An empirical technique to compensate for melanin when monitoring skin microcirculation using reflectance spectrophotometry.

Errors can occur in measuring blood content and oxygenation in subjects with significant skin pigmentation using reflectance spectrophotometry. The melanin in the epidermis not only reduces the amount of back-scattered light, but also has a characteristic absorption spectrum that varies between individuals. Skin color is primarily influenced by the concentration of melanin, blood content and oxygenation in the superficial microvasculature. A three-step process was developed empirically to accommodate the effect of melanin in the absorption spectrum of skin. A melanin index was developed and applied for each individual tested. Spectral components attributable specifically to melanin were subtracted from the measured spectrum, and its amplitude was normalized. This technique was tested with 26 able-bodied subjects with different levels of skin pigmentation. The melanin-compensated spectra from pigmented and caucasian skin were indistinguishable and no correlation was found between calculated values for indices of blood content and oxygenation, and melanin index.

Algorithms

Assessment of skin blood content and oxygenation in spinal cord injured subjects during reactive hyperemia.

This study was undertaken to determine whether the reactive hyperemia response following ischemia in spinal cord injured (SCI) individuals is different from that which occurs in able-bodied (AB) individuals. The reactive hyperemia response was produced by applying a pressure of 150 mmHg for 300 s, 600 s, and 900 s to the skin over the greater trochanter in 10 SCI and 10 AB subjects using a computer-controlled pneumatic indentation system. The changes in blood content and oxygenation in the superficial vessels of the skin, associated with indentation, were monitored using reflectance spectrophotometry. A brief pressure of 80 mmHg, to simulate finger pressing (blanching), was applied to the same site to detect changes in reflow behavior during the hyperemic period. The results indicate that the reactive hyperemia response in SCI group was not substantially different from AB group although the reflow rate after load release was slower in the SCI group compared with the AB group.

Adult

A skin indentation system using a pneumatic bellows.

A pneumatic indentation system using a copper bellows has been developed for physiological studies where a controlled uniaxial compressive force is required to be applied to the surface of the skin. Such a system is useful for studies where the physiological response of the tissues is to be monitored following a known loading history. The indentation system is driven by a vacuum/compression pneumatic pump through solenoid valves under closed-loop computer control. A load cell placed between the indentor and bellows monitors the applied force providing a feedback signal to the computer. The signal from the computer activates the valves supplying air pressure to the bellows, and the applied force is controlled using a digital closed-loop protocol. This system can be used to provide a controlled loading sequence to the skin without utilizing gravitational forces, which allows the subject to keep a more natural position during the experiment.

Equipment Design

Biochemical changes in sweat following prolonged ischemia.

Much emphasis has been placed on the measurement of physical parameters at the body support interface in order to detect and moderate conditions which could result in pressure damage to soft tissues. Major difficulties are encountered both in the design of instrumentation and interpretation of the data collected. Metabolic processes in sweat glands that control sweat secretion have been shown to be sensitive to applied pressure, producing sweating rate suppression and changes in sweat NaCl concentration. In this study, we have demonstrated the feasibility of measuring lactate concentration in sweat collected locally using an electrochemical stimulation technique (iontophoresis of pilocarpine nitrate). Elevated levels of sweat lactate concentration during local tissue indentation were detected in a group of able-bodied subjects. Upon removal of the indentor, however, levels of sweat lactate returned to normal.

Adult

Development of a modular wheelchair cushion for spinal cord injured persons.

This paper discusses a modular wheelchair cushion system intended for patients at moderate or low risk for developing pressure sores. With the use of components with different mechanical and physical properties the modular cushion produces improved performance compared with cushions comprising the individual components alone. In addition to achieving clinically acceptable interface pressures, this approach to wheelchair cushion prescription helps to accommodate individual preferences associated with stability, temperature dissipation, and resiliency. Mechanical tests were performed to demonstrate the underlying principles of the modular cushion. Tests with able-bodied subjects identified specific cushion configurations for different weight groups, offering alternative material configurations that may be selected at the discretion of the therapist or patient.

Body Weight

Q-switched Ruby laser treatment of black tattoos.

The use of a Q-switched pulsed Ruby laser was studied in removing tattoos. The results were very satisfactory, but there are several major disadvantages which at present would probably preclude the use of this therapy on a routine basis.

Dermatologic Surgical Procedures

Seating the disabled.