PubMed Health⌕ Search

Biomedical subjects

M F Riley

Publications and source records attributed to M F Riley.

At least 19 recordsLinked to original sources

Effect of increased body mass index on accuracy of two-dimensional echocardiography for measurement of left ventricular volume, ejection fraction, and mass.

We used 2- and 3-dimensional echocardiography to determine left ventricular volume, mass, and ejection fraction in overweight (body mass index [BMI] > or = 25 kg/m2), obese (BMI > or = 30 kg/m2), and control (BMI < 25 kg/m2) subjects. Compared with corresponding magnetic resonance imaging measurements, 3-dimensional echocardiography is more accurate than 2-dimensional echocardiography in all patients, but particularly in overweight and obese subjects.

Adult↗

Patient motion compensation during transthoracic 3-D echocardiography.

Bulk patient motion during transthoracic 3-D echocardiography (3DE) produces image plane misregistration and errors in left ventricular (LV) volume and ejection fraction (EF). To correct for patient motion, we used a magnetic locating system to track both the ultrasound transducer and the chest wall of the patient, so images could be registered in a patient-centered coordinate system ("correction"). Fourteen subjects each underwent 3DE, with deliberate patient motion, to measure LV volume and EF. Results were compared to magnetic resonance imaging (MRI). Without correction, 3DE differed significantly from MRI (EF: r = 0.78, SEE = 5.8%). Application of correction increased 3DE accuracy, despite patient motion (EF: r = 0.91, SEE = 3.7%), to a level comparable to that of 3DE in the absence of motion (EF: r = 0.93, SEE = 3.5%). Patient motion during 3DE examination can be corrected using a magnetic spatial location system.

Adult↗

Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction: assessment by two- and three-dimensional echocardiography and magnetic resonance imaging.

OBJECTIVES: This study sought to determine the concordance between biplane and volumetric echocardiography and magnetic resonance imaging (MRI) strategies and their impact on the classification of patients according to left ventricular (LV) ejection fraction (EF) (LVEF). BACKGROUND: Transthoracic echocardiography and MRI are noninvasive imaging modalities well suited for serial evaluation of LV volume and LVEF. Despite the accuracy and reproducibility of volumetric methods, quantitative biplane methods are commonly used, as they minimize both scanning and analysis times. METHODS: Thirty-five adult subjects, including 25 patients with dilated cardiomyopathies, were evaluated by biplane and volumetric (cardiac short-axis stack) cine MRI and by biplane and volumetric (three-dimensional) transthoracic echocardiography. Left ventricular volume, LVEF and LV function categories (LVEF > or =55%, >35% to <55% and < or =35%) were then determined. RESULTS: Biplane echocardiography underestimated LV volume with respect to the other three strategies (p < 0.01). There were no significant differences (p > 0.05) between any of the strategies for quantitative LVEF. Volumetric MRI and volumetric echocardiography differed by a single functional category for 2 patients (8%). Six to 11 patients (24% to 44%) differed when comparing biplane and volumetric methods. Ten patients (40%) changed their functional status when biplane MRI and biplane echocardiography were compared; this comparison also revealed the greatest mean absolute difference in estimates of EF for those subjects whose EF functional category had changed. CONCLUSIONS: Volumetric MRI and volumetric echocardiographic measures of LV volume and LVEF agree well and give similar results when used to stratify patients with dilated cardiomyopathy according to systolic function. Agreement is poor between biplane and volumetric methods and worse between biplane methods, which assigned 40% of patients to different categories according to LVEF. The choice of imaging method (volumetric or biplane) has a greater impact on the results than does the choice of imaging modality (echocardiography or MRI) when measuring LV volume and systolic function.

Adult↗

Three-dimensional echocardiographic measurement of left ventricular mass: comparison with magnetic resonance imaging and two-dimensional echocardiographic determinations in man.

UNLABELLED: This study was performed to compare a novel three-dimensional echocardiography (3DE) system to clinical two-dimensional echocardiography (2DE) and magnetic resonance imaging (MRI) for determination of left ventricular mass (LVM) in humans. LVM is an independent predictor of cardiac morbidity and mortality. Echocardiography is the most widely used clinical method for assessment of LVM, as it is non-invasive, portable and relatively inexpensive. However, when measuring LVM, 2DE is limited by assumptions about ventricular shape which do not affect 3D echo. METHODS: A total of 25 unselected patients underwent 3DE, 2DE and MRI. Three-dimensional echo used a magnetic scanhead tracker allowing unrestricted selection and combination of images from multiple acoustic windows. Mass by quantitative 2DE was assessed using seven different geometric formulas. RESULTS: LVM by MRI ranged from 91 to 316 g. There was excellent agreement between 3DE and MRI (r = 0.99, SEE = 6.9 g). Quantitative 2D methods correlated well with but underestimated MRI (r = 0.84-0.92) with SEEs over threefold greater (22.5-30.8 g). Interobserver variation was 7.6% for 3DE vs. 17.7% for 2DE. CONCLUSIONS: LVM in humans can be measured accurately, relative to MRI, by transthoracic 3D echo using magnetic tracking. Compared to 2D echo, 3D echocardiography significantly improves accuracy and reproducibility.

