control study, the HIFMECH study, comparing 598 men with MI and 653 age-matched controls. RESULTS: Insulin resistance explained a major part of the variation in PAI-1 (24%) whereas inflammation had only a minor contribution (0.01%). For both cases and controls plasma PAI-1 concentrations were significantly higher in the North than the South, and in both regions were higher in individuals with MI compared with control subjects [overall odds ratio (OR) for a 1 SD increase=1.54, 95% confidence interval (CI) 1.34, 1.77]. This difference was observed in all the centers studied. Overall, the difference between cases and control subjects remained significant after controlling for inflammation variables (OR=1.30, 95% CI 1.08, 1.57), but lost significance after controlling for insulin resistance variables (OR=1.17, 95% CI 0.98, 1.40). The 4G allele was associated with significantly higher PAI-1 levels in cases but not controls and, taken independently, did not modify the risk of MI (P=0.9). However, a significant interaction was observed with both insulin or proinsulin and the risk of MI (P=0.05 and 0.02, respectively), but not with triglycerides or body mass index (BMI). The insulin or proinsulin effect on risk was observed only in the carriers of the 4G/4G genotype. This interaction appeared not to be mediated by plasma PAI-1 antigen concentrations (P=0.01 and 0.02 after adjustment for PAI-1 plasma levels). The interaction with proinsulin but not insulin remained statistically significant after further adjustment for other factors associated with insulin resistance (triglycerides and BMI) and C-reactive protein (P=0.01). CONCLUSION: This study suggests that PAI-1 has a role in risk of MI in the presence of underlying insulin resistance. A significant interaction between insulin or proinsulin and the -675 4G/5G polymorphism was observed in risk for MI. The mechanisms for these interactions remain to be determined.

Case-Control Studies↗

Plasma thrombin-activatable fibrinolysis inhibitor antigen concentration and genotype in relation to myocardial infarction in the north and south of Europe.

The thrombin-activatable fibrinolysis inhibitor (TAFI) is a recently described inhibitor of fibrinolysis that decreases plasminogen binding to the fibrin surface. The plasma TAFI concentration is almost entirely genetically determined. We investigated whether plasma TAFI levels and polymorphisms located in the TAFI gene could constitute risk markers of myocardial infarction (MI). Plasma TAFI antigen (Ag) levels were assayed by ELISA and 2 TAFI gene polymorphisms (Ala147Thr and C+1542G in the 3' untranslated region) were determined in a large European case-control study. This study compared 598 men recruited 3 to 6 months after MI with 653 age-matched controls from North Europe (Stockholm, Sweden, and London, England) and South Europe (Marseilles, France, and San Giovanni Rotondo, Italy). A TAFI Ag value above the 90th percentile was associated with a significantly lower risk of MI (odds ratio 0.55, P<0.02), indicating that elevated TAFI may be protective against MI. As previously shown, the 2 TAFI gene polymorphisms were in strong linkage disequilibrium and were associated with the TAFI Ag concentration, with carriers of the Thr147 and 1542C alleles having higher levels (P<0.0005). These effects were similar in controls and cases and in each center. There was a difference in allele frequency between cases and controls for the Ala147Thr polymorphism, with Thr147 allele carriers being more frequent in controls than in cases in 2 centers, Stockholm (P=0.03) and San Giovanni Rotondo (P=0.03); the odds ratio for the entire cohort was 0.78 (P<0.05). In conclusion, patients with a recent MI presented lower values of TAFI Ag and higher frequencies of the "TAFI-decreasing" alleles. The geographical differences observed do not contribute to explaining the North-South gradient in MI risk in Europe.

Alleles↗

Haemostasis in relation to dietary fat as estimated by erythrocyte fatty acid composition: the prime study.

