PubMed Health⌕ Search

Biomedical subjects

M Faraggi

Publications and source records attributed to M Faraggi.

At least 19 recordsLinked to original sources

[Is sentinel node biopsy feasible in endometrial cancer? Results in 26 patients].

OBJECTIVES: To evaluate detection rate, topography and false negatives of sentinel lymph node in endometrial cancer. MATERIAL AND METHODS: Twenty-six patients were included. Lymphoscintigraphy was performed the day before surgery. Preoperative detection of the sentinel lymph node was performed with cervical blue dye injection and a gamma probe. Separate pathology examinations were performed for sentinel and non-sentinel lymph nodes. Sentinel lymph nodes were examined with hematoxylin-eosin-safran stain, and immunohistochemistry if negative. RESULTS: Twenty-six patients had a positive lymphoscintigraphy. Preoperative detection was successful in 21 patients (80.8%): the detection rate with isotopic method, 19 cases (73.1%), was superior to the dye detection, 15 cases (57.7%). No isolated lombo-aortic sentinel lymph nodes were observed, and all sentinel lymph nodes were in the ilio-obturator region. Seven patients presented lymphatic spread, and 4 of them had at least one sentinel node. There was one micrometastasis in sentinel node, associated with isolated tumoral cells in pelvic lymphadenectomy. There was no false negative of sentinel node. CONCLUSION: The biopsy of sentinel lymph node is a feasible procedure in endometrial cancer. There was one micrometastatic sentinel node. However there was no isolated lomboaortic sentinel lymph node in this study.

Adenocarcinoma↗

Prognostic value of radionuclide angiography in patients with right ventricular arrhythmias.

BACKGROUND: The prognosis of patients with right ventricular (RV) arrhythmias remains uncertain. This study prospectively evaluated the prognostic value of RV and left ventricular (LV) involvement assessed by radionuclide angiography (RNA) as predictors for sudden death. METHODS AND RESULTS: Patients (n=188) with severe arrhythmias originating from the RV were followed up for a mean of 45+/-34 months. Data on clinical presentation, resting and stress ECG, signal-averaged ECG, 24-hour Holter monitoring, and programmed stimulation were collected along with RNA. Patients were classified as group I (n=82) with normal RNA or group II (n=106) with an abnormal RV suggestive of arrhythmogenic RV cardiomyopathy, classified as diffuse or localized disease, with or without associated LV abnormalities. During follow-up, 14 patients died suddenly, all in group II. None of the clinical and electrical data were predictive of death. An abnormal RNA study was a highly predictive factor for death (P<0.005), as well as the presence of LV abnormalities (P<0.01). CONCLUSIONS: The present study confirms that arrhythmogenic RV cardiomyopathy is a severe disease with a high risk for cardiac death. Evidence of RV abnormalities in patients presenting with RV arrhythmias is highly predictive for sudden death, as is its association with LV involvement.

Adolescent↗

Myocarditis in patients with clinical presentation of myocardial infarction and normal coronary angiograms.

OBJECTIVES: The aim of this study was to assess the diagnosis of myocarditis in patients presenting with acute myocardial infarction (MI) and normal coronary angiograms. BACKGROUND: Most often in these patients, the etiologic diagnosis remains unclear once they are found to have normal coronary arteries. The diagnosis of myocarditis mimicking MI is clinically relevant, because numerous arguments suggest a relation between myocarditis and dilated cardiomyopathy. Myocardial indium-111 (111In)-antimyosin antibody (AMA)/rest thallium-201 (201Tl) imaging allows noninvasive detection of myocarditis. METHODS: Forty-five patients admitted to three intensive care units for suspicion of acute MI, with normal coronary angiograms, were investigated. Indium-111-AMA planar images and then a dual-isotope rest AMA/201Tl tomographic study were performed. Six-month echocardiographic follow-up was obtained in 80% of the patients with initial left ventricular (LV) wall motion abnormalities. RESULTS: In eight patients, AMA and 201Tl scintigraphy were negative. In two patients, a matched 201Tl defect and focal AMA uptake suggested acute MI (due to prolonged vasospasm or spontaneously reperfused coronary occlusion). In 17 patients, diffuse AMA uptake over the whole LV suggested diffuse myocarditis. In 18 patients, focal AMA uptake with a normal 201Tl scan suggested diffuse but heterogeneous, or focal myocarditis. Complete functional recovery was observed in 81% of the patients with a pattern of myocarditis. CONCLUSIONS: Among 45 patients presenting with acute MI and normal coronary angiograms, 38% had diffuse myocarditis and 40% had a scintigraphic pattern of heterogeneous or focal myocarditis. Short-term follow-up showed complete LV functional recovery in 81% of these patients.

