PubMed Health⌕ Search

Biomedical subjects

M Franciosi

Publications and source records attributed to M Franciosi.

6 recordsLinked to original sources

Self-monitoring of blood glucose in non-insulin-treated diabetic patients: a longitudinal evaluation of its impact on metabolic control.

AIMS: In the framework of a nationwide outcomes research programme, we assessed the impact of self-monitoring of blood glucose (SMBG) on metabolic control over 3 years in patients with Type 2 diabetes mellitus (DM2) not treated with insulin. METHODS: The study involved 1896 patients who completed, at 6-month intervals for 3 years, a questionnaire investigating SMBG practice. Clinical information was collected by participating clinicians at the same time intervals. The predictive value of SMBG frequency on long-term metabolic control was estimated using multilevel analysis. The impact of SMBG on metabolic control was also evaluated in distinct and homogeneous subgroups of patients showing different likelihood of performing SMBG, identified using a tree-growing technique (RECPAM). RESULTS: Overall, 22% of the patients were on diet alone and 78% were treated with oral agents; 41% practiced SMBG > or = 1/week (10.3% > or = 1/day). The analysis of metabolic control according to the frequency of SMBG failed to show any significant impact of this practice on HbA1c levels over 3 years. Similarly, changes in SMBG frequency during the study were not related to significant changes in HbA1c levels. RECPAM analysis led to the identification of eight classes, characterized by substantial differences in the likelihood of performing SMBG with a frequency of at least 1/week. Nevertheless, in none of the RECPAM classes identified, did SMBG predict a better metabolic control over 3 years of follow-up. In those RECPAM classes indicating that SMBG was mainly performed to avoid hypoglycaemic episodes, SMBG was associated with a decrease in the frequency of hypoglycaemic episodes during the study. CONCLUSIONS: In a large sample of non-insulin-treated Type 2 diabetic patients, the performance and frequency of SMBG did not predict better metabolic control over 3 years. We could not identify any specific subgroups of patients for whom SMBG practice was associated with lower HbA1c levels during the study.

Algorithms↗

Randomized trial of 2 versus 5 years of adjuvant tamoxifen for women aged 50 years or older with early breast cancer: Italian Interdisciplinary Group Cancer Evaluation Study of Adjuvant Treatment in Breast Cancer 01.

PURPOSE: To compare 2 with 5 years of adjuvant tamoxifen therapy in the treatment of early breast cancer. PATIENTS AND METHODS: Women with breast carcinoma T1-3, N0-3, M0, who were between 50 and 70 years of age, were eligible irrespective of menopausal status, tumor grade, or estrogen receptor (ER) status. Patients who were event-free after 2 years of tamoxifen therapy were randomly assigned to stop or continue tamoxifen therapy for an additional 3 years. The primary end point was length of disease-free survival (DFS). Secondary end points included overall survival (OS) and toxicity. RESULTS: From 1989 through 1996, 1,901 patients were randomly assigned either to stop treatment (n = 958) or to receive tamoxifen for 3 additional years (n = 943). The median duration of postrandomization follow-up was 52 months. We found no statistically significant differences between the 5-year arm and the 2-year arm in terms of DFS (hazard ratio [HR], 0.91; 95% confidence interval [CI], 0.76 to 1.08) and OS (HR, 1.16; 95% CI, 0.92 to 1.46). In ER-positive patients, a statistically significant prolongation of DFS related to longer treatment duration was observed (HR, 0.74; 95% CI, 0.59 to 0.93), whereas no difference in OS could be detected (HR, 0.98; 95% CI, 0.72 to 1.32). No differences in terms of endometrial cancers, cardiac or cerebrovascular events, or fractures were detected, whereas a doubling in the risk of thromboembolic events was found in the 5-year arm. CONCLUSION: Our results confirm previous research that shows that 5 years of tamoxifen decreases recurrence compared to 2 years in patients with ER-positive tumors.

Aged↗

Alternative site blood glucose testing: a multicenter study.

