PubMed Health⌕ Search

Biomedical subjects

M Funovics

Publications and source records attributed to M Funovics.

16 recordsLinked to original sources

[Optical imaging of fluorescence in the near infrared. From passive to enzymatically activated contrast medium].

The molecular imaging of specific targets using optical methods is currently possible in vivo, in part due to the advances in imaging modalities (epifluorescence, fluorescent endoscopy, fluorescence mediated tomography, intravital fluorescence microscopy), and in part due to the development of better contrast media. These are composed of a suitable fluorochrome, usually with emission in the near infrared due to tissue penetration, as well as by molecular specific contrast media from ligands. The latest generation of contrast media is not fluorescent in its unactivated state. Fluorescence first occurs after contact with certain (e.g. disease specific) enzymes by which a minimally unspecific fluorescent background as well as molecular specificity is made possible.

Biomarkers↗

[Diagnosis of intraocular foreign bodies in multidetector-CT: influence of acquisition parameters on radiation dose and detectability].

PURPOSE: Determination of the influence of acquisition and reconstruction parameters on radiation dose and detectability of intraocular foreign bodies using multidetector CT (MDCT). MATERIALS AND METHODS: Porcine eyes with intraocular foreign bodies of a 0.3-mm quartz fiber and a 0.1-mm steel wire as well as 0.5 ml of blood in the vitreous were investigated using MDCT. The tube current was 500, 250, 100, and 50 mAs; the collimation was 16 x 0.75 mm and 16 x 1.5 mm; and the pitch was 0.5 and 0.75. Image reconstruction was performed using a soft tissue (H30), a bone algorithm (H60 s), and thin (0.7 and 2 mm, respectively) and thick (2 and 4 mm, respectively) reconstruction increments. The resulting data sets were then used to determine the signal difference to noise ratio (SDNR) between the foreign body and adjacent vitreous. RESULTS: Changes in tube current resulted in a proportional change in the radiation dose but only in the SDNR within a range of 1:2. Reducing the collimation from 1.5 mm to 0.75 mm resulted in a doubling of the SDNR at an approximately identical radiation dose. The series with a lower pitch at the same dose per volume showed a slightly higher SDNR. Reconstruction using a bone algorithm and thin increments resulted in an increase in the mean SDNR by a factor of 1.8 to 2.3. CONCLUSION: When diagnosing small intraocular foreign bodies using MDCT, the following parameters can yield an adequate SDNR while minimizing radiation exposure: tube current 50 mAs, pitch 0.5, collimation 16 x 0.75, bone algorithm, and reconstruction increment 0.7 mm.

Animals↗

Ultrasound-guided percutaneous ethanol ablation of parathyroid hyperplasia: preliminary experience in patients on chronic dialysis.

OBJECTIVE: We report on a 3-year experience using single-shot, ultrasonography-guided, percutaneous ethanol ablation (PEA) of hyperplastic parathyroid glands in chronic dialysis patients suffering from secondary or tertiary hyperparathyroidism. MATERIALS AND METHODS: Seventeen uraemic patients (mean age 52 +/- 14 years) with hypercalcaemia and elevated serum levels of parathyroid hormone were assessed for ethanol ablation. Ten patients did not fulfil the inclusion criteria and underwent surgical parathyroidectomy. Seven patients were treated using PEA. RESULTS: All patients treated with PEA tolerated the procedure well, and no major complications were observed. Three out of seven patients underwent further ethanol ablation due to recurrent symptomatic hyperparathyroidism. Following the procedures, serum values of total calcium and parathyroid hormone remained within target range with concomitant medical therapy in all patients. CONCLUSION: PEA performed as a single-shot therapy can be used as a minimally invasive and safe supplement to medical therapy in the treatment of secondary or tertiary hyperparathyroidism in selected patients. In case of recurrence, treatment can be repeated without any problems.

Adult↗

Shortening of the patellar tendon length does not influence the patellofemoral alignment in a cadaveric model.

INTRODUCTION: Anterior cruciate ligament (ACL) reconstruction with the use of autograft tissue represents the standard treatment. The use of a bone-patellar tendon-bone transplant for symptomatic ACL deficiency achieves good long-term results. The purpose of the study was to investigate in a cadaveric model whether reproducible patellar tendon shortening changes the patellofemoral alignment. MATERIALS AND METHODS: Using five cadaveric knees, an MRI investigation was performed with the patellar tendon left unchanged, shortened 5 mm and shortened 10 mm, respectively, in both 20 and 45 degrees of knee flexion. The lateral patellofemoral and the congruence angles were measured and compared using a one-way analysis of variance for repeated measurements. RESULTS: Shortening the patella tendon by approximately 20% did not significantly influence the patellofemoral alignment. CONCLUSION: Although anterior cruciate ligament-reconstruction using the patellar tendon has become a standard procedure, postoperative problems such as anterior knee pain, and patellofemoral osteoarthritis occur quite often. In this cadaver study we did not find a significant difference for the patellofemoral alignment, irrespective of the patellar tendon length.

