PubMed Health⌕ Search

Biomedical subjects

M Francoeur

Publications and source records attributed to M Francoeur.

15 recordsLinked to original sources

Inhaled nitric oxide in acute respiratory distress syndrome: a pilot randomized controlled study.

This pilot randomized controlled clinical trial of patients with ARDS was implemented to study the impact of inhaled nitric oxide (inhNO) on lung function, morbidity, and mortality. Thirty patients with ARDS were randomly allocated to usual care or usual care plus inhNO. The optimal dose of inhNO was determined to be between 0.5 and 40 parts-per-million daily. All therapeutic interventions were standardized. ARDS resulted mainly from sepsis (25 of the 30). During the first 24 h, the hypoxia score increased greatly in patients treated with inhNO +70.4 mm Hg (+59%) versus +14.2 mm Hg (+9.3%) for the control group (p = 0.02), venous admixture decreased from 25.7 to 15.2% in the inhNO group, and from only 19.4 to 14.9% in the control group (p = 0.05). After the first day of therapy no further beneficial effect of inhNO was detected. Forty percent of the patients treated with inhNO were alive and weaned from mechanical ventilation within 30 d after randomization compared with 33.3% in the control group (p = 0.83). The 30-d mortality rate was similar in the two groups; most deaths (11 of 17) were due to multiple organ dysfunction syndrome. This study shows that inhNO, in this population, may improve gas exchange but does not affect mortality.

Administration, Inhalation↗

Inhaled nitric oxide: clinical applications, indications, and toxicology.

PURPOSE: Although the analogy of nitric oxide (NO) to Endothelium-derived Relaxing Factor remains controversial, medical use of exogenous NO gas by inhalation has grown exponentially. This review presents the mechanisms of action of inhaled NO in pulmonary hypertension, hypoxaemia, inflammation and oedema, as well as its therapeutic and diagnostic indications with emphasis on acute respiratory distress syndrome (ARDS) and toxicology. SOURCE: Two medical databases (Current Contents, Medline) were searched for citations containing the above-mentioned key words to December 1996. Moreover, many presentations in congresses such as 4th International Meeting of Biology of Nitric Oxide, 52nd and 53rd Annual Meeting of Canadian Anaesthetists' Society or 10th Annual Meeting of European Association of Cardiothoracic Anaesthesiologists were used. PRINCIPAL FINDINGS: Inhaled NO is now recognized as an invaluable tool in neonatal and paediatric critical care, and for heart/lung surgery. Other clinical applications in adults, such as chronic obstructive pulmonary disease and ARDS, require a cautious approach. The inhaled NO therapy is fairly inexpensive, but it would seem that it is not indicated for everybody with regards to the paradigm of its efficiency and potential toxicity. The recent discovery of its anti-inflammatory and extrapulmonary effects open new horizons for future applications. CONCLUSION: Clinical use of inhaled NO was mostly reported in case series, properly designed clinical trials must now be performed to establish its real therapeutic role. These trials would permit adequate selection of the cardiopulmonary disorders, and subsequently the patients that would maximally benefit from inhaled NO therapy.

Administration, Inhalation↗

Impact of nitric oxide on blood pressure in hemodialysis patients.

