PubMed Health⌕ Search

Biomedical subjects

M G Carolan

Publications and source records attributed to M G Carolan.

7 recordsLinked to original sources

Planar versus SPET imaging in the assessment of condylar growth.

The aim of this study was to compare two methods of quantifying 99Tc(m)-methylene diphosphonate uptake in the mandibular condyle. The study groups consisted of 23 patients with mandibular asymmetry and 16 normal volunteers aged 10-30 years. The accuracy and reproducibility of SPET using condyle-to-clivus ratios was compared with planar analysis using condyle-to-L4 (fourth lumbar vertebra) ratios. Quantitative analysis was correlated with semi-quantitative grading by three observers. Normal ranges for condyle-to-L4 and condyle-to-clivus ratios in individuals aged 11 years or over were determined. These ratios are useful in the serial monitoring of patients with condylar hyperplasia to establish when condylar growth has ceased and hence the type of surgery performed. Visual interpretation of condylar activity should use a combination of planar and SPET images and be performed in conjunction with quantitative analysis. Semi-quantitative grading on SPET images detected more subtle differences in condylar activity than planar images (using quantitative analysis as a standard).

Adolescent↗

Improved spatial resolution by MOSFET dosimetry of an x-ray microbeam.

Measurement of the lateral profile of the dose distribution across a narrow x-ray microbeam requires a dosimeter with a micron resolution. We investigated the use of a MOSFET dosimeter in an "edge-on" orientation with the gate insulating oxide layer parallel to the direction of the beam. We compared results using this technique to Gafchromic film measurements of a 200 micrometer wide planar x-ray microbeam. The microbeam was obtained by using a vernier micrometer-driven miniature collimator attached to a Therapax DXT300 x-ray machine operated at 100 kVp. The "edge-on" application allows utilization of the ultra thin sensitive volume of the MOSFET detector. Spatial resolution of both the MOSFET and Gafchromic film dosimeters appeared to be of about 1 micrometer. The MOSFET dosimeter appeared to provide more uniform dose profiles with the advantage of on-line measurements.

Biophysical Phenomena↗

Dosimetry of blood irradiation with radiochromic film.

It has been shown that radiochromic film is an ideal dosimeter for assessment and verification of delivered dose to irradiated blood products. Using a parallel opposing two-field technique on a medical linear accelerator, blood is irradiated to diminish the risk of transfusion-associated graft vs. host disease (TA-GVHD). The blood products are irradiated in a Perspex blood box to an applied dose of 29.5-31.7 Gy. Verification of applied dose has been performed with thimble ionization chambers and radiochromic film. Radiochromic film results have matched absorbed dose measurements from ionization chambers at all sites within the 'active' treatment volume within +/-6% for a 95% confidence limit. Using a sample of 100 in-vitro measurements, radiochromic film has measured the average applied dose to blood products to be 30.95+/-2.6 Gy for two standard deviations. Like currently available 'irradiated' film labels, the radiochromic film also serves as a visible reminder that the blood products have been irradiated.

Blood↗

Retropharyngeal abscess on a Ga-67 scan: a case report.

A retropharyngeal abscess is a potentially fatal deep neck infection. Classical symptoms include fever, neck swelling, sore throat, dysphagia, and cervical rigidity. Sometimes small children present with nonspecific symptoms. We report a rare case whereby the Ga-67 citrate scan was the first investigation to reveal an inflammatory process in the retropharyngeal or submastoid region of a 3-year-old child with sepsis. This directed the line of investigation to a more precise anatomic imaging modality, CT scanning, to localize the abscess. With prompt administration of intravenous antibiotics, the child recovered quickly and did not require surgery. The Ga-67 scan is thus a useful screening test to detect inflammatory foci because of its high sensitivity. It is also valuable in the follow-up of the patient's response to therapy.

Anti-Bacterial Agents↗

Conversion of an infrared densitometer for radiochromic film analysis.

By the simple incorporation of a high intensity red LED into a typical infrared film densitometer, radiochromic film can be analysed using existing detectors and scanning software. Results show an accurate dose measurement using radiochromic film and this system compared to conventional detectors for percentage depth dose and penumbral measurements in high and low energy x-ray beams. A small circuit including a red Light Emitting Diode (LED) was positioned inside the film densitometer which does not obscure the infrared source. The red and infrared diodes work independently. For 6 MV x-rays, the 80%/20% penumbral width at 15 mm depth for a 10 x 10 cm field at 100 cm SSD was measured to be 3.5 mm with radiochromic film as compared to 3.3 with corrected diode measurements. Percentage depth doses were measured to within +/- 3% of ionisation chamber data at 6MV and within +/- 2% for 250 kVp x-ray with the film placed parallel to the beam direction in both cases.

Absorptiometry, Photon↗