Adult↗

Prognostic value of 201Tl myocardial scintigraphy after coronary artery bypass grafting.

BACKGROUND: 201Tl myocardial scintigraphy (201Tl SPECT) is of strong prognostic value in various populations with suspected or known coronary artery disease. However, its value in patients with coronary artery bypass grafting (CABG) is not fully assessed. METHODS: We examined 115 consecutive patients to determine the relation between clinical data/stress 201Tl SPECT performed 5+/-3 years after CABG, and subsequent cardiac events. RESULTS: Thirteen patients (11%) had stress-induced angina, 22 (19%) had electrical positivity, and 97 (84%) had abnormal scintigraphy, including 62 (54%) with reversible defects. During follow-up (35+/-22 months), there were nine cardiac deaths, seven myocardial infarctions, and 20 revascularization procedures. Multivariate Cox analysis identified the delay between CABG and scintigraphy (P<0.01, relative risk (RR) = 1.01), the extent of stress 201Tl defects (P = 0.04, RR = 1.18), and increased stress 201Tl lung uptake (P = 0.03, RR = 3.56) as significant predictors of cardiac deaths/infarctions. Delay between CABG and scintigraphy (P < 0.001, RR = 1.01), the extent of stress 201Tl defects (P = 0.03, RR = 1.15), and that of reversible defects (P = 0.05, RR = 1.13) were the only significant predictors of total events. CONCLUSIONS: Besides the delay between CABG and scintigraphy, the scintigraphic parameters were the only significant and additive predictors of cardiac events in 115 patients with CABG.

Adult↗

Somatostatin receptor scintigraphy and gallium scintigraphy in patients with sarcoidosis.

UNLABELLED: Somatostatin receptor scintigraphy (SRS) has been shown to reveal sarcoidosis sites. The aim of this study was to prospectively compare SRS and gallium scintigraphy in the evaluation of pulmonary and extrapulmonary involvement in patients with proven sarcoidosis. METHODS: Eighteen patients with biopsy-proven sarcoidosis were included. Nine were or recently had been receiving steroid therapy at the time of the examination. Planar gallium scintigraphy (head, chest, abdomen, and pelvis) and thoracic SPECT were performed at 48-72 h after injection of a mean dose of 138 +/- 21 MBq 67Ga. Planar SRS and thoracic SPECT were performed at 4 and 24 h after injection of a mean dose of 148 +/- 17 MBq 111n-pentetreotide. RESULTS: Gallium scintigraphy found abnormalities in 16 of 18 patients (89%) and detected 64 of 99 clinically involved sites (65%). SRS found abnormalities in 18 of 18 patients and detected 82 of 99 clinically involved sites (83%). Of the 9 treated patients, gallium scintigraphy found abnormalities in 7 (78%), detecting 23 of 39 clinically involved sites (59%), whereas SRS found abnormalities in 9, detecting 32 of 39 clinically involved sites (82%). CONCLUSION: This study suggests that, compared with gallium scintigraphy, SRS appears to be accurate and contributes to a better evaluation of organ involvement in sarcoidosis patients, especially those treated with corticosteroids.

Adrenal Cortex Hormones↗

[Evaluation of the ejection fraction tomoscintigraphy synchronised with an electrocardiogram].

