PubMed Health⌕ Search

Biomedical subjects

M Faschingbauer

Publications and source records attributed to M Faschingbauer.

7 recordsLinked to original sources

[A sizeable chance--surgical management of profound obesity concurrent with post-traumatic osteoarthrosis].

In times of plentiful nutrition an environmental advantage turns into a problem - obesity. Apart from an increase in morbidity and overall mortality the development of osteoarthrosis is well documented. Pre-arthrotic conditions may arise from trauma and can lead, depending on the pattern of injury, to full-blown arthrosis. The presence of obesity can play the role of a relevant progressive factor in this setting. Here we report about the case of an obese man (BMI 53.5 kg/m(2)), who suffered a fracture of the femoral head with acetabular participation (Pipkin IV) as well as a fracture of the tibial plateau. Operative management and rehabilitation were followed by gastric bypass surgery for weight reduction. The case is discussed with regard to the present literature.

Adult↗

Locked vs. unlocked plate osteosynthesis of the proximal humerus - a biomechanical study.

BACKGROUND: Locked plates (internal fixators) have been found to be an optimal method for the fixation in proximal humeral fractures. In a biomechanical cadaver study the difference between locked and non-locked osteosyntheses was investigated. METHODS: Paired humeri were harvested, bone density measured. Locked internal fixators were mounted on one specimen; identical plate-screw-systems without locking mechanism applied to the contralateral specimen for comparison. After that, a transverse subcapital osteotomy was performed. With 7 pairs of humeri static tests with increasing axial loads and with 5 pairs dynamic tests with 10 N preload and 80 N maximal axial load for up to 1 million cycles were performed. RESULTS: In the static experiments the elastic stiffness of the construct was 74% higher in the locked group (median 80 N/mm, quartile range 77-86 N/mm) compared with the non-locked group (46 N/mm, 35.5-56.5 N/mm). The difference was statistically significant (Wilcoxon test for paired samples, P<0.05). Similarly, the linear range until failure was definitely extended in the locked group by 64% (92 N, 89-98 N vs. 56 N, 36.5-73.5 N, P<0.05). Under dynamic loading the non-locked group showed fixation failures between 97,000 and 500,000 cycles. In the locked group no failure was observed until the end of the experiment at 1 million cycles (P<0.0.5). The final deformation was found to be 1 mm (median, quartil range 1.0-1.2 mm) in the non-locked group and 0.3 mm (0.2-0.3 mm) in the locked group (P<0.05). The differences were found equally in lower as well as in higher bone density specimen. INTERPRETATION: Because of the optimal load transfer between implant and cancellous bone, a locked screw plate interface will reduce fixation failure in proximal humeral fractures.

Biomechanical Phenomena↗

[Spontaneous fracture of the tibia after replacement of the anterior cruciate ligament with absorbable interference screws. A case report and review of the literature].

We report a granulomatous inflammatory reaction after administration of absorbable interference-fit screws for fixation of patellar-tendon-autograft in anterior-cruciate-ligament reconstruction, leading to spontaneous fracture of the tibia. Radiological evaluation demonstrated osteolytic lesions at the interference-fit screw insertion-site. Histological findings included a sterile inflammatory reaction and giant-cell formation.

Absorbable Implants↗

[The transparent tibia].

To keep damage to vascular and neural structure in the lower leg to a minimum when Ilizarov ring fixators are mounted, a transparent model of the lower leg has been designed and produced. In this model the course of the vascular and neural structures is shown anatomically correct relative to the bones of the lower leg. This model makes it easier to imagine the spatial relations and helps in correct placement of the Kirschner wires in the lower leg.

Arteries↗

[Treatment of chronic osteitis of the femur].

Since May 1990, we have treated seven patients with chronic osteomyelitis of the femur. The Ilisarov apparatus was used in three of these cases for fixation and in four cases for segment transport. The treatment of four patients is now complete. We have not found any problems in bone regeneration. The use of pins in the proximal and middle thirds of the femur has proved problematic due to the soft tissue damage. Instead of this, we recommend using Schanz screws, which can be fixed to the arch with the AO lock. Moreover, it is easier to shorten the 180 degrees arch to 90 degrees or 120 degrees using the Schanz screws. To prevent problems, it is better to assemble the apparatus before use and to take into consideration the anatomical and functional situation.

Adult↗