Adult↗

Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction.

BACKGROUND: Accurate, reproducible, noninvasive determination of left ventricular (LV) volumes and ejection fraction (EF) is important for clinical assessment, risk stratification, selection of therapy, and serial monitoring of patients with cardiovascular disease. Three-dimensional echocardiography (3DE) approaches have demonstrated significantly greater accuracy than current clinical 2DE, but the clinical utility of 3DE has been limited because of the need for substantial modifications to scanning technique (eg, all image acquisition from a single acoustic window) or cumbersome additional hardware. We describe a novel 3DE system without these limitations and its application to patients. METHODS AND RESULTS: Twenty-five patients were examined by 3DE, 2DE, and magnetic resonance imaging (MRI). The 3DE system used a magnetic scanhead tracking device, and volumes were computed with a novel deformable shell model. End-diastolic volumes and EF by MRI ranged from 96 to 375 mL and 18% to 73%, respectively. There was excellent correlation, without statistically significant differences, between MRI and 3DE for end-systolic volume (ESV) (r(2) = 0.99) and end-diastolic volume (EDV) (r(2) = 0.98), ventricular stroke volume (SV) (r(2) = 0.93), and EF (r(2) = 0.97), with standard error estimates less than 10 mL for volumes and 3% for EF. Conventional 2DE consistently underestimated volumes (EDV, P <.01; ESV, P <.01; SV, P <.05); correlations with MRI were r(2) = 0.91 for ESV, r(2) = 0.88 for EDV, r(2) = 0.62 for SV, and r(2) = 0.72 for EF. Standard error estimates ranged from 16 to 20 mL for ventricular volumes and 9% for EF. Interobserver variability was reduced 3-fold with use of 3DE. CONCLUSIONS: The novel 3DE system allows unrestricted selection and combination of acoustic windows in a single examination, improves accuracy of estimates of LV volumes and EF 3-fold compared with 2DE, and is practical for routine clinical assessment of LV size and function in patients with a wide range of cardiac pathology.

Adult↗

Impact of on-line endocardial border detection on determination of left ventricular volume and ejection fraction by transthoracic 3-dimensional echocardiography.

This study was performed to determine whether use of on-line automated border detection (ABD) could reduce data analysis time for 3-dimensional echocardiography (3DE) while maintaining accuracy of 3DE in measures of left ventricular (LV) volumes and ejection fraction (EF). The study proceeded in 2 phases. In the validation phase, 20 subjects were examined with the use of 3DE and of monoplane 2-dimensional (2D) ABD. Results were compared with the reference standard of magnetic resonance imaging (MRI). In the test phase, 20 subjects underwent two 3DE studies (once with images optimized for visual border definition and once with images optimized for ABD border tracking) and a conventionally used 2D ABD study. For 3DE, volumes and EF were determined with the use of manually traced borders and ABD. Analysis times were recorded with a digital stopwatch. In the validation phase, 3DE and MRI results correlated very well (r = 0.99) without systematic differences. Comparison of 2D ABD with MRI showed good correlation for LV volumes (r >/= 0.90) and EF (r = 0.85) despite significant underestimation. For the test phase, Acoustic Quantification-optimized 3-dimensional datasets underestimated end-diastolic volume and EF relative to visually optimized 3-dimensional datasets regardless of whether borders were hand-traced or ABD was used. However, correlations ranged from r = 0.96 to r = 0.98 for LV volumes and 0.88 to 0.91 for LV EF and were superior to those for 2D ABD. Data analysis times decreased moderately with the use of ABD, but scan times increased; total study times were unchanged. Use of on-line ABD with 3DE reduces data analysis time and is more accurate than conventional monoplane 2D ABD but results in underestimation of LV volumes and EF. Additional automated postprocessing techniques may be required to obtain accurate measures, consistently using 3DE in conjunction with on-line ABD.

Adult↗

Three-dimensional echocardiography improves accuracy and compensates for sonographer inexperience in assessment of left ventricular ejection fraction.