Adult↗

[Temporary and permanent vena cava filter for prevention of pulmonary embolism].

Inferior vena cava filters have been used for prophylaxis of pulmonary embolism since the end of the sixties. Complication rates depend on the types of filters used and are reported to be 2% with the Guenther-Filter and 21% with the Titanium-Greenfield-Filter. Depending on the exact indication both filter types are useful instruments for the prevention of pulmonary embolism.

Equipment Design↗

[Evaluation of a computer-assisted diagnosis system in breast carcinoma].

PURPOSE: Evaluation of a computerassisted diagnosis (CAD) system (R2 linage Checker 1.2). Comparison of the results of three readers with and without knowledge of the computer results. MATERIALS AND METHODS: The mammograms of 52 patients, bilaterally in two planes each, with histologically proven carcinoma of the breast were included in the study. They were first scanned by the CAD machine and subsequently read by three readers with different degrees of experience in two sessions with and without knowledge of the computer results. RESULTS: Of the 91 views of carcinomas, the readers detected 96%, 89%, and 85%, respectively. With CAD, the values rose to 97%, 93%, and 96%. The increase of the first observer was not significant. As for the 49 areas of malignant microcalcifications, the first reader showed a significant decrease of sensitivity, the other two readers showed no significant change. The sensitivity of CAD was 74% for masses and 86% for microcalcifications at a rate of 1.8 false positive markers per image. All but two tumors were correctly marked in at least one plane. CONCLUSIONS: Use of the CAD machine led to a significant increase of sensitivity in the detection of malignant masses by two of three observers. In the case of malignant microcalcifications, and for the most experienced observer, CAD did not improve the results. The most important problem is the high rate of false positive markers.

Breast Neoplasms↗

[Endoanal magnetic resonance tomography in fecal incontinence].

PURPOSE: Within the recent years several studies have been performed to determine the value of endoanal magnetic resonance imaging (MRI) in faecal incontinence. METHODS: MRI is performed using a 0.5-1.5 T unit. A surface coil with a maximum diameter of 19 mm is placed in the anal canal. T2* 3D gradient-echo-sequences and T2-weighted turbo-spin-echo sequences in coronal, axial und sagittal orientation are acquired. RESULTS: Compared to endoanal ultrasound (EUS), which is the gold standard for diagnosis in faecal incontinence, endoanal MRI is better in visualization of the external sphincter. The accurate delineation of the external sphincter has led to the possibility to evaluate sphincter atrophy. Preliminary results have shown, that endoanal MRI has an accuracy of 90-95% in the demonstration of lesions in the external sphincter. In detection of lesions of the internal sphincter EUS is still superior to endoanal MRI. CONCLUSION: EUS and endoanal MRI are currently the optimal imaging techniques for faecal incontinence, with the advantage of detecting external sphincter atrophy with endoanal MRI.

Anal Canal↗

[Preoperative staging of colorectal carcinoma].

Carcinoma of the colorectum is one of the most frequent neoplasias, with an incidence of 40 in 100,000. For the effective use of new, differentiated, less invasive treatment options, exact preoperative staging of the tumor is essential. The introduction of endosonography in rectal tumor staging allows for exact differentiation of the rectal wall layers and thus of tumor stages 1-3 with median accuracy of 89%. Magnetic resonance imaging of the rectum, especially in double-contrast technique, can also be employed in high and stenosing tumors and leads to an average accuracy of 85% for the stages 1-4. Computed tomography is the method of choice in screening for metastases. In lymph node staging, all modalities show only moderate accuracy around 75%.

Colon↗

[Staging of musculoskeletal tumors in diagnostic imaging].

The staging of primary malignant bone and soft tissue tumors requires adherence to a unified staging system. The staging system of the American Joint Commission for Cancer, the Enneking system, and the Hajdu system are described in respect of the radiologic staging criteria. Plain film radiography can estimate the biological aggressiveness of a bone tumor and in many cases narrow the differential diagnosis. Computed tomography is most sensitive in depicting cortical erosions and calcified periosteal reactions as well as in screening for distant metastasis. Angiography is mainly employed for vascular tumors and for the monitoring of interventional procedures such as tumor embolization. For both bone and soft tissue tumors, magnetic resonance tomography is the method of choice for the staging of intra- and extramedullary tumor extension, for the differentiation of neighboring compartments, and in the detection of invasion of the regional neurovascular bundle. After administration of contrast agents, the mode of enhancement gives further information on the nature of the tumor. With consistent application of the staging criteria in preoperative imaging, limb-saving therapy can be employed more often and the prognosis of the disease can be improved.

Bone Neoplasms↗

Quiz case 10. Metastasising retroduodenal gastrinoma.