Electrocardiographic gated myocardial scintigraphy (gated SPECT) allows simultaneous evaluation of left ventricular perfusion and contractility. The aim of this study was to assess the impact of the type of tracer and temporal sampling on the measurement of the ejection fraction by gated SPECT. Eighty-six consecutive patients (59 men, 27 women, average age 62 +/- 11 years) with a history of myocardial infarction (anterior N = 50--inferior N = 36) were studied. All had measurement of the isotopic ejection fraction by equilibrium angioscintigraphy and by gated SPECT sampled at 8 (N = 45, 52%) or 16 images/cycle RR (N = 41, 48%). After filtered retroprojection, the ejection fraction was calculated by a validated method (QGS). A better correlation between gated SPECT and equilibrium angioscintigraphy was observed at 16 images/cycle (r = 0.90) compared with 8 (r = 0.80). The Bland-Altman curves showed improved accuracy of the measurement of the ejection fraction by gated SPECT with 16 compared with 8 images/cycles sampling (mean differences of 0.37 +/- 6.06% and 4.3 +/- 7.71%, respectively). Multivariable analysis showed that temporary sampling was the only parameter to significantly affect the difference between the two methods. There was no difference between the use of Thallium and that of 99mTc-sestamibi. Gated SPECT, therefore, provides an accurate measurement of the ejection fraction for routine clinical usage, providing the acquisition is made at 16 images/cycle.

Electrocardiography↗

Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation.

UNLABELLED: The current major limitation to development of electrocardiographically (ECG) gated blood-pool SPECT (GBPS) for measurement of the left ventricular (LV) ejection fraction (LVEF) and volumes is the lack of availability of clinically validated automatic processing software. Recently, 2 processing software methods for quantification of the LV function have been described. Their LVEFs have been validated separately, but no validation of the LV volume measurement has been reported. METHODS: We compared 3 processing methods for evaluation of the LVEF (n = 29) and volumes (n = 58) in 29 patients: automatic geometric method (GBPS(G)), semiautomatic activity method (GBPS(M)), and 35% maximal activity manual method (GBPS(35%)). The LVEF provided by the ECG gated equilibrium planar left anterior oblique view (planar(LAO)) and the LV volumes provided by LV digital angiography (Rx) were used as gold standards. RESULTS: Whereas the GBPS(G) and GBPS(M) methods present similar low percentage variabilities, the GBPS(35%) method provided the lowest percentage variabilities for the LVEF and volume measurements (P < 0.04 and P < 0.02, respectively). The LVEF and volume provided by the 3 methods were highly correlated with the gold standard methods (r > 0.98 and r > 0.83, respectively). The LVEFs provided by the GBPS(35%) and GBPS(M) methods are similar and higher than those of the GBPS(G) method and planar(LAO) method, respectively (P < 0.0001). For the LVEF, there is no correlation between the average and paired absolute difference for the 3 GBPS methods against the planar(LAO) method, and the limits of agreement are relatively large. LV volumes are lower when calculated with the GBPS(M), GBPS(G), and Rx methods (P < 0.0001). However, the GBPS(35%) and Rx methods provide LV volumes that are similar. There is no linear correlation between the average and the paired absolute difference of volumes calculated with the GBPS(G) and GBPS(35%) methods against Rx LV volumes. However, a moderate linear correlation was found with the GBPS(M) method (r = 0.6; P = 0.0001). The 95% limits of agreement between the Rx LV volumes and the 3 GBPS methods are relatively large. CONCLUSION: GBPS is a simple, highly reproducible, and accurate technique for the LVEF and volume measurement. The reported findings should be considered when comparing results of different methods (GBPS vs. planar(LAO) LVEF; GBPS vs. Rx volume) and results of different GBPS processing methods.

Electrocardiography↗

Clinical impact of combination of scatter, attenuation correction, and depth-dependent resolution recovery for (201)Tl studies.

