PubMed Health⌕ Search

Biomedical subjects

M G Pomper

Publications and source records attributed to M G Pomper.

20 records · Page 2Linked to original sources

21-[18F]fluoro-16 alpha-ethyl-19-norprogesterone: synthesis and target tissue selective uptake of a progestin receptor based radiotracer for positron emission tomography.

We have synthesized 21-[18F]fluoro-16 alpha-ethyl-19-norprogesterone (FENP), a high affinity ligand for the progesterone receptor, labeled with the positron-emitting radionuclide fluorine-18 (t1/2 = 110 min). The synthesis proceeds in two steps from 21-hydroxy-16 alpha-ethyl-19-norprogesterone and involves [18F]fluoride ion displacement of the 21-trifluoromethanesulfonate (21-triflate). This material is purified by HPLC and is obtained in 4-30% overall yield (decay corrected) within 40 min after the end of bombardment to produce [18F]fluoride ion. The effective specific activity, determined by competitive radioreceptor binding assays, is 700-1400 Ci/mmol. In vivo, [18F]FENP demonstrates highly selective, receptor-mediated uptake by the uterus of estrogen-primed rats; the uterus to blood and uterus to muscle ratios were respectively 26 and 16 at 1 h and 71 and 41 at 3 h after injection. The high target tissue selectivity of this uptake suggests that this compound may be useful for the in vivo imaging of progestin target tissues and receptor-rich tumors (such as human breast tumors) by positron emission tomography.

Animals↗

Quantification and minimization of magnetic susceptibility artifacts on GRE images.

PURPOSE: The purpose of this work was to determine the optimal imaging parameters for minimization of metallic susceptibility artifacts during gradient echo (GRE) imaging. METHOD: We performed GRE imaging of titanium screws in a nickel-doped agarose gel phantom, systematically varying several parameters to characterize and quantify susceptibility artifacts. RESULTS: The greatest reduction in artifact size came from using a short TE; increasing the frequency matrix and decreasing the slice thickness also contributed substantially to reducing the artifact size. Whenever possible, implanted prostheses should be aligned with the main magnetic field to minimize artifact size. Parameters with negligible effect on artifact size included bandwidth, phase encode matrix, and field of view. CONCLUSION: Radiologists can easily adjust the above parameters in their imaging protocols to improve GRE image quality in patients with implanted metallic devices.

Artifacts↗