Nitric oxide (NO) is a powerful vasoactive agent that contributes to the regulation of blood pressure (BP). However, the role of NO in uremic patients and during the course of hemodialysis is still debated. Blood L-arginine concentrations and exhaled NO concentrations were measured in 22 healthy controls and in 22 hemodialysis patients before and after dialysis. On the basis of their BP response during hemodialysis, the patients were divided into three groups: 6 of the 22 patients presented with a decrease in BP during dialysis (group 1), eight presented with a stable BP (group 2), and eight with an increase in BP (group 3). The exhaled NO concentration was higher in dialysis patients than in healthy controls (22.7 +/- 2.6 ppb in dialysis patients v 16.7 +/- 0.9 ppb in controls, mean +/- SEM, P = 0.044). The predialysis and postdialysis exhaled NO concentrations were inversely correlated with the change in BP during hemodialysis (r = -0.47, P = 0.013). Patients with a decrease in BP (group 1) had the highest NO concentrations; patients with an increase in BP (group 3) had the lowest values; and patients with a stable BP during the course of dialysis (group 2) had intermediary values (trend test, P = 0.0291). In addition, both the exhaled NO concentration and the blood L-arginine concentration decreased during dialysis in all patients (P = 0.005 and P = 0.001, respectively). These results provide several novel insights into NO metabolism and BP regulation during hemodialysis: (1) maintenance hemodialysis is associated with a chronic increase in NO concentrations; (2) changes in BP during hemodialysis are inversely correlated with exhaled NO concentrations, higher NO levels being associated with a decrease in BP and lower NO levels with an increase in BP during dialysis; (3) blood L-arginine levels decrease during hemodialysis, and this reduction may in turn influence NO production.

Adult↗

Extra-pulmonary effects of inhaled nitric oxide in swine with and without phenylephrine.

We have compared the effects of inhaled nitric oxide (iNO) and i.v. nitroglycerin (ivGTN) on the haemodynamic response to phenylephrine-induced hypertension (PEHT) in anaesthetized pigs. PEHT did not change either pulmonary vascular resistance or gas exchange throughout all experiments. Both treatments lowered pulmonary arterial pressure to the same extent (-12.4% iNO; -13.7% ivGTN) and passively via an effect on left atrial pressure (-26.3% iNO; -31.4% ivGTN). Both treatments failed to reverse the decrease in renal blood flow (RBFc) induced by PEHT, but both increased urinary flow (UF) (+128% iNO; +148% ivGTN). IvGTN significantly increased plasma concentrations of nitrite and nitrate during (+22.7% arterial blood; +26.2% venous blood) and beyond the period of infusion (iNO: +6.4% and +4.9%, respectively). In four control pigs (no PEHT), iNO markedly increased RBFc (+109%), glomerular filtration rate (+72.5%) and UF (+68.7%). We conclude that iNO may have direct cardiac and renal effects, probably via intervention of NO carrier forms such as S-nitroso compounds.

Administration, Inhalation↗

Effects of reducing reagents and temperature on conversion of nitrite and nitrate to nitric oxide and detection of NO by chemiluminescence.

To measure the concentration of nitrites and nitrates by chemiluminescence, we examined the efficiency of five reducing agents [V(III), Mo(VI) + Fe(II), NaI, Ti(III), and Cr(III)] to reduce nitrite (NO2-) and (or) nitrate (NO3-) to nitric oxide (NO). The effect of each reducing agent on the conversion of different amounts of NO2- and (or) NO3- (100-500 pmol, representing concentrations of 0.4 to 2 mu molar) to NO was determined at 20 degrees C for NO2- and at 80 degrees C for NO3-. The effect of temperature from 20 to 90 degrees C on the conversion of a fixed amount of NO2- or NO3- (400 pmol or 1.6 mu molar) to NO was also determined. These five reducing agents are similarly efficient for the conversion of NO2- to NO at 20 degrees C. V(III) and Mo(VI) + Fe(II) can completely reduce NO3- to NO at 80 degrees C. NaI and Cr(III) were unable to convert NO3- to NO. Increased temperature facilitated the conversion of NO3- to NO, rather than that of NO2- to NO. We evaluated the recovery of NO2- and NO3- from plasmas of pig and of dog. Recovery from plasma of both animals was reproducible and near quantitative.

Animals↗

Comparison of two administration techniques of inhaled nitric oxide on nitrogen dioxide production.