UNLABELLED: A lack of specificity for myocardial perfusion imaging has been widely reported, mostly related to false-positive defects on the inferior wall. The application of depth-dependent resolution recovery (RR), attenuation correction (AC) using external source devices, and scatter correction has been proposed to resolve this pitfall. METHODS: We studied the clinical benefit of depth-dependent RR, nonuniform AC using a scanning line source, and scatter correction (photon energy recovery [PER]) compared with filtered backprojection alone. Eighty-two patients were included: 40 healthy volunteers with a low likelihood of coronary artery disease (control group) and 42 patients with proven right or circumflex coronary artery disease but without involvement of the left anterior descending artery. Among these 82 patients, the images of 33 were also processed with PER. RESULTS: RR did not alter the performance of filtered backprojection alone. AC + RR greatly improved specificity and the rate of normal (201)Tl SPECT findings in the control population (from 56% to 95% and from 53% to 100%, respectively) but significantly decreased sensitivity (from 92% to 54%). AC + RR generated a false anteroapical defect in 21% of patients and reverse redistribution of the apex in 23%. AC + RR significantly decreased the extent of the stress defect (from 4.09 to 3.21 segments, P < 0.003) and increased the perfusion score of the stress defect (from 0.78 +/- 0.72 to 1.47 +/- 1.11, P < 0.00061). Moreover, AC + RR generated overcorrection on the inferior wall, leading to false estimation of viability for 11 of 15 patients with an old inferior myocardial scar without evidence of residual viability. PER decreased overcorrection on the inferior wall, but without improving sensitivity. PER did not significantly reduce the number of anteroapical false-positives or the number of apical reverse distribution cases. CONCLUSION: AC + RR improved the specificity and normalcy rate of (201)Tl SPECT myocardial perfusion imaging but generated overcorrection on the inferior wall, leading to low sensitivity and to false evaluation of myocardial viability in 73% of the patients with inferior infarction. AC + RR also generated anteroapical artifacts. The addition of scatter correction did not significantly reduce these drawbacks.

Coronary Circulation↗

Reperfusion syndrome: relationship of coronary blood flow reserve to left ventricular function and infarct size.

OBJECTIVES: We tested the hypothesis that the reperfusion syndrome (RS), defined as an additional elevation of the ST segment upon reperfusion, may be a marker of microcirculatory reperfusion injury during acute myocardial infarction (AMI). BACKGROUND: The pathophysiology of the RS is unknown, and its prognostic implications are controversial. METHODS: Twenty-one patients with an anterior AMI treated < or =12 h after onset by primary coronary angioplasty (PTCA) were studied. Coronary velocity reserve (CVR), an index of microcirculatory function, was measured using a Doppler guidewire. Left ventricular (LV) ejection fraction, infarct size (percent defect) and LV end-systolic volume index (LVESVi) were evaluated by radionuclide ventriculography, 201T1 single-photon emission computed tomography and contrast ventriculography, respectively. RESULTS: Baseline ST elevation and pain-to-TIMI 3 time were similar in patients with and without RS. Patients with RS (10/21) had a lower post-PTCA CVR than patients without RS (median [95% confidence interval]: 1.2 [1-1.3] vs. 1.6 [1.5-1.7], p < 0.005). Even though predischarge CVR was similar in the two groups, infarct size at six weeks (26 [21 to 37] vs. 14 [10-17]% 201T1 defect, p = 0.001) and predischarge LVESVi (45% [40 to 52] vs. 30% [29 to 38] mL/m2, p = 0.001) were larger, and LV ejection fraction at six weeks (40% [37 to 46] vs. 55% [50 to 60], p = 0.004) was lower in patients with RS than in patients without RS. CONCLUSIONS: Patients with RS during primary PTCA for an anterior AMI have a transiently lower CVR than patients without RS, but sustained LV dysfunction and larger infarct size, suggesting that RS is a marker of microcirculatory reperfusion injury.

Aged↗

Relationship between resting 201Tl reverse redistribution, microvascular perfusion, and functional recovery in acute myocardial infarction.

UNLABELLED: 201TI reverse redistribution is a common finding early after reperfusion therapy for myocardial infarction. Its mechanism and clinical implications remain unclear. The aim of this study was to clarify the relationships between reverse redistribution, microvascular perfusion, and myocardial viability. METHODS: Resting, 10-min-postinjection, and redistribution 201TI data obtained for 33 patients 8 and 42 d after the onset of acute myocardial infarction were compared with echocardiographic wall motion measured acutely and on day 42. Microvascular perfusion was assessed by myocardial contrast echocardiography performed 10 min after restoration of complete patency of the infarct artery. RESULTS: Marked significant reverse redistribution was found on day 8 (absolute change, 7.5%+/-7.9% of the 10-min-postinjection defect size; P<5x0.000001) and significantly decreased on day 42 (2.7%+/-6.8%; P = 0.004 between days 8 and 42). The 10-min-postinjection defect size best predicted the final infarct size on day 42 and was closely related to microvascular perfusion. Patients with adequate reperfusion had a smaller postinjection defect on day 8 (21.1%+/-14.6%) and a larger reverse redistribution (10.2%+/-6.1%) than did patients with no reflow (35.3%+/-13% and 3.2%+/-9.2%, respectively; P<0.04 for both). CONCLUSION: Reverse redistribution was marked early after myocardial infarction in patients with complete patency of the infarct artery and decreased in subsequent weeks. Reverse redistribution was associated with restoration of adequate microvascular reperfusion and with myocardial salvage and viability. The early postinjection scans on day 8 were the relevant images for assessing myocardial salvage and predicting wall motion recovery.