We investigated whether haemostatic variables were related with dietary fatty acid composition as estimated by the fatty acid content of erythrocytes. Subjects were a subsample (n=283) of the participants in the Prospective Epidemiological Study of Myocardial Infarction (PRIME) Study. Factor VII, fibrinogen, tissue-type plasminogen activator antigen (tPA-ag), plasminogen activator inhibitor type 1 (PAI-1), D-dimer and von Willebrand factor (vWf) were measured and the fatty acid composition was determined in the phospholipids of total erythrocytes by gas chromatography. Statistical analyses were performed using multiple linear regression analyses with adjustment for age, center and body mass index. tPA-ag was significantly related to the n-3 fatty acids derived from fish. This was reflected in an inverse association of all n-3 fatty acids combined with tPA-ag (beta=-0.37 ng/ml/%, 95% confidence intervals: -0.45, -0.29, P<.01). Positive and significant associations of D-dimer with arachidic and eicosamonoenoic acid were observed (P<.01). No relationships were found between fatty acids and fibrinogen, vWf, PAI-1 or factor VII. The results of this study suggest that consumption of n-3 fatty acids derived from fish may favourably influence tPA-ag.

Body Mass Index↗

The clinical relevance of the citrate effect on International Normalized Ratio determinations depends on the reagent and instrument combination used.

Multiple studies have shown that the two different citrate concentrations in common use as the anticoagulant in blood collection for haemostasis assays can affect the results obtained with the prothrombin time assay. It is clear from the literature that there is considerable variability in the results obtained using different instrument-reagents combinations, but the clinical relevance of these differences is unclear. Most of the studies have used an optical system for end-point detection. This study reports on the citrate sensitivity using mechanical end-point detection. Using two different reagents, one previously shown to be citrate sensitive on optical systems (Neoplastin CI plus) and a citrate-insensitive reagent (Neoplastin CI), we demonstrate that the effect of using different citrate concentrations (0.105 or 0.129 mol/l) has statistically significant but clinically irrelevant effects on the International Normalized Ratio using a mechanical instrument (STA)-reagent combination (mean percentage difference in results, 1.9 and 3.8% respectively). This demonstrates that the citrate effect is both instrument type and reagent dependent. Every reagent and instrument combination needs to be tested to see whether any citrate effect exists. In a secondary study, it was shown that the international reference rabbit thromboplastin (CRM 149(s)) was not citrate-concentration sensitive.

Animals↗

Antibodies to phosphatidylethanolamine as the only antiphospholipid antibodies found in patients with unexplained thromboses.

The objective of this study was to assess the interest of antiphosphatidylethanolamine antibodies (aPE) in unexplained thrombosis (UT) defined as thrombotic episode without any of the main autoimmune and hereditary thrombophilic defects. Results from 98 UT were compared to those of (I) 142 patients with thrombophilia: 67 antiphospholipid syndrome (APS) and 75 hereditary hemostatic defects (HHD); (II) 110 patients without thrombosis: 60 with systemic lupus erythematosus (SLE) and 50 with infectious diseases (ID). As compared to controls (100 blood donors), aPE prevalence was significantly higher in both autoimmune contexts (APS: 43%; SLE: 40%, p<0.0001) and among non-autoimmune pathologies, only in UT (18%, p = 0.001) conversely to HHD (8%) or ID (10%). aPE prevalence in UT was not statistically different from that found in Primary APS (32%, p = 0.076) but lower than in Secondary APS (65%, p <0.005). In UT, aPE were mainly of IgM isotype like in Primary APS and they were found alone whereas in SLE they were always associated with classical antiphospholipid antibodies. No significant association was found between any isotype of aPE and a site of thrombosis in UT as well as in APS. In conclusion, this study demonstrates an increase of the prevalence of aPE in patients with unexplained thrombosis. Thus, aPE investigation appears to be of interest in UT and their persistent presence could define a biological variant of APS.

Adult↗

Plasma levels of free and total TFPI, relationship with cardiovascular risk factors and endothelial cell markers.

