The un-physiology of peritoneal dialysis solution and the peritoneal membrane: from basic research to clinical nephrology.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Feriani.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The side effects of glucose degradation products (GDPs) in conventional peritoneal dialysis (PD) fluids are well described. Using the three-compartment bag concept--that is, in situ preparation of concentrated glucose solution into a standard ionic solution--a GDP-free solution can be processed. To investigate the possible impact of this product on biological and clinical parameters, we carried out a prospective cross-over study with 31 patients, comparing the short-term effects of conventional PD and GDP-free PD solutions. Classical peritoneal parameters and ultrafiltration rate did not change during the study. After three months and after six months with the three-compartment bag, cancer antigen 125 (CA125) concentration in overnight fluid increased significantly (p < 0.001) from 24.4 IU/mL to 44.4 IU/mL and 41.1 IU/mL respectively. CA125 decreased significantly (p < 0.01) to 21.7 IU/mL after three months with the conventional solution. No change in hyaluronan concentration was observed. A slight increase of procollagen III N-terminal peptide in overnight effluent with the GDP-free solution was followed by a significant reduction after three months with standard solution. In summary, our data show that the GDP-free PD fluid improves mesothelial cell mass and turnover even after a short-term period of three months. A better quality of PD solution is obtained by using the three-compartment bag.
BACKGROUND: Over the past 15 years, lactate has been used successfully as a buffer in peritoneal dialysis solutions, although its effectiveness in the correction of uremic acidosis and its biocompatibility on peritoneal resident cells have been questioned. In addition, some investigators have suggested other potential adverse metabolic effects resulting from the unphysiologically high lactate flux into the body during CAPD. These potential problems associated with lactate-containing CAPD solution prompted the search for alternative buffer-containing solutions. Bicarbonate, the physiological buffer, was considered when the problem of calcium and magnesium carbonate solubility was solved by the use of a two-compartment bag system, allowing the mixing of bicarbonate and divalent cations immediately before infusion. The long-term tolerance, safety, efficacy and therapeutic value of a bicarbonate-buffered peritoneal dialysis solution were evaluated in this study. METHODS: This open, randomized, controlled, multicenter study comparing a 34 mmol/liter bicarbonate- with a 35 mmol/liter lactate-buffered peritoneal dialysis solution was performed in two consecutive 12-week-treatment phases. Fourteen Centers participated in this trial. RESULTS: A total of 69 out of initially 123 randomized patients completed the six-month study period (36 patients in the bicarbonate group and 33 in the lactate group). While the arterial acid base status of the total study population did not change during the study period and no significant difference was observed between the two treatment groups, the acid-base status of patients in the bicarbonate group entering the study with a metabolic acidosis significantly improved (mean +/- SD; blood pH: baseline = 7.361 +/- 0.05, week 12 = 7.380 +/- 0.04, P < 0.05; week 24 = 7.388 +/- 0.03 P < 0.05; plasma bicarbonate: baseline = 19.49 +/- 3.01 mmol/liter, week 12 = 21.16 +/- 2.63 mmol/liter, P < 0.01; week 24 = 21.51 +/- 2.42 mmol/liter, P < 0.01). No significant changes were recorded in acidotic patients treated with the conventional lactate-buffered solution. The changes in plasma bicarbonate from baseline during the study was significantly different between the groups (week 12: lactate = +0.11 +/- 2.21 mmol/liter, bicarbonate = +1.69 +/- 2.55 mmol/liter, P < 0.05, 95% confidence interval for the difference 0.21 to 2.94 mmol/liter; week 24: lactate = +0.03 +/- 2.48 mmol/liter, bicarbonate = +1.82 +/- 2. 96 mmol/liter, P < 0.05, 95% confidence interval for the difference 0.16 to 3.42 mmol/liter). The normalized protein catabolic rate (nPCR) slightly but significantly decreased in the lactate group (baseline -0.90 +/- 0.23 g/kg/day, week 24 -0.83 +/- 0.21 g/kg/day, P < 0.01) and increased in the bicarbonate group (baseline +0.89 +/- 0.28 g/kg/day, week 24 +0.92 +/- 0.26 g/kg/day, P < 0.05). Changes from baseline between groups were significant (week 24, lactate = -0. 099 +/- 0.15 g/kg/day, bicarbonate = 0.049 +/- 0.12 g/kg/day, P < 0. 01, 95% confidence interval for the difference 0.068 to 0.229 g/kg/day). Other evaluated parameters (biochemical profile, peritoneal function parameters, dialysate protein loss) did not differ significantly between the two groups. No adverse effects related to the study solution were recorded. CONCLUSIONS: These results support the efficacy and safety of bicarbonate-buffered peritoneal solutions in a controlled randomized comparison for up to six months. Peritoneal dialysis solutions containing the physiological buffer bicarbonate might effectively replace conventional lactate-buffered CAPD solutions.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Our objective is to investigate transperitoneal buffer fluxes with solution containing lactate and bicarbonate, and to compare the final effect on body base balance of the two solutions. One hundred and four exchanges, using different dwell times, were performed in 52 stable continuous ambulatory peritoneal dialysis (CAPD) patients. Dialysate effluent lactate and bicarbonate and volumes were measured. Net dialytic base gain was calculated. Patients' acid-base status and plasma lactate were determined. In lactate-buffer CAPD solution, lactate concentration in dialysate effluent inversely correlated with length of dwell time, but did not correlate with plasma lactate concentration and net ultrafiltration. Bicarbonate concentration in dialysate effluent correlated with plasma bicarbonate and dwell time but not with ultrafiltration. The arithmetic sum of the lactate gain and bicarbonate loss yielded the net dialytic base gain. Ultrafiltration was the most important factor affecting net dialytic base gain. A previous study demonstrated that in patients using a bicarbonate-buffered solution the net bicarbonate gain is a function of dwell time, ultrafiltration, and plasma bicarbonate. By combining the predicted data of the dialytic base gain with the calculated metabolic acid production, an approximate body base balance could be obtained with both lactate- and bicarbonate-buffered CAPD solutions. The body base balance in CAPD patients is self-regulated by the feedback between plasma bicarbonate concentration and dialytic base gain. The level of plasma bicarbonate is determined by the dialytic base gain and the metabolic acid production. This can explain the large interpatient variability in acid-base correction. Bicarbonate-buffered CAPD solution is equal to lactate solution in correcting acid-base disorders of CAPD patients.
Explore the source record for details and available documents.