Coronary Circulation↗

Diagnosis of extensive coronary artery disease: intrinisic value of increased lung 201 T1 uptake with exercise SPECT.

UNLABELLED: Exercise lung 201 TI uptake calculated with planar imaging has an important diagnostic and prognostic value in patients with coronary artery disease (CAD). However, its value with SPECT imaging raises methodological concerns and is controversial. We studied its value for the discrimination between extensive (E) and limited (L) angiographic CAD with exercise SPECT. METHODS: Four methods of lung-to-heart ratio quantification were calculated in patients with a low likelihood (< 5%) of CAD (n = 62). Their dependent variables were defined, and corresponding correction equations were derived. Receiver operating characteristic (ROC) analysis was performed in a pilot group (L-CAD, n = 49; E-CAD, n = 126) to define the optimal method of calculation of the lung-to-heart ratio. Its best threshold providing the best sensitivity for a specificity of 90% was defined. After correction for dependent variables, the 4 methods were also compared by ROC analysis and the optimal corrected method was compared with the optimal uncorrected method using ROC analysis and the best threshold. The consistency of these results in the validation group (L-CAD, n = 41; E-CAD, n = 122) and of the results of visual analysis of lung 201TI uptake were then verified. RESULTS: On ROC analysis in the pilot group, the optimal method of calculation of the lung-to-heart ratio was the mean activity in a region of interest drawn at the base of the lungs to the mean activity over the heart (Lb/H). For the best threshold, Lb/H presented a sensitivity of 34%. Corrected Lb/H still remained the best method of calculation on ROC analysis compared with the other corrected methods. On ROC analysis, there was no difference between corrected and uncorrected Lb/H. For the best threshold, corrected Lb/H presented a similar sensitivity of 37% compared with uncorrected Lb/H. When applied to the validation group (L-CAD, n = 41; E-CAD, n = 122), the best-defined threshold in the pilot group for corrected Lb/H presented a diagnostic value similar to that in the pilot group (sensitivity, 41%; specificity, 90%), but uncorrected Lb/H presented a higher sensitivity (47%; P < 0.04) and a slightly lower specificity (80%). Results of lung 201TI uptake visual analysis were inconsistent between pilot and validation groups (42% versus 58% sensitivity, P = 0.012; 86% versus 66% specificity, P = 0.023). CONCLUSIONS: For evaluation of E-CAD versus L-CAD, quantification of the exercise lung-to-heart 201TI uptake ratio with SPECT is feasible, reproducible, more discriminate than simple visual analysis, and best calculated as Lb/H. It presents an intrinsic diagnostic value even after correction for other clinically valuable dependent variables.

Case-Control Studies↗

Cell irradiation caused by diagnostic nuclear medicine procedures: dose heterogeneity and biological consequences.

Most radionuclides used for diagnostic imaging emit Auger electrons (technetium-99m, iodine-123, indium-111, gallium-67 and thallium-201). Their very short range in biological tissues may lead to dose heterogeneity at the cellular level with radiobiological consequences. This report describes the dosimetric models used to calculate the mean dose absorbed by the cell nucleus from Auger radionuclides. The techniques used to determine the biodistribution of radiopharmaceuticals at the subcellular level are also described and compared. Published examples of cellular dosimetry computations performed with radiotracers are reviewed in various clinical settings. Finally, the biological implications of the subcellular localization of Auger emitters are examined. While a number of efforts have been made to obtain dosimetric models and to estimate subcellular distribution of radioactivity, little is known of the cellular dosimetry of most radiopharmaceuticals used in diagnostic imaging. However, biological examples of selective radiotracer uptake have been shown, leading to extremely strong cell-cell dose heterogeneity. Furthermore, radiobiological experiments show that the biological effects of Auger emitters incorporated into DNA can be severe, with relative biological effectiveness greater than 1 compared with external X-rays. These findings clearly show that the assessment of biological risks associated with internal administration of diagnostic radiopharmaceuticals must focus not only on target organs as a whole, but also on the cellular level. This review proposes the most appropriate model for dosimetric computations (cellular or conventional) according to the subcellular distribution of radiotracers. The radionuclide of choice and the general strategy used to design new diagnostic radiopharmaceuticals are also discussed.