This study was performed to determine whether 3-dimensional echocardiography (3DE) with a magnetic tracking system for image plane localization, which unlike standard 2-dimensional echocardiography (2DE), does not require acquisition of specific image planes or "standard views" for quantitative measurement of left ventricular volume and ejection fraction (EF), could compensate for sonographer inexperience. Eight adults underwent magnetic resonance imaging (MRI) scanning; they also had 2DE and 3DE performed by 2 experienced and 3 novice sonographers. Data were analyzed by a single expert reader blinded to patient and sonographer identity. Linear regression of MRI EF (reference standard) against echocardiographic EF yielded the following results, where RD indicates the residual difference between measured MRI values and those predicted using echocardiographic results: expert 3DE: r = 0.97, RD = 2.4%, and r = 0.96, RD = 2.8%; novice 3DE: r = 0. 83, RD = 5.1%, to r = 0.95, RD = 4.8%; expert 2DE: r = 0.85, RD = 4. 8%, and r = 0.86, RD = 4.9%; and novice 2DE: r = 0.34, RD = 11.7%, to r = 0.69, RD = 6.6%. Comparison of error variances indicated that novices who used 3DE equaled the performance of experts who used 2DE, although experts were always more accurate than novices when both used the same echocardiographic method (3DE vs 3DE, 2DE vs 2DE). In a comparison of methods, 3DE was always superior to 2DE, regardless of sonographer experience. Three-dimensional echocardiography allows even novice sonographers to obtain diagnostic-quality data sets, which they were unable to accomplish with 2DE. These results suggest that scanning with 3DE, combined with remote expert interpretation, may be useful in providing echocardiographic services in regions where they are presently unavailable.

Adult↗

Evaluation of left atrial appendage anatomy and function in recent-onset atrial fibrillation by transesophageal echocardiography.

Data regarding left atrial (LA) and LA appendage anatomy and function among patients with newly recognized atrial fibrillation (AF) who have not received long-term warfarin are currently unknown. To identify echocardiographic indexes which characterize those at increased risk for thrombus formation, we analyzed transesophageal echocardiographic studies in 100 consecutive patients with newly recognized AF (duration 2.6 +/- 0.3 week) who had not received long-term warfarin. Fourteen percent of patients had LA thrombi. LA thrombi were associated with larger LA appendages, more depressed LA appendage outflow velocities, and a higher prevalence of severe spontaneous LA contrast. Patients with spontaneous contrast had larger LA and LA appendage anatomy and lower LA appendage ejection velocity. Among patients presenting with their first episode of AF, greater LA appendage ejection and filling velocities and smaller LA and LA appendage sizes were seen among those with AF of <2 weeks duration compared with those with AF of >2 weeks. Thus, patients with recent onset AF and LA thrombi or spontaneous echo contrast have more dilated LA and LA appendage anatomy, and more depressed LA appendage systolic function. Data from patients with their first episode of AF suggests that AF is associated with rapid LA remodeling.

Adult↗

Impaired left atrial mechanical function after cardioversion: relation to the duration of atrial fibrillation.

OBJECTIVES: We hypothesized that the time course of the recovery of atrial systolic function may be related to the duration of atrial fibrillation before cardioversion and sought to study noninvasively the recovery of left atrial mechanical function utilizing serial transthoracic Doppler studies. BACKGROUND: Recovery of atrial mechanical function may be delayed for several weeks after successful cardioversion of atrial fibrillation to sinus rhythm. METHODS: After successful cardioversion, 60 patients with atrial fibrillation of brief (< or = 2 weeks, 17 patients), moderate (> 2 to 6 weeks, 22 patients) or prolonged (> 6 weeks, 21 patients) duration were followed up with serial transmitral pulsed Doppler echocardiography immediately (60 patients) and at 24 h (45 patients), 1 week (41 patients), 1 month (31 patients) and > 3 months (30 patients) after cardioversion. RESULTS: Atrial mechanical function is greater immediately and at 24 h and 1 week after cardioversion in patients with "brief" compared with "prolonged" atrial fibrillation. In all groups, atrial mechanical function increases over time, ultimately achieving similar levels. Full recovery of atrial mechanical function, however, is achieved within 24 h in patients with brief atrial fibrillation, within 1 week in patients with moderate-duration atrial fibrillation and within 1 month in patients with prolonged atrial fibrillation. CONCLUSIONS: Recovery of left atrial mechanical function is related to the duration of atrial fibrillation before cardioversion. These findings have important implications for assessing the early hemodynamic benefit of successful cardioversion.

Adult↗

Remnant of the common pulmonary vein mistaken for a left atrial mass: clarification by transoesophageal echocardiography.

