PubMed Health⌕ Search

Biomedical subjects

M F Van Oosterhout

Publications and source records attributed to M F Van Oosterhout.

3 recordsLinked to original sources

Optimization of ventricular function by improving the activation sequence during ventricular pacing.

Abnormal electrical activation occurring during ventricular pacing reduces left ventricular (LV) pump function. Two strategies were compared to optimize LV function using ventricular pacing, minimal asynchrony and optimal sequence of electrical activation. ECG and hemodynamics aortic flowprobe, thermodilution cardiac output, LV pressure and its maximal rates of rise (LVdP/dtpos) and fall (LVdP/dtneg) were measured in anesthetized open-chest dogs (n = 7) with healthy hearts. The QRS duration (a measure of asynchrony of activation) was 47 +/- 5 ms during sinus rhythm and increased to 110 +/- 12 ms during DDD pacing at the right ventricular (RV) apex with a short AV interval. During pacing at the LV apex and LV base, the QRS duration was 8% +/- 7% and 15% +/- 7% (P < 0.05) longer than during RV apex pacing, respectively. Stroke volumes, LVdP/dtpos and LVdP/dtneg, however, were higher during LV apex (15% +/- 16%, 10% +/- 12% [P < 0.05], and 15% +/- 10%, respectively) and LV base pacing (11% +/- 12% [P < 0.05], 3% +/- 12%, and 3% +/- 11%, respectively) than during RV apex pacing. Systolic LV pressure was not influenced significantly by the site of pacing. Biventricular pacing (RV apex together with one or two LV sites) decreased the QRS duration by approximately 20% as compared with RV apex pacing, however, it did not improve stroke volumes, LVdP/dtpos and LVdP/dtneg beyond those during pacing at the LV apex alone. In conclusion, the sequence of electrical activation is a stronger determinant of ventricular function than the synchrony of activation. For optimal LV function the selection of an optimal single pacing site, like the LV apex, is more important than pacing from multiple sites.

Animals↗

Fluorescent microspheres are superior to radioactive microspheres in chronic blood flow measurements.

The accuracy of the fluorescent (FM) and radioactive microsphere (RM) techniques is similar in acute experiments but has not been established in chronic experiments. In the present study various combinations (at least pairs) of FM and/or RM labels were injected simultaneously between 2 mo and 5 min before each animal was killed. Blood flow was determined in many organs. Intramethod mean difference and variation did not change over time for FM but increased significantly for RM (from 1.8 +/- 1.4 to 25.6 +/- 21.8% and from 4.4 +/- 3.2 to 32.4 +/- 23.0% at 5 min and 2 mo, respectively). Also the FM-RM intermethod mean difference and variation increased (from -0.5 +/- 8.5 to 40.8 +/- 23.8% and from 23. 6 +/- 4.6 to 71.8 +/- 34.3%, respectively). After 2 mo, blood flow estimations were 20-50% lower with the various RM, whereas brain and liver blood flow values varied even more between isotopes. Underestimation started within 1 day for 51Cr and within 2 wk for 141Ce, 95Nb, and 85Sr. We conclude that FM are superior to RM for blood flow determination in experiments lasting longer than 1 day, presumably because of leaching of isotopes from RM.

Animals↗

Fluorescent microspheres to measure organ perfusion: validation of a simplified sample processing technique.

A disadvantage of nonradioactive microsphere techniques is that the processing of samples is time-consuming and complex. We developed and validated a simplified processing method for the fluorescent microsphere (FM) technique. In seven anesthetized dogs with coronary artery stenosis up to six different FM and five different radioactivity labeled microspheres (RM) were injected. Two FM and two RM labels were injected simultaneously to enable inter- and intramethod comparison. After gamma-counting samples of blood, myocardium (n = 168), and other organs (n = 59) were digested in test tubes with 2 N ethanolic KOH (60 degrees C, 48 h), microspheres were sedimented by centrifugation, dye was extracted in the same tube, and fluorescence was measured. With this processing method, recovery of FM was approximately 100%. Good correlations for inter- and intramethod comparisons were found [r = 0.985 +/- 0.01 (mean +/- SD)]. The lower intermethod correlation for blue microspheres (r = 0.958) indicates that the use of this label is less desirable. RM and FM endocardial-to-epicardial blood flow ratios correlated well (r = 0.974). With this one-vessel centrifugal sedimentation method and at least five fluorescently labeled microspheres, blood flow can be reliably measured in various organs, including ischemic myocardium.

Animals↗