Free-TFPI (f-TFPI) presents high anticoagulant activity and its plasma level correlates with unfavorable outcomes in unstable angina. Total TFPI (t-TFPI) represents mainly the lipid-bound form which seems to have a poor anticoagulant activity. Until now, it is not known whether the variations of f-TFPI plasma levels are determined by environmental factors. The aim of our study was to evaluate the influence of cardiovascular risk factors on plasma levels of f-TFPI and relations with other endothelial derived molecules in a population of 626 patients (277 men and 349 women) attending a metabolic ward for primary prevention of coronary disease. Free and total TFPI plasma levels were poorly correlated. f-TFPI levels increased with age in both sexes, t-TFPI in women only. Age-adjusted correlations of TFPI levels with conventional cardiovascular risk factors and endothelial cell markers showed different patterns for f-TFPI and t-TFPI. f-TFPI correlated with parameters associated with insulin resistance, particularly in females. f-TFPI was also positively associated in both genders with fibrinogen and endothelial cell markers: t-PA, thrombomodulin (TM) and von Willebrand factor (vWF). t-TFPI correlated strongly with LDL-C in both sexes. It also correlated negatively with parameters of the insulin resistance syndrome. t-TFPI also correlated with TM but not with other endothelial cell markers. The results of the multivariate step by step analysis showed that cardiovascular risk factors poorly explained the f-TFPI variability (7% and 4% in men and women, respectively), whereas they explained 16 and 20% of t-TFPI variability in men and women respectively (mostly related to LDL-C). In conclusion, this study showed that free- and total-TFPI are regulated differently. f-TFPI strongly correlates with endothelial cell markers and t-TFPI is more related to conventional cardiovascular risk factors. The strong gender effect on f-TFPI levels remains to be explained.

Age Factors↗

The A -844G polymorphism in the PAI-1 gene is associated with a higher risk of venous thrombosis in factor V Leiden carriers.

Identification of combined genetic factors in factor V Leiden carriers is important for a more accurate risk assessment for venous thrombosis (VT). Among these individuals, we evaluated the role of polymorphisms of the plasminogen activator inhibitor-1 (PAI-1) gene in the thrombophilic phenotype. A total of 382 factor V Leiden carriers were included in the study. This population was divided into 3 groups. Group 1 (n=168) included individuals with a personal history of VT; group 2 (n=140) included individuals without personal VT but with a familial history of VT; and group 3 (n=74) included individuals without VT and with a fortuitous discovery of the factor V Leiden mutation. We compared the genotype distribution of 2 polymorphisms, A -844G and -675 4G/5G, located in the promoter region of the PAI-1 gene among these 3 groups of individuals. The A -844G allele frequency differed significantly among the 3 groups (P=0.048), the A allele being more frequent in patients who suffered from VT (61%) than in subjects without VT (52%, P=0.015), whereas no difference was observed between the 2 groups of asymptomatic individuals. The prevalence of genotype AA carriers was higher in patients with VT (38%) than in asymptomatic individuals (21%, P=0. 015), leading to an odds ratio of 1.74 (95% confidence interval, 1.3 to 3.8). Carrying the AA genotype conferred a risk of deep VT of 2. 08 (95% confidence interval, 1.28 to 3.40), whereas it did not seem to significantly influence the risk of pulmonary embolism. Concerning the -675 4G/5G polymorphism, no significant difference was observed among the 3 groups, the 4G allele frequency being 0.54 (in group 1), 0.49 (in group 2), and 0.45 (in group 3). These data suggest a role for the -A844G PAI-1 gene polymorphism in the thrombophilic phenotype of factor V Leiden carriers.

Adolescent↗

Fluvastatin decreases soluble thrombomodulin in cardiac transplant recipients.

We conducted a randomized, placebo controlled, double-blind, cross-over study, to assess the effects of a 4-week fluvastatin therapy on plasma markers of endothelial activation or injury in 20 transplanted heart recipients. The levels of thrombomodulin and von Willebrand factor antigen were higher at baseline in cardiac transplant recipients than in age and sex-matched healthy controls. Plasma total cholesterol showed a 21% reduction on fluvastatin therapy (p = 0.0001). Fluvastatin treatment had no significant effect on creatininemia, plasma cyclosporine, PAI-1 antigen, PAI-1 activity, tPA antigen, and Von Willebrand factor. However, fluvastatin produced a significant decrease of plasma thrombomodulin (66.7 ng/ml on placebo versus 58.8 ng/ml on fluvastatin, p <0.001), suggesting a rapid improvement of endothelial injury in these patients.

Aged↗

Screening for identified and unidentified protein C pathway defects by the Agkistrodon contortrix venom test in consecutive patients.