Faulty incorporation of the common pulmonary vein leaves it as a distinct structure posteriorly, into which the pulmonary veins empty. This "chamber" is separated from the anterior "fetal" left atrium (containing the left atrial appendage and communicating with the mitral valve) by a diaphragm, and is known as cor triatriatum, one of the rarest of cardiac malformations. Less pronounced but still incomplete regression of this vein would result in the persistence of a portion of the common pulmonary vein appearing as a mass along the lateral wall of the left atrium at the junction of the left atrial appendage and left upper pulmonary vein. In two patients, both referred for evaluation of a left atrial mass, transoesophageal echocardiography identified the "mass" as a remnant of the common pulmonary vein. Cardiologists need to be aware of this structural remnant and its possible variants so as to avoid misdiagnosis of this prominence as an atrial tumour or mass.

Aged↗

Serial assessment of mitral regurgitation by pulsed Doppler echocardiography in patients undergoing balloon aortic valvuloplasty.

Mitral regurgitation was serially assessed by pulsed Doppler echocardiography in 144 patients undergoing balloon aortic valvuloplasty for symptomatic aortic stenosis. Regurgitant scores of 0, 1, 2 and 3 were assigned to pulsed Doppler patterns corresponding to no, mild, moderate and severe mitral regurgitation, respectively. Before balloon aortic valvuloplasty, mitral regurgitant score correlated significantly (p less than 0.005) but weakly with aortic valve area (r = -0.24), left ventricular ejection fraction (r = -0.34) and left ventricular systolic pressure (r = 0.23). There was no significant correlation between mitral regurgitation and either mean catheterization or mean Doppler aortic valve gradient. Balloon aortic valvuloplasty produced significant decreases in both catheterization and Doppler mean transvalvular aortic valve gradients (56 +/- 19 to 31 +/- 12 and 60 +/- 19 to 48 +/- 16 mm Hg, respectively; both p less than 0.0001) and a significant increase (p less than 0.0001) in aortic valve area assessed by catheterization (0.6 +/- 0.2 to 0.9 +/- 0.3 cm2). Left ventricular ejection fraction did not change, but cardiac output increased (p less than 0.001) and pulmonary capillary wedge pressure decreased (p less than 0.0001). Pulsed Doppler findings of mitral regurgitation were present in 102 of the 144 patients. Eighty-eight patients had a score compatible with mild or more severe degrees of mitral regurgitation, and 49 had a score indicative of moderate or severe valvular insufficiency. In the entire group of 144 patients, mitral regurgitant score decreased significantly from 1.1 +/- 1.0 to 1.0 +/- 1.0 (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Balloon aortic valvuloplasty in 170 consecutive patients.

Between October 1, 1985, and April 1, 1988, we performed balloon aortic valvuloplasty in 170 patients (mean age [+/- SD], 77 +/- 5 years) who had symptomatic aortic stenosis. The procedure was completed successfully in 168 patients and resulted in significant increases in the mean (+/- SD) aortic-valve area (from 0.6 +/- 0.2 to 0.9 +/- 0.3 cm2) and cardiac output (from 4.6 +/- 3.4 to 4.8 +/- 1.4 liters per minute) and decreases in the peak aortic-valve pressure gradient (from 71 +/- 20 to 36 +/- 14 mm Hg) (P less than 0.01 for all three comparisons). There were six in-hospital deaths, and five patients required early aortic-valve replacement. Follow-up data were available for all patients, for a period averaging 9.1 months. In addition to the 6 patients who died in the hospital, 25 patients died an average of 6.4 +/- 5.3 months after discharge. Symptoms recurred in 44 patients; they were managed by repeat valvuloplasty in 16 patients, by aortic-valve replacement in 17, and by medical therapy in 11. At the most recent follow-up examination, the symptoms of 103 patients had improved after valvuloplasty; this number includes 15 patients with restenosis who successfully underwent redilation. Life-table analysis indicates that the probability of survival 12 months after the procedure was 74 percent. We conclude that balloon aortic valvuloplasty is an effective palliative therapy for some elderly patients with symptomatic aortic stenosis. Symptoms improve in the majority of patients; although restenosis is common, it can be managed in some patients by repeat balloon dilation.

Adult↗

Usefulness of noninvasive assessment of aortic stenosis before and after percutaneous aortic valvuloplasty.