The purpose of this study was to verify whether, compared with the introduction of the NO-N2 mixture at the air inlet of the ventilator (classical method), a direct injection of NO-N2 into the inspiratory line of the ventilator circuit with a new injection device (new method), would reduce NO2 formation by reducing contact time between O2 and NO. The effect of two FIO2(0.21 and 0.90) and NO concentrations on NO2 production was determined. In the classical method, NO and O2 were mixed with an air/oxygen blender before the gas mixture entered the ventilator. In the new method, NO was injected directly into the respiratory line with the injection system. Nitric oxide and nitrogen dioxide gases were measured using a chemiluminescence analyzer. For a FI02 of 0.90 and 90 ppm of NO2, the amount of NO2 produced was decreased from 8.9 +/- 0.8 ppm (mean +/- SD) with the classical injection system to 4.4 +/- 0.2 ppm with the new injection system (P = 0.0039, Mann-Whitney test), and NO2 production was decreased from 4.5 +/-0.2 ppm to 2.1 +/- 0.4 ppm (P = 0.02) at 60 ppm of NO. However, at a FIO2, no difference was found in the amount of NO2 produced. We conclude that, compared with the classical method of NO administration, the new NO injection system reduces considerably the concentration of inhaled NO2 when a high FIO2 and a high concentration of NO are used.

Administration, Inhalation↗

Estimation of C3 levels in cerebrospinal fluid by electroimmunodiffusion.

C3 levels have been determined by the electroimmunodiffusion technique in the CSF of patients with a wide variety of pathologies. The patients were grouped on the basis of protein content and G/A ratio of the CSF as I) patients with normal meningeal permeability and apparent absence of local gamma-globulin synthesis; II) patients with increased meningeal permeability; III) patients with characteristics of MS, i.e. increase of IgG accompanied by a normal or slightly elevated protein content, Group III showed a lower level of C3 when expressed at % of the total protein and also as % of the total protein less gamma-globulins of the CSF. Other parameters of the CSF are also recorded. It was shown that only the expression of C3 concentration relative to the total protein content of the CSF produced meaningful analytical data.

Complement C3↗

Ocular bioavailability and systemic loss of topically applied ophthalmic drugs.

We used 20-day-old rabbits as a model to show that the ocular bioavailability of topically applied pilocarpine nitrate increased as the instilled volume of the drug was decreased. Decreasing the instilled volume from 25 to 5 microliter permitted a dosage reduction of greater than 2.5 times without sacrificing overall drug concentrations in the eye. Since only a small fraction of topically applied doses to the eye actually reached the interior of the eye, the remainder of the dose was lost and available for systemic absorption. The reduction in dosage permitted by this approach resulted in less drug appearing in the general circulation, as shown by comparative plasma level-time profiles. The advantages of reducing drop size are improved ocular bioavailability permitting the use of smaller doses; and less systemic drug loss, thus reducing the potential for systemic side effects. These advantages could be especially significant in the pediatric and geriatric age groups.

Administration, Topical↗

[Selective deficiencies of phagocytosis and opsonization towards Staphylococcus aureus. 1. Preliminary study in normal humans and patients with debilitating diseases].

We studied simultaneously the bactericidal activity (BA) and the serum opsonic capacity (OC) towards S. aureus and Escherichia coli during 2 hours of phagocytosis in vitro. The PMNs and the sera from 17 seriously ill patients and from 10 normal individuals were tested. Both BA and OC towards E. coli were the same for all patients and controls. The BA for one patient and the OC for three other patients were found to be diminished significantly. The last three patients had infectious complications due to S. aureus only. The selective deficiency of OC towards S. aureus in these three patients may be connected with the pathogenesis of their infectious complications.

Adolescent↗

Spontaneous dissociation of an IgG-3 paraprotein through disulfide interchange.

A paraprotein of the gamma3 subclass was observed to dissociate "spontaneously" under various experimental conditions, such as during chromatography on DEAE-cellulose and on Sephadex G-200 or on starch block electrophoresis. This phenomenon was accompanied by the formation of various complexes of higher molecular weight, displaying antigenic properties different from those of the original paraprotein. These changes did not occur in the presence of iodoacetamide, indicating that dissociation of the paraprotein was due to disulfide interchange(s) and not to the absence of interchain disulfide bridges.

Chromatography, DEAE-Cellulose↗