Humans↗

Decreased no-reflow in patients with anterior myocardial infarction and pre-infarction angina.

AIMS: Pre-infarction angina is associated with better outcome after myocardial infarction. The aim of this study was to assess whether pre-infarction angina is associated with decreased no-reflow after coronary recanalization. METHODS AND RESULTS: Twenty-three patients underwent intracoronary myocardial contrast echocardiography during the acute phase of anterior myocardial infarction after successful recanalization, and before hospital discharge. Myocardial perfusion was graded semi-quantitatively in the area at risk (dyssynergic segments). Global left ventricular function was assessed by radionuclide angiography on days 8 and 42 and regional wall motion was assessed by 2D echocardiography on days 0 and 42. Fourteen patients had pre-infarction angina (angina less than 7 days before myocardial infarction) and nine did not. Baseline characteristics were similar in the two groups. The myocardial contrast echocardiography perfusion score in the area at risk after recanalization was higher in the patients with pre-infarction angina than in those without (0.72 +/- 0.19 vs 0.53 +/- 0.22, P=0.04), and the incidence of no-reflow (myocardial contrast echocardiography perfusion score < or =0.5) was lower (14% vs 56%, P=0.04). This difference persisted 8 +/- 2 days after myocardial infarction (0. 87 +/- 0.11 vs 0.69 +/- 0.26, P=0.04), and was associated with greater mid-term (day 42) improvement in left ventricular function in patients with pre-infarction angina than in those without, as assessed by changes in radionuclide left ventricular ejection fraction (+5.8 +/- 8.1% vs -3.3 +/- 4.6%, respectively;P=0.01) and by changes in regional wall motion score on 2D echocardiography (-0. 61 +/- 0.39 vs -0.24 +/- 0.17, respectively;P=0.04). CONCLUSION: Pre-infarction angina is associated with preservation of the microvasculature, reflected by reduced no-reflow. This may be a mechanism underlying greater recovery of left ventricular function in patients with pre-infarction angina.

Adult↗

111Indium antimyosin antibody imaging of primary myocardial involvement in systemic diseases.

OBJECTIVE: The diagnosis of primary myocardial involvement in systemic diseases is clinically relevant but difficult in the absence of specific criteria. Whatever the underlying disease, myocytes degeneration is observed during the active phase of myocardial damage. The aim of this study was to assess the diagnostic value of scintigraphic imaging with 111Indium antimyosin antibody (AM), a specific marker of the damaged myocyte, for ongoing myocardial damage related to systemic diseases. METHODS: 40 patients with histologically confirmed systemic diseases were studied. They were classified into two groups according to the presence (group 1, n = 30), or the absence (group 2, n = 10) of clinical, electrocardiographic (ECG) or echocardiographic signs suggestive of myocardial involvement. Planar and tomographic acquisitions were obtained 48 hours after injection of AM (90 MBq). Rest 201thallium (T1) scintigraphy was also performed to assess myocardial perfusion and scarring. Clinical, ECG, and echocardiographic +/- scintigraphic evaluations were repeated during follow up (17 +/- 19 months) in 36 of 40 patients. RESULTS: In group 1, 13 of 30 patients (43%) showed diffuse significant AM uptake throughout the left ventricle (LV), and no or mild T1 abnormality. Two of these were asymptomatic, four had normal ECG, and two had no clinical or echographic LV dysfunction. All patients in group 2 had negative AMA scintigraphy and normal T1 scintigraphy. During follow up of 12 AM positive patients, cardiac status improved after immunosuppressive treatment was intensified in nine cases, worsened in two cases, and remained stable in one. During follow up of 24 AM negative patients, cardiac status remained stable in 23 cases despite treatment not being increased in 20, including two patients with sequellary myocardial involvement. The last patient developed mild LV dysfunction after 36 months. CONCLUSION: AM scintigraphy allows detection of active myocardial damage related to systemic diseases, with increased specificity compared with conventional methods, and increased sensitivity in some cases. Further studies are needed to assess the potential value of AM scintigraphy as a therapeutic guide.