To determine the real performance of the Agkistrodon contortrix venom (ACV) screening test for protein C (PC) pathway defects, we studied 400 consecutive patients referred for the study of personal venous thrombosis or for family study. All 82 patients with factor V Arg 506 Gln (FV R506Q) (n = 82), 6 patients with activated PC resistance without FV R506Q, 17 patients with PC deficiencies, and 9 patients with combined defects were identified by an abnormal ACV result. Three of 6 protein S deficiencies overlapped the normal range. Among the 280 patients without a PC pathway defect, 63 of 193 with thrombosis and 18 of 87 asymptomatic subjects (relatives of patients with thrombosis) had an abnormal ACV result. A significant linear inverse relationship was observed between the ACV results and factor VIII. However, 31 of 63 patients (49%) with thrombosis and 15 of 18 (83%) asymptomatic subjects with an abnormal ACV had a normal factor VIII level. This test, with a 100% negative predictive value, is reliable for screening for PC deficiencies and for FV R506Q and can be used safely as an exclusion test. Moreover, the test may be useful to indicate, in the PC pathway, unidentified risk factors for venous thrombosis.

Adolescent↗

Multicenter evaluation of lyophilized and deep-frozen plasmas for assignment of the International Normalized Ratio.

The interlaboratory variation of the International Normalized Ratio (INR) in various external quality assessment schemes is still relatively high. This is partly caused by inaccuracy of manufacturers' stated International Sensitivity Index (ISI) and/or local instrumentation effects. The interlaboratory variation and accuracy of INR determinations may be improved by a local calibration procedure based on lyophilized plasmas with assigned INRs. The purpose of the present study was to determine INR values for different types of lyophilized plasmas to be used for local calibration. A total of 13 lyophilized plasmas (one normal, six from coumarin-treated patients, six artificially depleted) were analyzed by 10 laboratories, each using five calibrated prothrombin time (PT) systems. INRs were calculated for each plasma using each laboratory's specific ISI and mean normal prothrombin time values. In the same way, five deep-frozen pooled plasmas from coumarin-treated patients were analyzed. There were significant INR differences for the lyophilized plasmas between the prothrombin time systems. The differences were relatively small for the deep-frozen coumarin plasmas (CV 2.6-3.3%) and three lyophilized coumarin plasmas from one manufacturer (CV 3.7-4.8%). Important INR differences were observed for three lyophilized coumarin plasmas from another manufacturer (CV 9.5-14.1%) and several artificially depleted plasmas (CV 5.3-12.8%). The citrate concentrations in the artificially depleted plasmas were lower than those in the normal and coumarin plasmas. These differences should be considered in the selection and certification of plasmas as calibrants for local calibration of PT systems. The lyophilized plasmas' INR values obtained in the present study will be used for a field study of local PT calibration to assess their efficacy.

Animals↗

Influence of three types of automated coagulometers on the international sensitivity index (ISI) of rabbit, human, and recombinant human tissue factor preparations--a multicenter study.

Five tissue factor reagents and three types of automated instruments for prothrombin time (PT) determination were studied in an international multicenter collaborative exercise. The purpose of this work was to determine the international sensitivity index (ISI) for each combination of reagent and instrument against the international reference preparation RBT/90. Each type of instrument was used by 3 or 4 centers to assess the interlaboratory variation of the ISI. The interlaboratory variation of the ISI for each combination of reagent and instrument ranged between 0.4% and 7.8% coefficient of variation. For three reagents, the mean ISI values for ACL (nephelometric) and STA (mechanical) were practically identical, but the mean ISI values for MLA (photo-optical) were at least 10% higher. For two other reagents prepared from rabbit tissue, the mean ISI values increased in the order ACL, STA, MLA. The widest range of mean ISI values was noted with one rabbit tissue factor reagent: 1.68 for ACL and 2.00 for MLA. Exclusion of patient specimens with INR <1.5 and INR >4.5 determined by the international reference preparation resulted in a slight decrease of the mean ISI. The interlaboratory variation of the International Normalized Ratio (INR) was assessed from the results obtained with common lyophilized and deep-frozen plasmas. The use of instrument-specific ISI values resulted in reduced interlaboratory variation of the INR. It is recommended that thromboplastin manufacturers provide instrument-specific ISI values.

Animals↗