PubMed Health⌕ Search

Biomedical subjects

M Fuerst

Publications and source records attributed to M Fuerst.

10 recordsLinked to original sources

[Principles of fixation of the cementless modular revision stem Revitan].

AIM AND METHOD: To analyse the femoral fixation of a modular cementless revision endoprosthesis, eight prosthetic combinations of the Revitan-System (Centerpulse, Winterthur, Switzerland) were implanted in four cadavers. On three cadavers a curved revision Revitan stem was implanted by an endofemoral approach on one side and by a transfemoral approach on the contralateral side. On the fourth cadaver a straight Revitan stem was implanted on one side and a curved Revitan stem on the contralateral side using a transfemoral approach. Transversal slides of 7-8 mm thickness were performed at the fixation areas of each implant and the implant-bone contact was analysed macroscopically and using contact radiography. RESULTS: The straight stem implanted by a transfemoral approach showed a double-conical press-fit fixation with cutting of the eight longitudinal fins into the cortical bone. The curved revision stems implanted by the same approach had a circular surface fixation similar to the press-fit fixation of the straight stem. In contrast, the curved stems implanted by the endofemoral approach (without a window) showed a three-surface fixation. Hereby the two distal fixation areas led to the primary implant stability by three of the four double edges of the octagonal cross-sectional area cutting into the cortical bone. At the proximal fixation zone the implant only had contact of two implant double edges to the cortical bone. CONCLUSION: Different approaches for implantation lead to different fixation techniques of a curved revision stem. This should be considered by analysing postoperative sintering rates of cementless revision stems.

Aged↗

Risk analysis and safety assessment in surgical robotics: a case study on a biopsy robot.

One of the most important issues in medical robotics is safety and integration into the clinical workflow. If a robot is not safe and its use is complicated by difficult handling and complex user interfaces physicians would not use a robotic system during clinical patient trials, whatever the other advantages are. However, there are only few publications on this topic, in particular on risk management in developing a robotic prototype (for clinical trials). In this paper risk management and the safety of using robot-assisted surgery equipment are discussed and demonstrated exemplarily in the process of developing a prototype biopsy robot.

Journal Article↗

A web implementation: the good and the not-so-good.

E-commerce, e-mail, e-greeting, e-this, and e-that everywhere you turn there is a new "e" word for an internet or Web application. We, at the Cleveland Clinic Foundation, have been "e-nlightened" and will discuss in this report the implementation of a web-based radiology information system (RIS) in our radiology division or "e-radiology" division. The application, IDXRad Version 10.0 from IDX Corp, Burlington, VT, is in use at the Cleveland Clinic Foundation and has both intranet (for use in Radiology) and internet (referring physician viewing) modules. We will concentrate on the features of using a web browser for the application's front-end, including easy prototyping for screen review, easier mock-ups of demonstrations by vendors and developers, and easier training as more people become web-addicted. Project communication can be facilitated with an internal project web page, and use of the web browser can accommodate quicker turnaround of software upgrades as the software code is centrally located. Compared with other technologies, including client/server, there is a smaller roll out cost when using a standard web browser. However, the new technology requires a change and changes are never implemented without challenges. A seasoned technologist using a legacy system can enter data quicker using function keys than using a graphical user interface and pointing and clicking through a series of pop-up windows. Also, effective use of a web browser depends on intuitive design for it to be easily implemented and accepted by the user. Some software packages will not work on both of the popular web browsers and then are tailored to specific release levels. As computer-based patient records become a standard, patient confidentiality must be enforced. The technical design and application security features that support the web-based software package will be discussed. Also web technologies have their own implementation issues.

Computer Communication Networks↗

HIV-related diarrhea is multifactorial and fat malabsorption is commonly present, independent of HAART.

OBJECTIVE: Highly active antiretroviral therapy (HAART) has significantly decreased the incidence of infectious diarrhea affecting HIV-infected patients. Still, diarrhea remains a common symptom in HIV. We sought to determine the incidence of fat malabsorption as a cause of diarrhea in HIV patients receiving non-HAART (nucleoside analog only) and HAART (protease inhibitor-containing) antiretroviral regimens. METHODS: From June, 1995, to April, 1999, 88 HlV-infected patients underwent evaluation for diarrhea, which included endoscopy. We examined the incidence of fat malabsorption with a 24-h stool collection for fecal fat in a cohort of these patients (N = 33). Patients were divided into two groups, those receiving protease inhibitor-containing HAART and those receiving less intensive, nucleoside analog-only, non-HAART regimens. RESULTS: Thirty of 33 patients (90.9%) had fat malabsorption. Twenty of 21 patients not receiving HAART (95.2%) had fat malabsorption with a mean of 34 +/- 38 g of stool fat and a mean stool weight of 797 +/- 454 g. Ten of 12 patients receiving HAART (83.3%) had fat malabsorption with a mean of 46 +/- 86 g of stool fat and a mean stool weight of 800 +/- 647 g. Stool weight correlated with the degree of fat malabsorption (R = 0.77). CONCLUSION: Fat malabsorption represents a commonly undiagnosed entity in HIV-infected patients with diarrhea, whether or not they are receiving HAART therapy. Fecal fat determination should be considered a routine part of the diagnostic workup of HIV-infected patients experiencing diarrhea.

AIDS-Related Opportunistic Infections↗

The promotion has gone high-tech; the results haven't.

Where the legendary charlatan used showmanship to sell his snake oil, today's promoter of unorthodox medicine uses science. Many are scientifically trained yet are reluctant to put their wares to a clinical trial--a gap that leaves physicians who specialize in ferreting out fraud saying it may be nothing but high-tech hokum.

Commerce↗

Mending fences.

Explore the source record for details and available documents.

Physician-Patient Relations↗

[The value of preoperative knee aspiration and arthroscopic biopsy in revision total knee arthroplasty].

AIM: The accurate preoperative diagnosis of occult sepsis in endoprosthetic loosening of total knee arthroplasty is the key to successful management of revision total knee arthroplasties. The aim of this study was to evaluate the results of preoperative aspiration in comparison with preoperative arthroscopic biopsy of the synovial tissue. METHOD: From 2000 to 2004 eighty-six revision total knee arthroplasties in 86 patients were performed. 60 patients had only a knee aspiration, 15 an arthroscopic biopsy and an aspiration, 11 only arthroscopic biopsy. The results of both methods were compared with the intraoperative cultures during revision surgery. RESULTS: 69 aseptic and 17 septic knee exchange arthroplasties were performed. The preoperative aspiration of the prosthetic knee joint had a sensitivity of 68.8 %, specificity of 96.6 %, positive predictive value of 84.5 % and a negative predictive value of 92.2 %. The preoperative arthroscopic biopsy had a sensitivity of 100 %, specificity of 94.7 %, positive predictive value of 87.4 % and a negative predictive value of 100 %. CONCLUSION: Preoperative aspiration of the knee is a very helpful study for the diagnosis or exclusion of infection in a prosthetic knee joint and should be a standard procedure in the diagnosis of prosthetic loosening. If after aspiration a suspicion of infection remains, then the biopsy is an accurate procedure to diagnose or exclude periprosthetic sepsis.

Aged↗