Adult↗

Acute assessment of microvascular perfusion patterns by myocardial contrast echocardiography during myocardial infarction: relation to timing and extent of functional recovery.

OBJECTIVE: To examine the relation between the initial microvascular perfusion pattern, as assessed by intracoronary myocardial contrast echocardiography (MCE), immediately after restoration of TIMI (thrombolysis in myocardial infarction) (TIMI) grade 3 flow during acute myocardial infarction, and the extent and timing of functional recovery in the area at risk. SETTING: Referral centre for interventional cardiology. METHODS: Intracoronary MCE was performed 15 minutes after TIMI grade 3 recanalisation of the infarct artery in 25 patients. Segmental myocardial contrast patterns were graded semiquantitatively (0, none; 0.5, heterogeneous; 1, homogeneous). Functional recovery was assessed by echocardiography on days 9 and 42. RESULTS: Among 174 myocardial segments in the area at risk, wall motion recovery on day 9 was observed in 40% of MCE grade 1 segments but there was no significant recovery in grade 0 or 0.5 segments. On day 42, recovery had occurred in 56% of MCE grade 1 segments (p < 0. 0001 v MCE grade 0 and 0.5; p = 0.0001 v MCE grade 1 on day 9), and 22% of MCE grade 0.5 segments (p = 0.02 v MCE grade 0; p = 0.0005 v MCE grade 0.5 on day 9); MCE grade 0 segments did not recover. Negative predictive value in predicting recovery by contrast enhancement was 95% and 89% by days 9 and 42, respectively. CONCLUSIONS: Contractile recovery occurs earliest in well reperfused segments. Up to one quarter of segments with heterogeneous contrast enhancement show wall motion recovery within the first six weeks. Myocardial perfusion after recanalisation in acute myocardial infarction, even if heterogeneous, is a prerequisite for postischaemic functional recovery. Thus preservation of acute myocardial perfusion is associated with more complete and early functional recovery.

Adult↗

Spontaneous late improvement of myocardial viability in the chronic infarct zone is possible, depending on persistent TIMI 3 flow and a low grade stenosis of the infarct artery.

OBJECTIVE: In the chronic phase of myocardial infarction, the relation between myocardial recovery and infarct related artery status remains unclear. The spontaneous changes in rest-redistribution thallium defect size were prospectively studied over six months in 52 patients with chronic Q wave myocardial infarction. DESIGN: Changes in rest thallium defect size, thallium uptake in the infarct area, and radionuclide left ventricular ejection fraction were compared to the quantitative coronary angiogram data. Two groups of patients were considered: patients with a percentage of stenosis below 100% (group 1, n = 31); and patients with an occluded artery (group 2, n = 21). RESULTS: In the overall population, the mean (SD) defect size decreased from 28.2 (17.2)% to 24.9 (19.3)% of the whole myocardium (p = 0.01), while, in this area, the thallium uptake increased from 62.9 (13.7)% to 66. 9 (15.6)% (p < 0.001). At the time of inclusion, the defect size, thallium uptake, and ejection fraction were similar in both groups. In group 1 patients only, the reduction in defect size correlated with the improvement in ejection fraction (r = 0.41, p = 0.02) and was related to the percentage of coronary artery stenosis. TIMI 3 patients reduced the defect size while other patients increased this defect (-5.1 (7.0)% v +11.0 (14.4)%, p < 0.001). In contrast, no significant relations were found in group 2 patients. CONCLUSION: Late spontaneous recovery in thallium defect can occur in patients with a patent infarct related artery, depending on the TIMI flow grade and a low grade stenosis of the infarct related artery, and is associated with functional improvement.

Aged↗