The aim of this study was to compare glucose measurements between fingertip and forearm using the blood glucose (BG) monitoring system One Touch Ultra (LifeScan), an electrochemical sensor that requires only a very small drop of blood (1 microL). Patients with type 1 or type 2 diabetes were identified in five outpatient diabetes clinics. Participants were requested to use the One Touch Ultra at home for 1 week for the measurement of BG levels from both sites. Patients filled in a questionnaire about their experience with testing blood samples from fingertip and forearm. The agreement between the measurements from the two sites was assessed using linear regression analysis, mean absolute relative error (MARE), the Bland-Altman method, and Error Grid Analysis (EGA). Overall, 112 patients were recruited, of whom 58% had type 1 diabetes. Linear regression analysis showed an intercept of 17.7, statistically different from 0 (p<0.0001). The slope was 0.956, and the Pearson correlation coefficient was 0.95. A MARE of 12.1% (SD=11.8%) was obtained, with a greater deviation of the forearm values from the fingertip ones in the hypoglycemic range (MARE=22.3%; SD=21.7%). The Bland-Altman bias plot showed a mean bias of 10.2 mg/dL (SD=23.1), with no correlation between mean difference and average BG levels (r=0.02). The EGA showed that 89.2% of the values fell in zone A, 10.4% in zone B, and 0.4% in zone C. The vast majority of patients (71%) declared that the collection of blood from the forearm caused no pain or less pain than the traditional site. Only 17% of the patients declared that it was impossible to obtain any blood from the forearm, while 63% reported with satisfaction that the quantity requested was small. At the end of the study period, 32% of the participants indicated the forearm as the preferred test site. Alternative site testing on the arm, with a BG meter that requires only a very small drop of blood, is feasible and reliable under routine clinical conditions. When testing with the express purpose of detecting hypoglycemia, the finger still remains the recommended test site.

Adolescent↗

The impact of blood glucose self-monitoring on metabolic control and quality of life in type 2 diabetic patients: an urgent need for better educational strategies.

OBJECTIVE: The role of self-monitoring of blood glucose (SMBG) in type 2 diabetes is still a matter of debate. In the framework of a nationwide outcomes research program, we investigated the frequency of SMBG and its association with metabolic control and quality of life (QoL). RESEARCH DESIGN AND METHODS: The study involved 3,567 patients with type 2 diabetes who were recruited by 101 outpatient diabetes clinics and 103 general practitioners. Patients completed a questionnaire investigating SMBG practice and QoL (diabetes-related stress, diabetes health distress, diabetes-related worries, and Centers for Epidemiologic Studies-Depression scale). RESULTS: Data on SMBG were available for 2,855 subjects (80% of the entire study population). Overall, 471 patients (17%) stated that they tested their blood glucose levels at home > or =1 time per day, 899 patients (31%) tested their blood glucose levels > or =1 time per week, and 414 patients (14%) tested their blood glucose levels <1 time per week, whereas 1,071 patients (38%) stated that they never practiced SMBG. A higher frequency of SMBG was associated with better metabolic control among subjects who were able to adjust insulin doses, whereas no relationship was found in all other patients, irrespective of the kind of treatment. Multivariate analyses showed that an SMBG frequency > or =1 time per day was significantly related to higher levels of distress, worries, and depressive symptoms in non-insulin-treated patients. CONCLUSIONS: Our findings suggest that SMBG can have an important role in improving metabolic control if it is an integral part of a wider educational strategy devoted to the promotion of patient autonomy. In patients not treated with insulin, self-monitoring is associated with higher HbA(1c) levels and psychological burden. Our data do not support the extension of SMBG to this group.

Ambulatory Care Facilities↗

The relationship between physicians' self-reported target fasting blood glucose levels and metabolic control in type 2 diabetes. The QuED Study Group--quality of care and outcomes in type 2 diabetes.

OBJECTIVE: To investigate the relationship between beliefs of physicians relative to intensive metabolic control in type 2 diabetes and levels of HbA1c obtained in a sample of their patients. RESEARCH DESIGN AND METHODS: Physicians' beliefs were investigated through a questionnaire sent to a sample of self-selected clinicians participating in a nationwide initiative aimed at assessing the relationship between the quality of care delivered to patients with type 2 diabetes and their outcomes. At the same time, physicians were asked to collect clinical data on a random sample of their patients, stratified by age (<65 vs. > or = 65 years). Mean HbA1c levels in the study population were thus evaluated according to target fasting blood glucose (FBG) used by their physicians. RESULTS: Of 456 physicians, 342 (75%) returned the questionnaire. Among the responders, 200 diabetologists and 99 general practitioners (GPs) recruited 3,297 patients; 2,003 of whom were always followed by the same physician and 1,294 of whom were seen by different physicians in the same structure on different occasions. Only 14% of the respondents used target FBG levels < or = 6.1 mmol/l, whereas 38% pursued values >7.8 mmol/l, with no statistically significant difference between diabetologists and GPs. The analysis of the relationship between FBG targets and metabolic control, restricted to those patients always seen by the same physician, showed a strong linear association, with mean HbA1c values of 7.0 +/- 1.6 for patients in the charge of physicians pursuing FBG levels < or = 6.1 mmol/l and 7.8 +/- 1.8 for those followed by physicians who used target values >7.8 mmol/l. After adjusting for patients' and physicians' characteristics, the risk of having HbA1c values > 7.0% was highly correlated with physicians' beliefs. Patients followed by different physicians in the same unit showed a risk of inadequate metabolic control similar to that of patients followed by physicians adopting a nonaggressive policy. CONCLUSIONS: Doctors adopt extremely heterogeneous target FBG levels in patients with type 2 diabetes, which in turn represent an important independent predictor of metabolic control. To improve patient outcomes, physicians-centered educational activities aimed at increasing the awareness of the potential benefits of a tight metabolic control in patients with type 2 diabetes are urgently needed.

