PubMed Health⌕ Search

Biomedical subjects

M F O'Brien

Publications and source records attributed to M F O'Brien.

93 records · Page 6Linked to original sources

The Cryolife-O'Brien stentless aortic porcine xenograft valve.

BACKGROUND: The advantageous design of the Cryolife-O'Brien stentless porcine aortic valve permits specific quick, easy, supravalvular implantation using single layer continuous 3-0 polypropylene suture. The advantages, contraindications, and implantation errors to avoid are detailed. The use of this valve for aortic valve replacement in the elderly population has been directed to proving its efficacy and establishing its grounds for durability while maintaining all of the advantages of a stentless tissue valve. METHODS: From December 1992 to September 1998, this valve was used in 240 patients (mean age 73 years: 15% > 80 years), 45% receiving associated coronary artery grafting (2.4 grafts per patient). Left ventricular (LV) myomectomy was necessary in 12% of patients. Detailed postoperative follow-up (100%) analysis included 650 serial echocardiographic studies. RESULTS: The 30-day mortality was low at 1.2% (3 deaths of 240 elderly patients). Ten patients had late mortality (1.5 months to 5 years), all nonvalve related. No structural failure and one only explant for endocarditis have occurred. Echocardiographic analyses have shown low mean transvalvular gradients in relationship to time (8.18 mmHg at 18 months) and to valve size (8.52 mmHg for a 23-mm host aortic annulus). Incompetence has been zero or a trace in 97% of the patients at 21/2 years. No patient over the 6 years shows valve deterioration. CONCLUSION: Six years of experience with this stentless valve in 240 elderly patients has revealed the many advantages of this safe, composite, and truly stentless device that is assembled without the need for Dacron support. Excellent sustained hemodynamics with low gradients, minimal regurgitation, and a good effective orifice have been coupled with low immediate mortality, no intrinsic valve failure, and one explant for endocarditis. Marked LV regression and minimal late valve-related complications confirm the safety and advantages of this stentless valve.

Aged↗

How to do safe sternal reentry and the risk factors of redo cardiac surgery: a 21-year review with zero major cardiac injury.

OBJECTIVES: Resternotomy is a common part of cardiac surgical practice. Associated with resternotomy are the risks of cardiac injury and catastrophic hemorrhage and the subsequent elevated morbidity and mortality in the operating room or during the postoperative period. The technique of direct vision resternotomy is safe and has fewer, if any, serious cardiac injuries. The technique, the reduced need for groin cannulation and the overall low operative mortality and morbidity are the focus of this restrospective analysis. METHODS: The records of 495 patients undergoing 546 resternotomies over a 21-year period to January 2000 were reviewed. All consecutive reoperations by the one surgeon comprised patients over the age of 20 at first resternotomy: M:F 343:203, mean age 57 years (range 20 to 85, median age 60). The mean NYHA grade was 2.3 [with 67 patients (I), 273 (II), 159 (III), 43 (IV), and 4 (V classification)] with elective reoperation in 94.6%. Cardiac injury was graded into five groups and the incidence and reasons for groin cannulation estimated. The morbidity and mortality as a result of the reoperation and resternotomy were assessed. RESULTS: The hospital/30 day mortality was 2.9% (95% CI: 1.6%-4.4%) (16 deaths) over the 21 years. First (481), second (53), and third (12) resternotomies produced 307 uncomplicated technical reopenings, 203 slower but uncomplicated procedures, 9 minor superficial cardiac lacerations, and no moderate or severe cardiac injuries. Direct vision resternotomy is crystalized into the principle that only adhesions that are visualized from below are divided and only sternal bone that is freed of adhesions is sewn. Groin exposure was never performed prophylactically for resternotomy. Fourteen patients (2.6%) had such cannulation for aortic dissection/aneurysm (9 patients), excessive sternal adherence of cardiac structures (3 patients), presurgery cardiac arrest (1 patient), and high aortic cannulation desired and not possible (1 patient). The average postop blood loss was 594 mL (95% CI:558-631) in the first 12 hours. The need to return to the operating room for control of excessive bleeding was 2% (11 patients). Blood transfusion was given in 65% of the resternotomy procedures over the 21 years (mean 854 mL: 95% CI 765-945 mL) and 41% over the last 5 years. CONCLUSIONS: The technique of direct vision resternotomy has been associated with zero moderate or major cardiac injury/catastrophic hemorrhage at reoperation. Few patients have required groin cannulation. In the postoperative period, there was acceptable blood loss, transfusion rates, reduced morbidity, and moderate low mortality for this potentially high risk group.

Adult↗

Experiences with redo aortic valve surgery.

OBJECTIVES AND METHODS: Reoperations are an integral part of a cardiac surgeon's practice. We share our experience of 546 reoperations over the last 21 years to January 2000, with the focus directed towards the timing of reoperation, reducing the mortality and morbidity of reoperation and rereplacement aortic valve surgery, and understanding the important risk factors. In addition, the precise technical steps that facilitate careful successful explantation of various devices (allograft, stented and stentless xenografts, and mechanical valves) are detailed. RESULTS: Optimal planned reoperation before deterioration to New York Heart Association Class III/IV levels and before unfavorable cardiac and comorbidity general system failure occurs has produced low mortality and morbidity as compared with first operation results. However, unfavorable delays and late rereferral result in mortality rates of up to 22% for emergency redo AVR for degenerated bioprostheses. CONCLUSION: Cardiac surgical units have the opportunity to establish a closer patient-surgeon relationship, which favors, when necessary, the optimal timing of reoperation. Knowledge of the more important risk factors and adherence to specific technical steps at explantation of various devices enhances satisfactory reoperation outcomes.

Aortic Valve↗