A 37-year-old male patient with no significant past medical history presented with a 6-month history of intermittent epigastric pain which was partially relieved by antacid medication. Gastroscopy showed a peptic ulcer and the biopsies that were taken did not show signs of malignancy. Conservative treatment was initiated, but healing was prolonged, and the epigastric pain persisted. The patient was referred to our department for further diagnosis.

Adult↗

Patellar alignment evaluated by MRI.

We analyzed the congruence of the articular cartilage surfaces and the corresponding subchondral bone in the patellar joint. 20 volunteers underwent MRI investigations of the right patellar joint in 20 degree and 45 degree flexion in the axial plane. The sulcus, congruence, and lateral patellofemoral angles, measured on MRI slices centered through the midtransverse patella, were recorded. In 20 degree and 45 degree knee flexion, the bony sulcus and lateral patellofemoral angles were significantly different from the respective cartilagineous angle. We conclude that 1) measurement of the bony sulcus and lateral patellofemoral angles does not allow conclusions about the articular cartilage surface and its thickness, 2) the bony congruence angle corresponds well to the articular cartilage surface as an indicator of patellar centralization.

Anthropometry↗

[Computer-assisted diagnosis in mammography: the R2 ImageChecker System in detection of spiculated lesions].

Because of the rapid development of computer systems for digitalization and image analysis, they play an increasing important role in computer-assisted diagnosis (CAD). Especially in the field of mammography, the early signs of malignancy are relatively uniform and therefore more easily detected by a computer algorithm. In this study, we tested one of the few commercially available systems for the detection of both microcalcifications and suspicious, spiculated solid lesions on 40 cases of proven breast carcinomas. These mammograms were analyzed by three independent observers with and without knowledge of the computer results, respectively. Depending on the time of their radiologic experience, the sensitivity of the observers alone was 92.4%, 86.1% and 82%. With knowledge of the computer interpretation, sensitivity of all three observers rose significantly to 100%, 92.7%, and 95%, respectively. However, due to a high number of false positive results of the computer algorithm (0.4 markers per image), the positive predictive value of the interpretations worsened from 100%, 92.7%, and 95.5% to 86.4%, 97.3%, and 91.1%, respectively. It can be expected that future developments will soon overcome this problem and CAD will become an effective tool in screening mammography.

Adult↗

PTA versus carbofilm-coated stents in infrapopliteal arteries: pilot study.

PURPOSE: To determine the primary success and short-term patency of stent application as a primary treatment modality for high-grade lesions of the infrapopliteal arteries compared with treatment with percutaneous transluminal angioplasty (PTA) in critical limb ischemia in a randomized prospective study. METHODS: Endovascular therapy was performed on 95 lesions in 51 patients (mean age 72.0 years, range 47-80 years) who presented clinically with Fontaine stages III and IV. One patient underwent treatment in both limbs. After angiographic lesion identification, patients were randomized for treatment by PTA (53 lesions in 27 patients) or stent application (42 lesions in 24 patients). Follow-up by clinical investigation and conventional angiography or spiral CT angiography was performed in 37 patients (57 lesions) 6 to 12 months after the procedure, or when clinically indicated. Evaluation was performed by two observers, double-blinded, with thresholds for lesion restenosis of 50% and 70%. Statistical evaluation was performed on a lesion basis by Kaplan-Meier estimated probability rates, and log-rank and Wilcoxon tests. The primary endpoint was the angiographic patency rate of treated lesions. RESULTS: The inter-reader agreement was high (kappa = 0.82). For the stent group the cumulative primary patency at 6 months was 83.7% at the 70% restenosis threshold, and 79.7% at the 50% restenosis threshold. For PTA, the primary patency at 6 months was 61.1% at the 70% restenosis threshold and 45.6% at the 50% restenosis threshold. Both results were statistically significant (p < 0.05). CONCLUSION: Infrapopliteal stent application is an effective treatment modality for high-grade lesions in chronic critical limb ischemia. Compared with PTA, higher patency rates can be expected after 6 months.

Aged↗

Open meniscal repair: clinical and magnetic resonance imaging findings after twelve years.

The purpose of this study was to document the longterm clinical, radiographic, and magnetic resonance imaging results after open meniscal repair. Twenty-two patients, with 23 open meniscal repairs, were evaluated after a mean follow-up of 12.9 years using patient history, physical examination, KT-1000 arthrometer testing, the "Orthopaedische Arbeitsgemeinschaft Knie" knee evaluation scheme, Tegner activity score, weightbearing radiographs, and magnetic resonance imaging. Two of the 22 patients had retears and both occurred in unstable knees. Radiographs revealed no degenerative changes in 17 of the 23 compartments. Grade III and IV signal alterations were present on magnetic resonance imaging scans in more than 50% of the repaired menisci. We concluded that the longterm survival rate of repaired menisci was 91%, and that magnetic resonance imaging is unsuitable for diagnosis of the healing process of a repaired meniscus.

Adult↗