Aged↗

The effectiveness, safety and epidemiology of the use of acarbose in the treatment of patients with type II diabetes mellitus. A model of medicine-based evidence.

OBJECTIVE: To assess the efficacy, safety and extent of perceived indications of acarbose, a new antidiabetic agent, under routine clinical practice conditions in an unselected Northern Italian population of type II diabetic patients. METHODS: The study population was assigned to three different groups according to the physician's clinical judgement: group A (acarbose considered as an elective treatment); group B (acarbose considered to be of uncertain benefit): group C (acarbose deemed not to be appropriate). Group B patients were randomized either to continue their standard treatment or to add acarbose to it. Patients with type II diabetes mellitus were recruited from 17 diabetes outpatient clinics from one Italian region (Lombardy). A total of 1027 patients were recruited (group A: 283; group C: 494; group B: 250, of whom 124 were randomly assigned to standard treatment + acarbose and 126 to standard treatment alone). Acarbose was administered for 1 year at a median dose of 100 mg 3 times daily. Drug efficacy was evaluated in terms of mean HbAlc, pre- and post-prandial glycaemic values. Additional endpoints were the proportion of patients with HbA1c levels below 8% at the end of the study period and the proportion of subjects who needed a modification in the standard treatment. The safety and tolerability profiles of the drug were also investigated. Data on HbA1c, fasting and post-prandial blood glucose levels were analysed over time using repeated-measures analysis [Generalized Estimating Equation (GEE) models]. RESULTS: The analysis of Group B showed that, after treatment for 1 year, the mean reduction in HbA1c levels in the acarbose group with respect to the control group was 0.30% (95% confidence limits -0.60 +0.02; P = 0.07), while the mean reduction in post-prandial glycaemia was 17 mg-dl(-1) (95% c.l. -33.5 -0.8; P = 0.04). No difference resulted for fasting blood glucose levels. When looking at the baseline HbA1c levels, it emerged that the mean benefit associated with the use of acarbose was 0.14% (95% c.l. -0.6 +0.28; P = 0.5) in patients with HbAlc levels below 8%, 0.28% (95% c.l. -0.6 +0.05; P = 0.09) in those with values between 8% and 9.9% and 0.65% (95% c.l. -1.36 +0.06; P = 0.07) in those with values > or =10%. Only patients treated with diet+/-oral anti-diabetic agents (OAA) benefited from acarbose treatment (mean benefit = 0.37%, 95% c.l. -0.65 -0.08), while no effect was shown for insulin-treated subjects. The proportion of patients with HbA1c below 8% increased from 31% to 44% in the acarbose group and from 40% to 45% in the control group (absolute difference between baseline and end-of-study values = 8.0% in favour of acarbose-treated patients; P = 0.058). Patients treated with acarbose were significantly more likely to undergo a dose reduction in concomitant diabetic treatments compared with the control group; they were also less likely to require an increase in the dose of standard treatment and to start insulin during the study period. One third of the patients could not assume the drug for the whole study period, mainly due to gastrointestinal side-effects. CONCLUSIONS: The design adopted in this study allowed an integrated evaluation of the overall effectiveness of acarbose in clinical practice. The benefits of the drug in an unselected population of non-insulin-dependent diabetes mellitus (NIDDM) patients are significant but of marginal clinical relevance. Only a better definition of the subgroups of patients who are more likely to benefit from long-term treatment, particularly through possible postponement of secondary OAA failure, will allow a reliable definition of the cost-effectiveness of this complementary component of anti-diabetic strategy.

Acarbose↗