Evaluation of a new electromagnetic tracking system using a standardized assessment protocol.

This note uses a published protocol to evaluate a newly released 6 degrees of freedom electromagnetic tracking system (Aurora, Northern Digital Inc.). A practice for performance monitoring over time is also proposed. The protocol uses a machined base plate to measure relative error in position and orientation as well as the influence of metallic objects in the operating volume. Positional jitter (E(RMS)) was found to be 0.17 mm +/- 0.19 mm. A relative positional error of 0.25 mm +/- 0.22 mm at 50 mm offsets and 0.97 mm +/- 1.01 mm at 300 mm offsets was found. The mean of the relative rotation error was found to be 0.20 degrees +/- 0.14 degrees with respect to the axial and 0.91 degrees +/- 0.68 degrees for the longitudinal rotation. The most significant distortion caused by metallic objects is caused by 400-series stainless steel. A 9.4 mm maximum error occurred when the rod was closest to the emitter, 10 mm away. The improvement compared to older generations of the Aurora with respect to accuracy is substantial.

Austria↗

Fast DRR generation for 2D/3D registration.

We present a simple and rapid method for generation of perspective digitally rendered radiographs (DRR) for 2D/3D registration based on splat rendering. Suppression of discretization artefacts by means of computation of Gaussian footprints--which is a considerable computational burden in classical splat rendering--is replaced by stochastic motion of either the voxels in the volume to be rendered, or by simulation of a X-ray tube focal spot of finite size. The result is a simple and fast perspective rendering algorithm using only a small subset of voxels. Our method generates slightly blurred DRRs suitable for registration purposes at framerates of approximately 10 Hz when rendering volume images with a size of 30 MB on a standard PC.

Algorithms↗

Risk analysis and safety assessment in surgical robotics: a case study on a biopsy robot.

One of the most important issues in medical robotics is safety and integration into the clinical workflow. If a robot is not safe and its use is complicated by difficult handling and complex user interfaces physicians would not use a robotic system during clinical patient trials, whatever the other advantages are. However, there are only few publications on this topic, in particular on risk management in developing a robotic prototype (for clinical trials). In this paper risk management and the safety of using robot-assisted surgery equipment are discussed and demonstrated exemplarily in the process of developing a prototype biopsy robot.

Journal Article↗

Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems.

This study aims to provide a quantitative analysis of the factors affecting the actual precision and stability of optoelectronic and electromagnetic tracking systems in computer-aided surgery under real clinical/intraoperative conditions. A "phantom-skull" with five precisely determined reference distances between marker spheres is used for all measurements. Three optoelectronic and one electromagnetic tracking systems are included in this study. The experimental design is divided into three parts: (1) evaluation of serial- and multislice-CT (computed tomography) images of the phantom-skull for the precision of distance measurements by means of navigation software without a digitizer, (2) digitizer measurements under realistic intraoperative conditions with the factors OR-lamp (radiating into the field of view of the digitizer) or/and "handling with ferromagnetic surgical instruments" (in the field of view of the digitizer) and (3) "point-measurements" to analyze the influence of changes in the angle of inclination of the stylus axis. Deviations between reference distances and measured values are statistically investigated by means of analysis of variance. Computerized measurements of distances based on serial-CT data were more precise than based on multislice-CT data. All tracking systems included in this study proved to be considerably less precise under realistic OR conditions when compared to the technical specifications in the manuals of the systems. Changes in the angle of inclination of the stylus axis resulted in deviations of up to 3.40 mm (mean deviations for all systems ranging from 0.49 to 1.42 mm, variances ranging from 0.09 to 1.44 mm), indicating a strong need for improvements of stylus design. The electromagnetic tracking system investigated in this study was not significantly affected by small ferromagnetic surgical instruments.

Biophysical Phenomena↗