Noninvasive and catheterization studies were performed in 40 patients (mean age 76 +/- 12 years) before and after percutaneous aortic valvuloplasty. Measurements included time to 1/2 carotid upstroke, left ventricular ejection time, aortic valve excursion, mean aortic valve gradient and aortic valve area assessed using the continuity equation: aortic valve area = A X V/V1, where A = left ventricular outflow tract area, V = maximal left ventricular outflow tract velocity assessed by pulsed Doppler echocardiography and V1 = peak velocity in the aortic stenotic jet assessed using continuous-wave echocardiography. In addition, mitral regurgitation was assessed by pulsed Doppler mapping techniques. Mean aortic valve gradient, cardiac output and aortic valve area, calculated using the Gorlin formula, were determined at cardiac catheterization. There were significant correlations between Doppler and catheterization measurements of aortic valve area both before (r = 0.71, p less than 0.001) and after (r = 0.85, p less than 0.0001) valvuloplasty. The relations were demonstrated to be linear by F test and met criteria for identity. There were significant increases (all p less than 0.0005) after valvuloplasty in catheterization valve area (0.60 +/- 0.21 to 0.95 +/- 0.39 cm2), Doppler valve area (0.64 +/- 0.22 to 0.91 +/- 0.37 cm2), valve excursion (0.5 +/- 0.3 to 0.8 +/- 0.3 cm) and cardiac output (4.5 +/- 1.6 to 4.9 +/- 1.7 liter/min).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Noninvasive assessment of mitral stenosis before and after percutaneous balloon mitral valvuloplasty.

Thirty-seven patients with symptomatic mitral stenosis underwent balloon dilatation of the mitral valve. Significant increases (p less than 0.001) were noted in both catheterization- and Doppler-determined valve area (0.9 +/- 0.3 to 1.8 +/- 0.8 and 0.9 +/- 0.2 to 1.7 +/- 0.5 cm2). However, catheterization and Doppler areas before and after valvuloplasty correlated less well (r = 0.51, p less than 0.002 and r = 0.47, p less than 0.005, respectively) than the catheterization-Doppler area correlation in a previous study of 59 consecutive patients with varying degrees of mitral stenosis (r = 0.84, p less than 0.001). Mitral valve area increases were independent of valve thickness estimated using 2-dimensional echocardiography. Flail mitral leaflet movement was not observed and the degree of mitral regurgitation qualitatively assessed using pulsed Doppler mapping techniques increased by greater than 1 of 4 grades in only 1 patient. The lateral mitral valve orifice diameter increased more than the anteroposterior diameter, suggesting commissural splitting as the mechanism of successful valvuloplasty. Increases (all p less than 0.0001) were noted in mitral valve EF slope (7 +/- 5 to 18 +/- 10 mm/s), excursion (11 +/- 5 to 13 +/- 4 mm), S20S interval (0.07 +/- 0.02 to 0.08 +/- 0.02 s) and cardiac output (4.2 +/- 1.3 to 5.3 +/- 2.0 liters/min). There were significant decreases (all p less than 0.001) in left atrial diameter (5.4 +/- 1.0 to 5.1 +/- 1.0 cm), mean catheterization gradient (15 +/- 5 to 8 +/- 4 mm Hg) and mean Doppler gradient (10 +/- 4 to 6 +/- 3 mm Hg).(ABSTRACT TRUNCATED AT 250 WORDS)

Catheterization↗

Doppler evidence that true left ventricular-to-aortic pressure gradients exist in hypertrophic cardiomyopathy.

The etiology of systolic left ventricular-to-aortic pressure gradients in hypertrophic cardiomyopathy is still controversial. While cavity obliteration has been proposed by some investigators as the cause for recording of a high left ventricular systolic pressure, the concept of left ventricular outflow tract obstruction has received more experimental support. To investigate further whether left ventricular pressure truly exceeds aortic pressure and implies obstruction, we studied, with imaging and Doppler echocardiographic techniques, five patients with asymmetric septal hypertrophy and systolic anterior movement of the mitral valve occasionally causing it to abut upon the septum. All had outflow tract pressure gradients (peak 85 +/- 10 mm Hg) and trace to mild mitral regurgitation. Continuous wave Doppler study recorded peak flow velocities in the outflow tract (4.6 +/- 0.3 m/sec), and mitral regurgitant (mean 6.6 +/- 0.3 m/sec) jets. Aortic systolic and diastolic blood pressures were measured by cuff sphygmomanometry, and simultaneous carotid pulse tracings were recorded. The magnitude of systolic aortic pressure was determined at the time of peak velocity in the mitral regurgitant jet. Since the peak systolic pressure gradient across the mitral valve (left ventricular minus left atrial pressure) should equal 4 times the square of the peak velocity (V) in the mitral regurgitant jet, peak left ventricular systolic pressure should equal 4 x V2 plus the height of left atrial pressure at the time of peak mitral regurgitant velocity. In each case, calculations were made assuming an upper normal left atrial pressure of 10 mm Hg.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiomyopathy, Hypertrophic↗